{"paper":{"title":"Statistical determinations of the gating windows in the respiratory gated radiotherapy using the visible guiding system","license":"http://creativecommons.org/licenses/by/3.0/","headline":"","cross_cats":[],"primary_cat":"physics.med-ph","authors_text":"Hyun Jeong Lee, Ji Woon Yea, Se An Oh, Sung Kyu Kim","submitted_at":"2015-05-11T05:24:10Z","abstract_excerpt":"Purpose: Respiratory gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung cancer patients. Determinations of the gating window in the respiratory phase of patients are important in RGRT but it is not easy. The objective of this study was to determine the optimal gating window with a visible guiding system in RGRT.\n  Materials and Methods: Between April and October in 2014 the breathing signals of 23 lung cancer patients were recorded with a Real-time Position Management (RPM) respiratory gating system (Varian, USA). We performed statistical analysis wi"},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"1505.02485","kind":"arxiv","version":2},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"}