{"paper":{"title":"Electric field compensation and sensing with a single ion in a planar trap","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"","cross_cats":["physics.ins-det","quant-ph"],"primary_cat":"physics.atom-ph","authors_text":"Ferdinand Schmidt-Kaler, Frank Ziesel, Hartmut H\\\"affner, Kilian Singer, Nikos Daniilidis, Rob Clark, Sankaranarayanan Selvarajan, S\\\"onke M\\\"oller","submitted_at":"2011-06-10T06:08:56Z","abstract_excerpt":"We use a single ion as an movable electric field sensor with accuracies on the order of a few V/m. For this, we compensate undesired static electric fields in a planar RF trap and characterize the static fields over an extended region along the trap axis. We observe a strong buildup of stray charges around the loading region on the trap resulting in an electric field of up to 1.3 kV/m at the ion position. We also find that the profile of the stray field remains constant over a time span of a few months."},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"1106.2730","kind":"arxiv","version":1},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"}