{"id":"8a6c8835-29ff-4e06-a4df-606578def51b","arxiv_id":"2611.10601","paper_version":1,"verdict":"ACCEPT","confidence":"HIGH","novelty_score":6.0,"correctness_risk":"medium","formal_verification":"none","parameter_count":0,"one_line_summary":"LLM-generated content in medical records modestly degrades downstream clinical summarization and causes diagnostic overcalls to propagate unnoticed.","lead":"This paper finds that when AI-generated summaries are inserted into a patient's medical record, downstream AI models produce worse clinical summaries and may propagate unconfirmed diagnoses. It matters because as AI-written content accumulates in electronic health records, these effects could silently degrade patient care and evade standard quality checks.","discovery_kind":"new_application","skeptic_critique":{"model":"deepseek/deepseek-v4-flash","headline":"No significant objection identified.","rationale":"The reader's weakest_assumption correctly identifies the synthetic overcall construction as the most fragile part of the argument. However, the authors' own clinician review provides evidence that the effect survives even when restricting to genuine overcalls, and the paper is explicit about its limitations. The bloat experiments are clean and well-controlled. I find no unaddressed concern that would justify adjusting the ACCEPT verdict. The paper makes a solid, honest contribution.","tokens_in":18762,"tokens_out":3115,"duration_ms":27955,"concrete_test":"Reproduce the overcall propagation analysis on the subset of 14 clinician-confirmed genuine overcalls (Appendix F), reporting the propagation rate and 95% CI for this subgroup alone. If the rate remains significantly above zero and comparable to the full-sample estimate, the concern about synthetic construction is fully addressed.","verdict_should_be":"UNCHANGED","load_bearing_attack":"The paper's central claim—that LLM-generated content in medical records can affect downstream LLMs—is supported by two independent lines of evidence (note bloat and diagnostic overcall). The strongest potential concern is the ecological validity of the synthetic diagnostic overcall construction (ICD-9-based injects, many judged not genuine by clinician review, §B.2, Appendix F). However, the authors transparently acknowledge this limitation (§5, §B.2, Appendix F) and partially mitigate it with a blinded clinician review that confirms the propagation pattern holds even for the subset of genuine overcalls (7/14 propagated, 5/7 with potential clinical impact). The bloat experiments are robust across doses, reader models, and generators, with a rephrased control isolating content from authorship. No critical flaw or internal inconsistency was identified that would weaken the core findings beyond what the authors themselves report.","agreement_with_reader":"agree"},"referee_report":{"model":"deepseek/deepseek-v4-flash","summary":"This paper investigates whether LLM-generated content in medical records affects downstream LLMs that later process those records. It studies two artifacts: note bloat (inserting AI-written summaries of preceding notes) and diagnostic overcall (injecting an unconfirmed differential diagnosis). Using the MIMIC-III dataset across 300 admissions, seven reader models, two generators, and clinician review, the authors report that AI-written summary notes at insertion doses from 0.05 to 0.50 cause modest but consistent degradation in downstream summarization (ROUGE-L, judged accuracy, supported-claim share) relative to human-written text of equal length. Injected diagnostic overcalls propagate into downstream outputs at rates up to 24.6% (related targets) without detectable changes in standard quality metrics. A rephrased control isolates content from authorship, confirming the effect is due to content, not wording. The paper concludes that AI-generated content in medical records can affect downstream LLMs, even when generated harmlessly.","tokens_in":19041,"tokens_out":2106,"duration_ms":20798,"significance":"If the results hold, this work has immediate practical implications for the deployment of LLM-based clinical documentation tools, which are already in use at scale. The finding that AI-generated summary notes degrade downstream summarization, even modestly, and that unsupported differentials can propagate without detection by standard quality metrics, raises patient-safety concerns. The experimental design is strong: paired admissions, multiple doses, authorship controls (rephrasing), seven reader models from four families, two generators, and human validation of the overcall evaluator. The rephrased control convincingly separates content from authorship. The paper ships all prompts for reproducibility. The main limitations are the synthetic nature of the AI content (MIMIC-III predates AI documentation) and the ICD-code-based overcall construction, which the authors transparently acknowledge and partially mitigate with clinician review.","major_comments":[{"comment":"The clinician review (Appendix F) found that only 14 of 24 injections (58%) were genuine overcalls; the remaining 10 were reasonable given the record. The overall propagation rates reported in Table 1 (e.g., 24.6% for related targets) average over all injections, including non-genuine ones. While the authors note that genuine overcalls still propagated (7/14), the sample is small and the propagation rate for non-genuine injections is not separately reported. Since the central claim concerns the propagation of genuine AI-generated overcalls, the paper should report or estimate the propagation rate restricted to the subset of injections judged to be genuine overcalls, or discuss how the inclusion of non-genuine overcalls might affect the external validity of the measured rates. The authors already acknowledge the limitation (sentence b110, b192), but the reported primary estimates in Table 1 conflate two categories of injections.","section":"Table 1 & Appendix F","authors_acknowledge":"This may explain why the clinician review (Appendix F) judged 10 of 24 injections not to be genuine overcalls.","authors_acknowledge_p":0.69},{"comment":"The bloat effect, while consistent, is modest—'about half the run-to-run variation of a single summary' (sentence b85 context). The clinical significance of a 0.47-point drop in judge-rated accuracy (1–5 scale) and a 3–4 pp drop in supported-claim share at dose 0.5 is not fully discussed. The paper would benefit from a brief qualitative assessment: at what dose does the degradation become clinically noticeable? Do the supported-claim losses systematically affect any particular type of claim (e.g., medications vs. findings)? The conclusion asserts that these effects 'should draw greater attention to the reliability of AI-based documentation tools,' but the modest effect sizes should be weighed against the practical costs of note bloat in real EHRs. This is a framing issue, not a flaw, but addressing it would strengthen the paper.","section":"§4.1 & Figure 2","authors_acknowledge":null,"authors_acknowledge_p":null}],"minor_comments":[{"comment":"The abstract mentions 'seven reader models from four families' but does not name them; consider adding a brief parenthetical list for clarity.","section":"Abstract & §1","authors_acknowledge":null,"authors_acknowledge_p":null},{"comment":"The notation 'x_a,d_i' is introduced but the subscript ordering (a for setting, d for dose, i for admission) is not explicitly stated until later; define the subscripts at first use.","section":"§3.2","authors_acknowledge":null,"authors_acknowledge_p":null},{"comment":"The caption says 'Shades are 95% bootstrap CIs.' The figure uses semi-transparent bands; this is clear, but consider adding a note that the CIs are percentile bootstrap intervals from 2,000 resamples (as stated in §3.3).","section":"Figure 2 caption","authors_acknowledge":null,"authors_acknowledge_p":null},{"comment":"The Bonferroni adjustment is applied over the three main-reader rows. Clarify in the table title whether the intervals are adjusted for the three rows or for all comparisons in the table. Also, the row 'Five other readers 5.8–31.2 2.5–23.9' shows ranges; consider adding a footnote explaining these are the minima and maxima of the reader-specific rates (from Appendix Table 3).","section":"Table 1","authors_acknowledge":null,"authors_acknowledge_p":null},{"comment":"The rephrased control (R-red) is applied only at doses 0.10, 0.25, and 0.50 (stated in §3.2 and Appendix B.1). In Table 5, the same three doses are reported. The main bloat results in Figure 2 include doses 0.05, 0.15, 0.20, 0.33 as well; the rephrased control is not tested at these doses. A brief justification for the restricted dose set would be helpful, even if it is due to computational cost.","section":"Appendix B.1","authors_acknowledge":null,"authors_acknowledge_p":null},{"comment":"The sentence states 'AI-red still lowered ROUGE-L by 0.28, 0.59 and 0.92 pp against R-red (Appendix Table 