{"paper":{"title":"Sensitivity of an antineutrino monitor for remote nuclear reactor discovery","arxiv_id":"2210.11224","primary_cat":"physics.ins-det","submitted_at":"2022-10-20T12:59:53+00:00","version_compiled":"v2"},"notice":"Every quoted sentence is the authors' text from the arXiv listing abstract. Labels and probabilities are the outputs of classifier-1.13.0 on the question bank abstract-p1-20260923, exactly as returned. No sentence in this record was written by a language model.","schema":"pith.compiled-record/v0","status":"compiled","abstract":{"source":"arXiv listing abstract v2","sentences":[{"i":0,"p":1.0,"id":"s0","own":false,"role":"background","text":"Antineutrinos from a nuclear reactor comprise an unshieldable signal which carries information about the core.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.06,"main_claim_p":0.03,"quantitative":false,"quantitative_p":0.03,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.0,"background":1.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":1,"p":0.38,"id":"s1","own":false,"role":"contribution","text":"A gadolinium-doped, water-based Cherenkov detector could detect reactor antineutrinos for mid- to far-field remote reactor monitoring for non-proliferation applications.","hedge":{"p":1.0,"label":"hedged_possibility"},"own_p":0.18,"main_claim_p":0.14,"quantitative":false,"quantitative_p":0.07,"role_probabilities":{"gap":0.0,"method":0.24,"result":0.01,"background":0.33,"limitation":0.0,"future_work":0.0,"contribution":0.38,"interpretation":0.04}},{"i":2,"p":0.52,"id":"s2","own":true,"role":"contribution","text":"Two novel and independent reconstruction and analysis pathways have been developed and applied to a number of representative reactor signals to evaluate the sensitivity of a kiloton-scale, gadolinium-doped Cherenkov detector as a remote monitor.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.94,"main_claim_p":0.07,"quantitative":false,"quantitative_p":0.44,"role_probabilities":{"gap":0.0,"method":0.48,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.52,"interpretation":0.0}},{"i":3,"p":0.91,"id":"s3","own":true,"role":"method","text":"The sensitivity of four detector configurations to nine reactor signal combinations was evaluated for a detector situated in Boulby Mine, close to the Boulby Underground Laboratory in the UK.","hedge":{"p":0.99,"label":"asserted"},"own_p":0.93,"main_claim_p":0.05,"quantitative":true,"quantitative_p":0.92,"role_probabilities":{"gap":0.0,"method":0.91,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.09,"interpretation":0.0}},{"i":4,"p":1.0,"id":"s4","own":true,"role":"result","text":"It was found that a 22~m detector with a gadolinium-doped, water-based liquid scintillator fill is sensitive to a $\\rm \\sim 3~GW_{th}$ reactor at a standoff of $\\rm \\sim150~km$ within two years in the current reactor landscape.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.94,"main_claim_p":0.74,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":5,"p":0.81,"id":"s5","own":true,"role":"interpretation","text":"A larger detector would be required to achieve a more timely detection or to monitor smaller or more distant reactors.","hedge":{"p":0.86,"label":"asserted"},"own_p":0.66,"main_claim_p":0.17,"quantitative":false,"quantitative_p":0.16,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.02,"background":0.0,"limitation":0.1,"future_work":0.06,"contribution":0.0,"interpretation":0.81}}]},"compiled":{"main_claim":{"p":0.91,"text":"It was found that a 22~m detector with a gadolinium-doped, water-based liquid scintillator fill is sensitive to a $\\rm \\sim 3~GW_{th}$ reactor at a standoff of $\\rm \\sim150~km$ within two years in the current reactor landscape.","location":"abstract s4","hedge_strength":{"p":1.0,"label":"asserted"}},"provenance":{"route":{"via":"TypeSafe API","model":"classifier-1.13.0","endpoint":"https://api.typesafe.ai/v1/systemone","provider":"TypeSafe"},"packing":"one request per paper","requests":1,"input_tokens":5058,"cost_usd_reported":0.0},"compiled_at":"2026-09-23","bank_version":"abstract-p1-20260923","model_version":"classifier-1.13.0","abstract_states":{"claims_first":0.05,"states_limitation":0.85,"human_participants":0.02,"controlled_comparison":0.07,"randomized_assignment":0.01,"states_quantitative_result":0.98,"compares_with_prior_results":0.15,"mentions_code_or_data_availability":0.02},"evidential_basis":{"p":0.99,"value":"simulation or computation","probabilities":{"argument":0.0,"literature":0.0,"proof_or_derivation":0.0,"analysis_of_existing_data":0.01,"observation_or_experiment":0.0,"simulation_or_computation":0.99}},"contribution_type":{"p":0.72,"value":"simulation study","probabilities":{"review":0.0,"method_or_tool":0.28,"empirical_study":0.0,"simulation_study":0.72,"theoretical_result":0.0,"dataset_or_benchmark":0.0,"position_or_commentary":0.0}},"contribution_statement":{"p":1.0,"text":"Two novel and independent reconstruction and analysis pathways have been developed and applied to a number of representative reactor signals to evaluate the sensitivity of a kiloton-scale, gadolinium-doped Cherenkov detector as a remote monitor.","location":"abstract s2"}},"coverage":{"tier":"abstract","levels_run":["P abstract"],"not_examined":["full text","figures and tables","references and citing sentences","relations to other papers"],"sources_read":["arXiv listing abstract v2"],"levels_not_run":["S sections","T body sentences","C citations","R cross-paper relations"],"sentences_examined":6,"sentences_in_abstract":6},"measured_accuracy":{"url":"https://pith.science/accuracy","measured_on":"2026-10-02","method":"two independent model families labelled a fresh random sample blind; the figure is how often the published label matches their consensus","sentence_role_agreement":0.92,"main_claim_agreement":0.908,"typed_citation_agreement":0.933,"typed_citation_agreement_95_interval":[0.917,0.945],"review_comments_accurate":0.758,"review_comments_accurate_95_interval":[0.684,0.82],"review_caught_admitted_error_found_or_related":0.448}}