{"paper":{"title":"Laboratory and field testing of a residential heat pump retrofit for a DC solar nanogrid","arxiv_id":"2511.18267","primary_cat":"eess.SY","submitted_at":"2025-11-23T03:33:08+00:00","version_compiled":"v3"},"notice":"Every quoted sentence is the authors' text from the arXiv listing abstract. Labels and probabilities are the outputs of classifier-1.13.0 on the question bank abstract-p1-20260923, exactly as returned. No sentence in this record was written by a language model.","schema":"pith.compiled-record/v0","status":"compiled","abstract":{"source":"arXiv listing abstract v3","sentences":[{"i":0,"p":1.0,"id":"s0","own":false,"role":"background","text":"Residential buildings are increasingly integrating large devices that run natively on direct current (DC), such as solar photovoltaics, electric vehicles, stationary batteries, and DC motors that drive heat pumps and other major appliances.","hedge":{"p":0.98,"label":"asserted"},"own_p":0.06,"main_claim_p":0.02,"quantitative":false,"quantitative_p":0.05,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.0,"background":1.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":1,"p":0.99,"id":"s1","own":false,"role":"background","text":"Today, these natively-DC devices typically connect within buildings through alternating current (AC) distribution systems, entailing significant energy losses due to conversions between AC and DC.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.07,"main_claim_p":0.02,"quantitative":false,"quantitative_p":0.12,"role_probabilities":{"gap":0.01,"method":0.0,"result":0.0,"background":0.99,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":2,"p":0.92,"id":"s2","own":false,"role":"contribution","text":"This paper investigates the alternative of connecting DC devices through DC distribution.","hedge":{"p":0.69,"label":"asserted"},"own_p":0.35,"main_claim_p":0.07,"quantitative":false,"quantitative_p":0.05,"role_probabilities":{"gap":0.03,"method":0.0,"result":0.0,"background":0.05,"limitation":0.0,"future_work":0.0,"contribution":0.92,"interpretation":0.0}},{"i":3,"p":0.66,"id":"s3","own":true,"role":"result","text":"Specifically, this paper shows through laboratory and field experiments that an off-the-shelf residential heat pump designed for conventional AC systems can be powered directly on DC with few hardware modifications and little change in performance.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.96,"main_claim_p":0.76,"quantitative":false,"quantitative_p":0.24,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.66,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.34,"interpretation":0.0}},{"i":4,"p":1.0,"id":"s4","own":true,"role":"result","text":"Supporting simulations of a DC nanogrid including {historical heat pump and rest-of-house load measurements,} a solar photovoltaic array, and a stationary battery suggest that connecting these devices through DC distribution could decrease annual electricity bills by 12.5% with an after-market AC-to-DC heat pump retrofit and by 16.7% with a heat pump designed to run on DC.","hedge":{"p":0.96,"label":"hedged_possibility"},"own_p":0.87,"main_claim_p":0.41,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":5,"p":1.0,"id":"s5","own":true,"role":"result","text":"The associated savings in gross nanogrid energy are 8% and 9.2%, respectively.","hedge":{"p":0.99,"label":"asserted"},"own_p":0.86,"main_claim_p":0.12,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}}]},"compiled":{"main_claim":{"p":0.54,"text":"Specifically, this paper shows through laboratory and field experiments that an off-the-shelf residential heat pump designed for conventional AC systems can be powered directly on DC with few hardware modifications and little change in performance.","location":"abstract s3","hedge_strength":{"p":1.0,"label":"asserted"}},"provenance":{"route":{"via":"TypeSafe API","model":"classifier-1.13.0","endpoint":"https://api.typesafe.ai/v1/systemone","provider":"TypeSafe"},"packing":"one request per paper","requests":1,"input_tokens":5076,"cost_usd_reported":0.0},"compiled_at":"2026-09-23","bank_version":"abstract-p1-20260923","model_version":"classifier-1.13.0","abstract_states":{"claims_first":0.04,"states_limitation":0.19,"human_participants":0.08,"controlled_comparison":0.6,"randomized_assignment":0.01,"states_quantitative_result":0.99,"compares_with_prior_results":0.77,"mentions_code_or_data_availability":0.03},"evidential_basis":{"p":1.0,"value":"observation or experiment","probabilities":{"argument":0.0,"literature":0.0,"proof_or_derivation":0.0,"analysis_of_existing_data":0.0,"observation_or_experiment":1.0,"simulation_or_computation":0.0}},"contribution_type":{"p":1.0,"value":"empirical study","probabilities":{"review":0.0,"method_or_tool":0.0,"empirical_study":1.0,"simulation_study":0.0,"theoretical_result":0.0,"dataset_or_benchmark":0.0,"position_or_commentary":0.0}},"contribution_statement":{"p":1.0,"text":"Specifically, this paper shows through laboratory and field experiments that an off-the-shelf residential heat pump designed for conventional AC systems can be powered directly on DC with few hardware modifications and little change in performance.","location":"abstract s3"}},"coverage":{"tier":"abstract","levels_run":["P abstract"],"not_examined":["full text","figures and tables","references and citing sentences","relations to other papers"],"sources_read":["arXiv listing abstract v3"],"levels_not_run":["S sections","T body sentences","C citations","R cross-paper relations"],"sentences_examined":6,"sentences_in_abstract":6},"measured_accuracy":{"url":"https://pith.science/accuracy","measured_on":"2026-10-02","method":"two independent model families labelled a fresh random sample blind; the figure is how often the published label matches their consensus","sentence_role_agreement":0.92,"main_claim_agreement":0.908,"typed_citation_agreement":0.933,"typed_citation_agreement_95_interval":[0.917,0.945],"review_comments_accurate":0.758,"review_comments_accurate_95_interval":[0.684,0.82],"review_caught_admitted_error_found_or_related":0.448,"review_comments_judged":{"judged_by":["gpt-5.6-luna","grok-4.7"],"judged_against":"Pith's own text copy of each paper: text extracted from the PDF, the first 90,000 characters","measured_on":"2026-10-04","accurate":113,"decided":149,"sampled_reviews":200,"split_by_lane":false,"by_lane":"https://pith.science/accuracy#by-lane"}}}