5).' This is correct, but the phrasing 'still lowered' might imply a competition between effects; consider rephrasing to clearly separate the two contrasts (R-red vs. H-red isolates wording; AI-red vs. R-red isolates content). The text already does this, but a small rewording could avoid potential confusion.","section":"§4.1, sentence b87","authors_acknowledge":null,"authors_acknowledge_p":null},{"comment":"The 'Diagnostic-overcall edit' prompt instructs the model to 'change nothing else' and 'output the rewritten passage only.' This is appropriate, but the prompt does not explicitly constrain the model to keep the same passage length or structure; in practice, Nemotron-generated edits were much shorter (median 5–6 added words vs. Qwen's 16). This length difference is noted in Appendix E.1 and is not a flaw, but the prompt design may partially explain it. Consider adding a brief note in Appendix B.2.","section":"Appendix G.2","authors_acknowledge":null,"authors_acknowledge_p":null},{"comment":"There are a few missing spaces or punctuation inconsistencies (e.g., 'Bloat' and 'Distortion' in the abstract are bolded with colons but not consistently; 'BHC generation' in Figure 1 has a line break). A thorough copy-edit would improve readability.","section":"General","authors_acknowledge":null,"authors_acknowledge_p":null}],"recommendation":"minor_revision"},"author_rebuttal":null,"desk_editor":{"model":"deepseek/deepseek-v4-flash","letter":"This paper does something straightforward that nobody has done before: it takes a real EHR corpus, injects AI-written notes or diagnostic overcalls in controlled amounts, and measures what happens when a second LLM reads the altered record. The answer is that small but reliable degradations occur, and that overcalls—hedged, unconfirmed differentials—get carried forward into summaries at rates up to 24% without tripping standard metrics. The study design is the strong point: paired admissions, multiple doses, a rephrasing control that isolates content from authorship, seven reader models, two generators, and a blinded clinician review. The rephrased control cleanly shows that the bloat effect comes from what the AI summary says, not from its wording being AI-like. The clinician validation on a subset of overcall pairs is rare in this area and adds credibility. The authors are transparent about their limitations—synthetic data, ICD-9-based targets that 10 of 24 times were not genuine overcalls, modest cohort size. The overcall construction is the softest spot: many injections read verbatim from a condition list, which a clinician would not write. But the propagation pattern held even for the genuine overcalls (7 of 14 propagated, 5 of those with potential clinical impact), so the central finding survives its own stress test. The effect sizes are modest—a few tenths of a ROUGE-L point, a fraction of a point on a 1–5 accuracy scale—but consistent across models. That consistency is the story, not the size. This is a conference-paper-level contribution. It is clearly scoped, methodologically careful, and appropriately cautious in its conclusions. For a reader in NLP for healthcare or AI safety evaluation, this is worth a serious refereeing. I would say yes to peer review and expect a solid publication after minor tightening of the overcall narrative.","headline":"Solid, honest study showing that AI-generated clinical notes can silently degrade downstream LLM summaries and propagate unconfirmed diagnoses, with effect sizes that are modest but consistent.","tokens_in":19462,"tokens_out":880,"duration_ms":10148},"pith_extraction":{"msc":[],"pacs":[],"model":"deepseek/deepseek-v4-flash","headline":"LLMs reading medical records are subtly influenced by prior AI-generated notes, even when those notes are neutral.","keywords":["large language models","clinical documentation","note bloat","diagnostic overcall","summarization","downstream effects","LLM evaluation"],"falsifier":"A prospective study where clinicians write diagnostic overcalls for the same MIMIC-III records, without using ICD-9 code rules, and then measure downstream LLM propagation rates; if propagation rates differ significantly from the paper's estimates, it would suggest the ICD-based filtering method biases the results.","tokens_in":20284,"feed_emoji":"📝","tokens_out":5984,"duration_ms":55739,"temperature":0.7,"pith_summary":"This paper shows that when medical records contain AI-generated notes, downstream LLMs that later read those records produce