{"paper":{"title":"Development and Experimental Characterization of a Compact $^{228}$Th--D$_2$O Photoneutron Source for Low-Energy Nuclear Recoil Calibration","arxiv_id":"2611.16415","primary_cat":"physics.ins-det","submitted_at":"2026-11-12T07:25:56+00:00","version_compiled":"v1"},"notice":"Every quoted sentence is the authors' text from the arXiv listing abstract. Labels and probabilities are the outputs of classifier-1.13.0 on the question bank abstract-p1-20260923, exactly as returned. No sentence in this record was written by a language model.","schema":"pith.compiled-record/v0","status":"compiled","abstract":{"source":"arXiv listing abstract v1","sentences":[{"i":0,"p":0.99,"id":"s0","own":false,"role":"background","text":"Calibrating the few-keV nuclear-recoil response of liquid xenon detectors calls for a low-energy neutron source.","hedge":{"p":0.99,"label":"asserted"},"own_p":0.05,"main_claim_p":0.03,"quantitative":true,"quantitative_p":0.57,"role_probabilities":{"gap":0.01,"method":0.0,"result":0.0,"background":0.99,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":1,"p":0.84,"id":"s1","own":true,"role":"contribution","text":"We have developed and characterized a $^{228}$Th--D$_2$O photoneutron source that converts the 2.615~MeV $\\gamma$ rays from $^{208}$Tl into sub-MeV neutrons through the D($\\gamma$,n)p reaction.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.96,"main_claim_p":0.08,"quantitative":true,"quantitative_p":0.94,"role_probabilities":{"gap":0.0,"method":0.16,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.84,"interpretation":0.0}},{"i":2,"p":0.95,"id":"s2","own":true,"role":"method","text":"After optimizing the D$_2$O geometry to balance neutron production against escape efficiency, we validated the chosen configuration experimentally.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.96,"main_claim_p":0.04,"quantitative":false,"quantitative_p":0.05,"role_probabilities":{"gap":0.0,"method":0.95,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.05,"interpretation":0.0}},{"i":3,"p":1.0,"id":"s3","own":true,"role":"result","text":"The forward emission rate is $1734 \\pm 76~(\\mathrm{stat.}) \\pm 65~(\\mathrm{sys.})~\\mathrm{h}^{-1}$, and the spectrum unfolded from Bonner sphere data is concentrated at $0.17$--$0.22~\\mathrm{MeV}$.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.96,"main_claim_p":0.06,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":4,"p":0.71,"id":"s4","own":true,"role":"result","text":"In a 220~h exposure of PandaX-20T, the same configuration should provide about 1000 selected nuclear-recoil events.","hedge":{"p":0.85,"label":"hedged_possibility"},"own_p":0.51,"main_claim_p":0.06,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.71,"background":0.0,"limitation":0.0,"future_work":0.02,"contribution":0.0,"interpretation":0.27}},{"i":5,"p":0.99,"id":"s5","own":true,"role":"interpretation","text":"These results support the use of a long-lived $^{228}$Th--D$_2$O source for low-energy neutron calibration of large liquid xenon detectors.","hedge":{"p":0.73,"label":"hedged_possibility"},"own_p":0.66,"main_claim_p":0.94,"quantitative":false,"quantitative_p":0.04,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.01,"contribution":0.0,"interpretation":0.99}}]},"compiled":{"main_claim":{"p":1.0,"text":"These results support the use of a long-lived $^{228}$Th--D$_2$O source for low-energy neutron calibration of large liquid xenon detectors.","location":"abstract s5","hedge_strength":{"p":0.73,"label":"hedged possibility"}},"provenance":{"route":{"via":"TypeSafe API","model":"classifier-1.13.0","endpoint":"https://api.typesafe.ai/v1/systemone","provider":"TypeSafe"},"packing":"one request per paper","requests":1,"input_tokens":5192,"cost_usd_reported":0.0},"compiled_at":"2026-11-13","bank_version":"abstract-p1-20260923","model_version":"classifier-1.13.0","abstract_states":{"claims_first":0.04,"states_limitation":0.16,"human_participants":0.02,"controlled_comparison":0.03,"randomized_assignment":0.01,"states_quantitative_result":0.99,"compares_with_prior_results":0.07,"mentions_code_or_data_availability":0.02},"evidential_basis":{"p":1.0,"value":"observation or experiment","probabilities":{"argument":0.0,"literature":0.0,"proof_or_derivation":0.0,"analysis_of_existing_data":0.0,"observation_or_experiment":1.0,"simulation_or_computation":0.0}},"contribution_type":{"p":0.89,"value":"method or tool","probabilities":{"review":0.0,"method_or_tool":0.89,"empirical_study":0.11,"simulation_study":0.0,"theoretical_result":0.0,"dataset_or_benchmark":0.0,"position_or_commentary":0.0}},"contribution_statement":{"p":1.0,"text":"We have developed and characterized a $^{228}$Th--D$_2$O photoneutron source that converts the 2.615~MeV $\\gamma$ rays from $^{208}$Tl into sub-MeV neutrons through the D($\\gamma$,n)p reaction.","location":"abstract s1"}},"coverage":{"tier":"abstract","levels_run":["P abstract"],"not_examined":["full text","figures and tables","references and citing sentences","relations to other papers"],"sources_read":["arXiv listing abstract v1"],"levels_not_run":["S sections","T body sentences","C citations","R cross-paper relations"],"sentences_examined":6,"sentences_in_abstract":6},"measured_accuracy":{"url":"https://pith.science/accuracy","measured_on":"2026-10-02","method":"two independent model families labelled a fresh random sample blind; the figure is how often the published label matches their consensus","sentence_role_agreement":0.92,"main_claim_agreement":0.908,"typed_citation_agreement":0.933,"typed_citation_agreement_95_interval":[0.917,0.945],"review_comments_accurate":0.758,"review_comments_accurate_95_interval":[0.684,0.82],"review_caught_admitted_error_found_or_related":0.448,"review_comments_judged":{"judged_by":["gpt-5.6-luna","grok-4.7"],"judged_against":"Pith's own text copy of each paper: text extracted from the PDF, the first 90,000 characters","measured_on":"2026-10-04","accurate":113,"decided":149,"sampled_reviews":200,"split_by_lane":false,"by_lane":"https://pith.science/accuracy#by-lane"}}}