{"paper":{"title":"Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at sqrt(s) = 7 TeV","arxiv_id":"1306.2016","primary_cat":"hep-ex","submitted_at":"2013-06-09T12:59:12+00:00","version_compiled":"v2"},"notice":"Every quoted sentence is the authors' text from the arXiv listing abstract. Labels and probabilities are the outputs of classifier-1.13-20260917 on the question bank abstract-p1-20260923, exactly as returned. No sentence in this record was written by a language model.","schema":"pith.compiled-record/v0","status":"compiled","abstract":{"source":"arXiv listing abstract v2","sentences":[{"i":0,"p":0.51,"id":"s0","own":true,"role":"method","text":"The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.94,"main_claim_p":0.08,"quantitative":true,"quantitative_p":0.97,"role_probabilities":{"gap":0.0,"method":0.51,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.49,"interpretation":0.0}},{"i":1,"p":0.79,"id":"s1","own":true,"role":"method","text":"Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented.","hedge":{"p":0.92,"label":"asserted"},"own_p":0.6,"main_claim_p":0.03,"quantitative":false,"quantitative_p":0.03,"role_probabilities":{"gap":0.0,"method":0.79,"result":0.0,"background":0.01,"limitation":0.0,"future_work":0.0,"contribution":0.2,"interpretation":0.0}},{"i":2,"p":0.98,"id":"s2","own":true,"role":"method","text":"The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector.","hedge":{"p":0.96,"label":"asserted"},"own_p":0.72,"main_claim_p":0.03,"quantitative":false,"quantitative_p":0.04,"role_probabilities":{"gap":0.0,"method":0.98,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.02,"interpretation":0.0}},{"i":3,"p":1.0,"id":"s3","own":true,"role":"result","text":"The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity abs(eta)<0.8) and is 2-5% elsewhere.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.94,"main_claim_p":0.27,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":4,"p":1.0,"id":"s4","own":true,"role":"result","text":"The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the endcaps.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.94,"main_claim_p":0.13,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":5,"p":0.99,"id":"s5","own":true,"role":"result","text":"The calibration of the absolute energy is determined from Z to e+e- decays to a precision of 0.4% in the barrel and 0.8% in the endcaps.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.95,"main_claim_p":0.18,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.01,"result":0.99,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}}]},"compiled":{"main_claim":{"p":0.47,"text":"The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns.","location":"abstract s0","hedge_strength":{"p":1.0,"label":"asserted"}},"provenance":{"route":{"via":"OpenRouter","model":"classifier-1.13","endpoint":"https://openrouter.ai/api/v1/systemone","provider":"TypeSafe"},"packing":"one request per paper","requests":1,"input_tokens":5181,"cost_usd_reported":0.000218},"compiled_at":"2026-09-23","bank_version":"abstract-p1-20260923","model_version":"classifier-1.13-20260917","abstract_states":{"claims_first":0.02,"states_limitation":0.23,"human_participants":0.02,"controlled_comparison":0.03,"randomized_assignment":0.01,"states_quantitative_result":0.99,"compares_with_prior_results":0.07,"mentions_code_or_data_availability":0.02},"evidential_basis":{"p":0.59,"value":"observation or experiment","probabilities":{"argument":0.0,"literature":0.0,"proof_or_derivation":0.0,"analysis_of_existing_data":0.41,"observation_or_experiment":0.59,"simulation_or_computation":0.0}},"contribution_type":{"p":0.98,"value":"empirical study","probabilities":{"review":0.0,"method_or_tool":0.02,"empirical_study":0.98,"simulation_study":0.0,"theoretical_result":0.0,"dataset_or_benchmark":0.0,"position_or_commentary":0.0}},"contribution_statement":{"p":0.83,"text":"The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns.","location":"abstract s0"}},"coverage":{"tier":"abstract","levels_run":["P abstract"],"not_examined":["full text","figures and tables","references and citing sentences","relations to other papers"],"sources_read":["arXiv listing abstract v2"],"levels_not_run":["S sections","T body sentences","C citations","R cross-paper relations"],"sentences_examined":6,"sentences_in_abstract":6},"measured_accuracy":{"url":"https://pith.science/accuracy","measured_on":"2026-10-02","method":"two independent model families labelled a fresh random sample blind; the figure is how often the published label matches their consensus","sentence_role_agreement":0.92,"main_claim_agreement":0.908,"typed_citation_agreement":0.933,"typed_citation_agreement_95_interval":[0.917,0.945],"review_comments_accurate":0.758,"review_comments_accurate_95_interval":[0.684,0.82],"review_caught_admitted_error_found_or_related":0.448}}