{"paper":{"title":"Saturated nucleate pool boiling of oxygen under magnetically-enhanced effective gravity","license":"","headline":"","cross_cats":[],"primary_cat":"cond-mat.soft","authors_text":"D. M. Strayer, M. E. Turk, N.-C. Yeh, N. N. Asplund, T. A. Corcovilos","submitted_at":"2007-02-01T08:54:11Z","abstract_excerpt":"We investigate the effect of enhancing gravity on saturated nucleate pool boiling of oxygen for effective gravities of 1g, 6.0g, and 16g (g=9.8 m/s^2) at a saturation pressure of 760 torr and for heat fluxes of 10 ~ 3000 W/m^2. The effective gravity on the oxygen is increased by applying a magnetic body force generated by a superconducting solenoid. We measure the heater temperature (expressed as a reduced superheat) as a function of heat flux and fit this data to a piecewise power-law/linear boiling curve. At low heat flux (<400 W/m^2) the superheat is proportional to the cube root of the hea"},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"cond-mat/0702012","kind":"arxiv","version":1},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/cond-mat/0702012/integrity.json","findings":[],"available":true,"detectors_run":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938"},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"}