{"paper":{"title":"A Feasibility Study of Whole-Cerebrum Task-Based fMRI at 0.55 T: Motor and Visual Tasks Using Single-Shot EPI","arxiv_id":"2611.17211","primary_cat":"physics.med-ph","submitted_at":"2026-11-12T18:09:22+00:00","version_compiled":"v1"},"notice":"Every quoted sentence is the authors' text from the arXiv listing abstract. Labels and probabilities are the outputs of classifier-1.13.0 on the question bank abstract-p1-20260923, exactly as returned. No sentence in this record was written by a language model.","schema":"pith.compiled-record/v0","status":"compiled","abstract":{"source":"arXiv listing abstract v1","sentences":[{"i":0,"p":0.85,"id":"s0","own":false,"role":"contribution","text":"Purpose: To evaluate the feasibility of whole-cerebrum task-based fMRI on a modern 0.55T system, examining the effects of extended scan duration and within-session consistency on functional mapping outcomes and comparison to acquisition with matched tasks at 3.0T.","hedge":{"p":0.66,"label":"unclear"},"own_p":0.44,"main_claim_p":0.03,"quantitative":true,"quantitative_p":0.87,"role_probabilities":{"gap":0.01,"method":0.01,"result":0.0,"background":0.13,"limitation":0.0,"future_work":0.0,"contribution":0.85,"interpretation":0.0}},{"i":1,"p":1.0,"id":"s1","own":true,"role":"method","text":"Methods: Six healthy participants were scanned at 0.55T using a single-shot EPI sequence during bilateral finger-tapping and visual checkerboard tasks.","hedge":{"p":0.96,"label":"asserted"},"own_p":0.96,"main_claim_p":0.01,"quantitative":true,"quantitative_p":0.94,"role_probabilities":{"gap":0.0,"method":1.0,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":2,"p":1.0,"id":"s2","own":true,"role":"method","text":"Data were processed using an open-source pipeline.","hedge":{"p":0.99,"label":"asserted"},"own_p":0.8,"main_claim_p":0.01,"quantitative":false,"quantitative_p":0.03,"role_probabilities":{"gap":0.0,"method":1.0,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":3,"p":0.99,"id":"s3","own":true,"role":"method","text":"To investigate sensitivity improvements, two consecutive 5-minute runs were concatenated.","hedge":{"p":0.78,"label":"asserted"},"own_p":0.94,"main_claim_p":0.02,"quantitative":true,"quantitative_p":0.9,"role_probabilities":{"gap":0.0,"method":0.99,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.01,"interpretation":0.0}},{"i":4,"p":0.99,"id":"s4","own":true,"role":"method","text":"Within-session consistency was also assessed.","hedge":{"p":0.81,"label":"asserted"},"own_p":0.89,"main_claim_p":0.01,"quantitative":false,"quantitative_p":0.03,"role_probabilities":{"gap":0.0,"method":0.99,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.01,"interpretation":0.0}},{"i":5,"p":0.98,"id":"s5","own":true,"role":"method","text":"A representative 3T dataset provided additional reference context for temporal dynamics and statistical sensitivity.","hedge":{"p":0.94,"label":"asserted"},"own_p":0.51,"main_claim_p":0.01,"quantitative":false,"quantitative_p":0.27,"role_probabilities":{"gap":0.0,"method":0.98,"result":0.0,"background":0.01,"limitation":0.0,"future_work":0.0,"contribution":0.01,"interpretation":0.0}},{"i":6,"p":1.0,"id":"s6","own":true,"role":"result","text":"Results: Task-evoked activations were detected at 0.55T using Family-Wise Error (FWE) rate correction (p < 0.05) in both motor and visual cortices.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.96,"main_claim_p":0.04,"quantitative":true,"quantitative_p":0.92,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":7,"p":1.0,"id":"s7","own":true,"role":"result","text":"While single 5-minute runs provided baseline detectability, extending the acquisition to 10 minutes increased t-statistic magnitudes and cluster extents while substantially reducing background noise (47% reduction in voxelwise dispersion).","hedge":{"p":1.0,"label":"asserted"},"own_p":0.96,"main_claim_p":0.06,"quantitative":true,"quantitative_p":0.99,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":8,"p":1.0,"id":"s8","own":true,"role":"result","text":"Run-to-run comparisons showed consistent peak locations and statistical significance across participants.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.95,"main_claim_p":0.02,"quantitative":true,"quantitative_p":0.54,"role_probabilities":{"gap":0.0,"method":0.0,"result":1.