{"paper":{"title":"nu_e Disappearance in MiniBooNE","arxiv_id":"0707.4593","primary_cat":"hep-ph","submitted_at":"2007-07-31T13:23:22+00:00","version_compiled":"v3"},"notice":"Every quoted sentence is the authors' text from the arXiv listing abstract. Labels and probabilities are the outputs of classifier-1.13-20260917 on the question bank abstract-p1-20260923, exactly as returned. No sentence in this record was written by a language model.","schema":"pith.compiled-record/v0","status":"compiled","abstract":{"source":"arXiv listing abstract v3","sentences":[{"i":0,"p":0.84,"id":"s0","own":true,"role":"interpretation","text":"The anomalous excess of low-energy nu_e events measured in the MiniBooNE experiment is explained through a renormalization of the absolute neutrino flux and a simultaneous disappearance of the nu_e's in the beam, which is compatible with that indicated by the results of Gallium radioactive source experiments.","hedge":{"p":0.93,"label":"asserted"},"own_p":0.53,"main_claim_p":0.84,"quantitative":false,"quantitative_p":0.19,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.1,"background":0.01,"limitation":0.0,"future_work":0.0,"contribution":0.05,"interpretation":0.84}},{"i":1,"p":0.98,"id":"s1","own":true,"role":"result","text":"We present the results of the fit of MiniBooNE data (P(nu_e->nu_e) = 0.64 +0.08 -0.07) and the combined fit of MiniBooNE data and the nu_e disappearance measured in the Gallium radioactive source experiments, which gives P(nu_e->nu_e) = 0.82 +- 0.04.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.93,"main_claim_p":0.3,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.98,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.02,"interpretation":0.0}},{"i":2,"p":0.73,"id":"s2","own":true,"role":"result","text":"We show that our interpretation of the data is also compatible with an old indication in favor of nu_e disappearance found from the analysis of the results of beam-dump experiments, leading to P(nu_e->nu_e) = 0.80 +0.03 -0.04.","hedge":{"p":0.85,"label":"asserted"},"own_p":0.55,"main_claim_p":0.11,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.73,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.03,"interpretation":0.24}}]},"compiled":{"main_claim":{"p":1.0,"text":"The anomalous excess of low-energy nu_e events measured in the MiniBooNE experiment is explained through a renormalization of the absolute neutrino flux and a simultaneous disappearance of the nu_e's in the beam, which is compatible with that indicated by the results of Gallium radioactive source experiments.","location":"abstract s0","hedge_strength":{"p":0.93,"label":"asserted"}},"provenance":{"route":{"via":"OpenRouter","model":"classifier-1.13","endpoint":"https://openrouter.ai/api/v1/systemone","provider":"TypeSafe"},"packing":"one request per paper","requests":1,"input_tokens":3285,"cost_usd_reported":0.000138},"compiled_at":"2026-09-23","bank_version":"abstract-p1-20260923","model_version":"classifier-1.13-20260917","abstract_states":{"claims_first":0.03,"states_limitation":0.13,"human_participants":0.02,"controlled_comparison":0.16,"randomized_assignment":0.01,"states_quantitative_result":0.99,"compares_with_prior_results":0.96,"mentions_code_or_data_availability":0.02},"evidential_basis":{"p":1.0,"value":"analysis of existing data","probabilities":{"argument":0.0,"literature":0.0,"proof_or_derivation":0.0,"analysis_of_existing_data":1.0,"observation_or_experiment":0.0,"simulation_or_computation":0.0}},"contribution_type":{"p":0.46,"value":"empirical study","probabilities":{"review":0.0,"method_or_tool":0.0,"empirical_study":0.46,"simulation_study":0.02,"theoretical_result":0.25,"dataset_or_benchmark":0.0,"position_or_commentary":0.27}},"contribution_statement":{"p":0.81,"text":"We present the results of the fit of MiniBooNE data (P(nu_e->nu_e) = 0.64 +0.08 -0.07) and the combined fit of MiniBooNE data and the nu_e disappearance measured in the Gallium radioactive source experiments, which gives P(nu_e->nu_e) = 0.82 +- 0.04.","location":"abstract s1"}},"coverage":{"tier":"abstract","levels_run":["P abstract"],"not_examined":["full text","figures and tables","references and citing sentences","relations to other papers"],"sources_read":["arXiv listing abstract v3"],"levels_not_run":["S sections","T body sentences","C citations","R cross-paper relations"],"sentences_examined":3,"sentences_in_abstract":3},"measured_accuracy":{"url":"https://pith.science/accuracy","measured_on":"2026-10-02","method":"two independent model families labelled a fresh random sample blind; the figure is how often the published label matches their consensus","sentence_role_agreement":0.92,"main_claim_agreement":0.908,"typed_citation_agreement":0.933,"typed_citation_agreement_95_interval":[0.917,0.945],"review_comments_accurate":0.758,"review_comments_accurate_95_interval":[0.684,0.82],"review_caught_admitted_error_found_or_related":0.448}}