different summaries than they would from human-written notes of the same length and content. The authors study two types of AI-induced artifacts: 'note bloat' (accumulating AI-generated summary notes) and 'diagnostic overcall' (inserting hedged, unconfirmed differential diagnoses). In controlled experiments on 300 MIMIC-III admissions, they find that AI-written summary notes consistently degrade downstream hospital-course summarization compared to matched human-written or boilerplate notes. Injected diagnostic overcalls propagate into downstream summaries at rates between 2.5% and 31.2% depending on the reader model, without being detected by standard quality metrics like ROUGE-L or BERTScore. The paper argues that the bidirectional nature of LLMs both reading and writing to the record creates a feedback loop that requires monitoring.","feed_headline":"AI notes in medical records quietly alter later AI readers","feed_subtitle":"Diagnostic overcalls propagate up to 24.6% of the time while standard metrics miss the error.","key_machinery":"The controlled paired-perturbation experimental design is the central machinery. For bloat, the same record is augmented with AI-written summary notes (AI-red) or with human-written text of matched length and position (H-red and F-red), and the downstream summary from each version is compared to the original-record summary. For distortion, a selected passage is neutrally rephrased (control) or additionally edited to include a hedged differential diagnosis (overcall), and the two downstream summaries are compared. The key comparison is within-admission, paired, isolating the artifact's effect. The LLM-as-judge evaluator and clinician review provide validation for overcall propagation.","core_discovery":"The paper establishes that LLM-generated content in medical records systematically alters what downstream LLMs produce from those records, even when the AI content is neutral in tone. For note bloat, the effect is modest—reducing ROUGE-L by about 0.7 to 1.1 percentage points at moderate doses—but it is consistent across seven reader models and appears to be driven by the content of the AI notes, not just their wording or length. For diagnostic overcall, the propagation is substantial: unconfirmed differentials reappear in summaries up to 24.6% of the time for related targets, and clinician review confirms that 7 of 14 genuine overcalls propagated, 5 of which were rated likely to prompt unnecessary clinical work-up. Critically, the overcall propagation is invisible to standard document-level metrics, meaning current evaluation practices would miss this failure mode.","pith_inferences":["The study likely underestimates real-world risk because genuine clinician-written overcalls may be more subtle and harder for LLMs to resist, whereas the synthetic overcalls were often judged as plausible rather than genuine (10 of 24 not genuine).","The fact that propagation rates varied by model and by generator (Nemotron-written edits propagated less) suggests that the exact wording and context of the overcall matter; future work could systematically vary overcall phrasing to understand boundaries.","The finding that even neutral AI summaries ('bloat') degrade performance implies that any AI-generated text in the record—even apparently helpful summaries—may shift downstream outputs, raising safety concerns for ambient scribe tools that automatically insert AI notes.","The absence of detectable changes in standard metrics implies that current automated evaluation of clinical summarization may miss systematic errors; developing targeted factuality metrics for the clinical domain is a concrete next step."],"forward_implications":["AI-assisted documentation tools should include monitoring for downstream effects on subsequent AI readers, not just on the immediate note quality.","Standard summarization metrics (ROUGE-L, BERTScore) are insufficient to detect targeted errors like propagated diagnostic overcalls; factuality or claim-level metrics may be needed.","The bloat effect, while modest, could compound over multiple admissions as AI notes accumulate, potentially causing larger shifts in patient summaries.","The variation in propagation rates across reader models suggests that model selection matters for safety-critical clinical summarization.","The paper calls for simulating recursive AI-in-the-loop documentation to understand long-term effects."],"supporting_citations":[{"why":"provides the MIMIC-III critical