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.0}},{"i":9,"p":0.97,"id":"s9","own":true,"role":"result","text":"Comparison with the 3T reference demonstrated that statistical significance increases with acquisition time so that a 0.55T scan approximately matches 3T significance levels at twice the scan duration across the range compared.","hedge":{"p":0.99,"label":"asserted"},"own_p":0.9,"main_claim_p":0.13,"quantitative":true,"quantitative_p":0.98,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.97,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":0.03}},{"i":10,"p":0.75,"id":"s10","own":true,"role":"interpretation","text":"Conclusion: Whole-cerebrum task fMRI is feasible at 0.55T using standard EPI and modern high-performance gradients.","hedge":{"p":1.0,"label":"asserted"},"own_p":0.82,"main_claim_p":0.95,"quantitative":false,"quantitative_p":0.23,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.22,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.03,"interpretation":0.75}},{"i":11,"p":1.0,"id":"s11","own":true,"role":"interpretation","text":"These results indicate that modest extensions in scan duration can compensate for reduced intrinsic BOLD sensitivity at lower field strengths.","hedge":{"p":0.99,"label":"hedged_possibility"},"own_p":0.83,"main_claim_p":0.18,"quantitative":false,"quantitative_p":0.12,"role_probabilities":{"gap":0.0,"method":0.0,"result":0.0,"background":0.0,"limitation":0.0,"future_work":0.0,"contribution":0.0,"interpretation":1.0}}]},"compiled":{"main_claim":{"p":0.99,"text":"Conclusion: Whole-cerebrum task fMRI is feasible at 0.55T using standard EPI and modern high-performance gradients.","location":"abstract s10","hedge_strength":{"p":1.0,"label":"asserted"}},"provenance":{"route":{"via":"TypeSafe API","model":"classifier-1.13.0","endpoint":"https://api.typesafe.ai/v1/systemone","provider":"TypeSafe"},"packing":"one request per paper","requests":1,"input_tokens":8875,"cost_usd_reported":0.0},"compiled_at":"2026-11-14","bank_version":"abstract-p1-20260923","model_version":"classifier-1.13.0","abstract_states":{"claims_first":0.03,"states_limitation":0.33,"human_participants":0.99,"controlled_comparison":0.6,"randomized_assignment":0.02,"states_quantitative_result":0.99,"compares_with_prior_results":0.96,"mentions_code_or_data_availability":0.15},"evidential_basis":{"p":1.0,"value":"observation or experiment","probabilities":{"argument":0.0,"literature":0.0,"proof_or_derivation":0.0,"analysis_of_existing_data":0.0,"observation_or_experiment":1.0,"simulation_or_computation":0.0}},"contribution_type":{"p":1.0,"value":"empirical study","probabilities":{"review":0.0,"method_or_tool":0.0,"empirical_study":1.0,"simulation_study":0.0,"theoretical_result":0.0,"dataset_or_benchmark":0.0,"position_or_commentary":0.0}},"contribution_statement":{"p":0.53,"text":"Purpose: To evaluate the feasibility of whole-cerebrum task-based fMRI on a modern 0.55T system, examining the effects of extended scan duration and within-session consistency on functional mapping outcomes and comparison to acquisition with matched tasks at 3.0T.","location":"abstract s0"}},"coverage":{"tier":"abstract","levels_run":["P abstract"],"not_examined":["full text","figures and tables","references and citing sentences","relations to other papers"],"sources_read":["arXiv listing abstract v1"],"levels_not_run":["S sections","T body sentences","C citations","R cross-paper relations"],"sentences_examined":12,"sentences_in_abstract":12},"measured_accuracy":{"url":"https://pith.science/accuracy","measured_on":"2026-10-02","method":"two independent model families labelled a fresh random sample blind; the figure is how often the published label matches their consensus","sentence_role_agreement":0.92,"main_claim_agreement":0.908,"typed_citation_agreement":0.933,"typed_citation_agreement_95_interval":[0.917,0.945],"review_comments_accurate":0.758,"review_comments_accurate_95_interval":[0.684,0.82],"review_caught_admitted_error_found_or_related":0.448,"review_comments_judged":{"judged_by":["gpt-5.6-luna","grok-4.7"],"judged_against":"Pith's own text copy of each paper: text extracted from the PDF, the first 90,000 characters","measured_on":"2026-10-04","accurate":113,"decided":149,"sampled_reviews":200,"split_by_lane":false,"by_lane":"https://pith.science/accuracy#by-lane"}}}