{"paper":{"title":"Simulating The Urban Canopy's Impact on Wind-Driven Natural Ventilation","arxiv_id":"2508.04091","primary_cat":"physics.flu-dyn","submitted_at":"2025-08-06T05:19:19+00:00","version_compiled":"v3"},"notice":"Every quoted sentence is the authors' text from the arXiv listing abstract. Labels and probabilities are the outputs of classifier-1.13.0 on the question bank abstract-p1-20260923, exactly as returned. No sentence in this record was written by a language model.","schema":"pith.compiled-record/v0","status":"compiled","abstract":{"source":"arXiv listing abstract v3","sentences":[{"i":0,"p":0.99,"id":"s0","own":false,"role":"background","text":"The urban canopy affects wind in complex ways, making it challenging to predict wind-driven natural ventilation and cooling in buildings.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.06,"main_claim_p":0.06,"quantitative":false,"quantitative_p":0.03,"role_probabilities":{"gap":0.01,"method":0.0,"result":0.0,"background":0.99,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":1,"p":0.52,"id":"s1","own":true,"role":"method","text":"Using large eddy simulations of coupled outdoor and indoor airflow, we study how the surrounding urban canopy and wind angle influence ventilation rates through four ventilation configurations: cross, corner, dual-room, and single-sided.","hedge":{"p":0.9,"label":"asserted"},"own_p":0.97,"main_claim_p":0.05,"quantitative":true,"quantitative_p":0.53,"role_probabilities":{"gap":0.0,"method":0.52,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.48,"interpretation":0.0}},{"i":2,"p":0.99,"id":"s2","own":true,"role":"result","text":"Flow visualizations demonstrate how both large-scale flow patterns and local interference effects can influence ventilation rates by 50-85%.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.95,"main_claim_p":0.16,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.99,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.01}},{"i":3,"p":0.99,"id":"s3","own":true,"role":"result","text":"In general, lower density canopies give higher ventilation rates and wind angles that align with a direct path between two openings also lead to higher ventilation rates.","hedge":{"p":0.97,"label":"asserted"},"own_p":0.92,"main_claim_p":0.24,"quantitative":true,"quantitative_p":0.87,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.99,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.01}},{"i":4,"p":0.82,"id":"s4","own":true,"role":"result","text":"However, interference effects from surrounding buildings can significantly change the local wind speed and direction, thus also changing ventilation rates.","hedge":{"p":0.96,"label":"asserted"},"own_p":0.76,"main_claim_p":0.1,"quantitative":false,"quantitative_p":0.07,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.82,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.18}},{"i":5,"p":0.83,"id":"s5","own":true,"role":"result","text":"The magnitude of these interference effects depends on both the wind angle and surrounding building geometries.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.81,"main_claim_p":0.07,"quantitative":false,"quantitative_p":0.09,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.83,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.17}},{"i":6,"p":0.93,"id":"s6","own":true,"role":"result","text":"The effect of wind angle is less pronounced in a higher density canopy, where the urban canopy geometry more strongly guides the flow.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.9,"main_claim_p":0.09,"quantitative":true,"quantitative_p":0.92,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.93,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.07}},{"i":7,"p":0.94,"id":"s7","own":true,"role":"interpretation","text":"The results demonstrate that the canopy's effect on ventilation rates is much more complex than those suggested by existing natural ventilation parameterizations.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.87,"main_claim_p":0.78,"quantitative":true,"quantitative_p":0.59,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.06,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.94}}]},"compiled":{"main_claim":{"p":1.0,"text":"The results demonstrate that the canopy's effect on ventilation rates is much more complex than those suggested by existing natural ventilation parameterizations.","location":"abstract s7","hedge_strength":{"p":1.0,"label":"asserted"}},"provenance":{"route":{"via":"TypeSafe API","model":"classifier-1.13.0","endpoint":"https://api.typesafe.ai/v1/systemone","provider":"TypeSafe"},"packing":"one request per paper","requests":1,"input_tokens":6177,"cost_usd_reported":0.0},"compiled_at":"2026-11-13","bank_version":"abstract-p1-20260923","model_version":"classifier-1.13.0","abstract_states":{"claims_first":0.03,"states_limitation":0.18,"human_participants":0.02,"controlled_comparison":0.11,"randomized_assignment":0.01,"states_quantitative_result":0.98,"compares_with_prior_results":0.66,"mentions_code_or_data_availability":0.02},"evidential_basis":{"p":1.0,"value":"simulation or computation","probabilities":{"argument":0.0,"literature":0.0,"proof_or_derivation":0.0,"analysis_of_existing_data":0.0,"observation_or_experiment":0.0,"simulation_or_computation":1.0}},"contribution_type":{"p":1.0,"value":"simulation study","probabilities":{"review":0.0,"method_or_tool":0.0,"empirical_study":0.0,"simulation_study":1.0,"theoretical_result":0.0,"dataset_or_benchmark":0.0,"position_or_commentary":0.0}},"contribution_statement":{"p":1.0,"text":"Using large eddy simulations of coupled outdoor and indoor airflow, we study how the surrounding urban canopy and wind angle influence ventilation rates through four ventilation configurations: cross, corner, dual-room, and single-sided.","location":"abstract s1"}},"coverage":{"tier":"abstract","levels_run":["P abstract"],"not_examined":["full text","figures and tables","references and citing sentences","relations to other papers"],"sources_read":["arXiv listing abstract v3"],"levels_not_run":["S sections","T body sentences","C citations","R cross-paper relations"],"sentences_examined":8,"sentences_in_abstract":8},"measured_accuracy":{"url":"https://pith.science/accuracy","measured_on":"2026-10-02","method":"two independent model families labelled a fresh random sample blind; the figure is how often the published label matches their consensus","sentence_role_agreement":0.92,"main_claim_agreement":0.908,"typed_citation_agreement":0.933,"typed_citation_agreement_95_interval":[0.917,0.945],"review_comments_accurate":0.758,"review_comments_accurate_95_interval":[0.684,0.82],"review_caught_admitted_error_found_or_related":0.448,"review_comments_judged":{"judged_by":["gpt-5.6-luna","grok-4.7"],"judged_against":"Pith's own text copy of each paper: text extracted from the PDF, the first 90,000 characters","measured_on":"2026-10-04","accurate":113,"decided":149,"sampled_reviews":200,"split_by_lane":false,"by_lane":"https://pith.science/accuracy#by-lane"}}}