care database used for all cohort and experiment construction.","marker":"Johnson et al., 2016"},{"why":"demonstrates expert-level medical QA performance, establishing the capability baseline for LLMs in healthcare.","marker":"Singhal et al., 2025"},{"why":"documents real-world deployment of ambient AI scribes, motivating the clinical documentation loop scenario.","marker":"Ma et al., 2025"},{"why":"shows that note bloat degrades supervised NLP models, directly motivating the bloat artifact study.","marker":"Liu et al., 2022"},{"why":"shows that models degrade when trained on recursively generated data, a training-time analogue to the inference-time recursive context studied here.","marker":"Shumailov et al., 2024"},{"why":"finds that LLMs degrade in interactive medical QA compared to single-turn, supporting the hypothesis that LLMs are sensitive to context quality.","marker":"Li et al., 2024"},{"why":"demonstrates the 'lost in the middle' effect where LLMs use context unevenly, motivating the study of how inserted notes affect reading.","marker":"Liu et al., 2024"}],"fun_headline_variants":["AI notes seed unnoticed errors in later AI readers","Diagnostic overcalls from AI spread 24.6% unseen","LLM clinical bloat and overcall echo through AI pipeline","Unconfirmed diagnoses in AI notes propagate to summaries","AI-written records quietly distort later AI output"],"cache_read_input_tokens":0,"weakest_assumption_plain":"The diagnostic overcall experiment assumes that an injected differential diagnosis selected by ICD-9 code co-occurrence is a plausible simulation of a real AI-generated clinical overcall, but clinician review found that only 14 of 24 such injections were judged as genuine overcalls, meaning the measured propagation rates may not generalize to how LLMs handle real-world clinician-written overcalls.","fun_headline_variants_meta":{"raw":{"variants":["AI notes seed unnoticed errors in later AI readers","Diagnostic overcalls from AI spread 24.6% unseen","LLM clinical bloat and overcall echo through AI pipeline","Unconfirmed diagnoses in AI notes propagate to summaries","AI-written records quietly distort later AI output"]},"model":"deepseek/deepseek-v4-flash","effort":"low","cost_usd":5.7e-05,"raw_usage":{"cost":5.681942e-05,"is_byok":false,"cost_details":{"upstream_inference_cost":5.681942e-05,"upstream_inference_prompt_cost":3.557106e-05,"upstream_inference_completions_cost":2.124836e-05},"total_tokens":1274,"prompt_tokens":981,"completion_tokens":293,"prompt_tokens_details":{"audio_tokens":0,"video_tokens":0,"cached_tokens":0,"cache_write_tokens":0},"completion_tokens_details":{"audio_tokens":0,"image_tokens":0,"reasoning_tokens":215}},"tokens_in":981,"tokens_out":293,"cost_source":"openrouter_usage","duration_ms":3548,"image_pages":[],"temperature":1.0,"billed_attempts":1,"reasoning_tokens":215,"transport_provider":"openrouter","cache_read_input_tokens":0,"cache_creation_input_tokens":0},"cache_creation_input_tokens":0},"created_at":"2026-11-10T22:00:12.629908+00:00","model_set":{"reader":"deepseek/deepseek-v4-flash"},"pipeline_version":"pith-pipeline@v1.4.1-daily-deepseek-or-medium","input_kind":null,"input_chars":null,"input_total_chars":null,"passes_missing":null,"published_standing":null,"published_confidence":null,"objection_audit":null,"run_record":null,"basis":{"kind":"not_recorded","source":null,"chars_given":null,"chars_total":null},"receipt":null,"falsifier":"A prospective study where clinicians write diagnostic overcalls for the same MIMIC-III records, without using ICD-9 code rules, and then measure downstream LLM propagation rates; if propagation rates differ significantly from the paper's estimates, it would suggest the ICD-based filtering method biases the results.","supporting_citations":[{"cited_title":"MIMIC-III, a freely accessible critical care database","cited_arxiv_id":null,"evidence_quote":"provides the MIMIC-III critical care database used for all cohort and experiment construction."},{"cited_title":"Toward expert-level medical question answering with large language models","cited_arxiv_id":null,"evidence_quote":"demonstrates expert-level medical QA performance, establishing the capability baseline for LLMs in healthcare."},{"cited_title":"“Note Bloat” impacts deep learning-based NLP models for clinical prediction tasks","cited_arxiv_id":null,"evidence_quote":"shows that note bloat degrades supervised NLP models, directly motivating the bloat artifact study."},{"cited_title":"AI models collapse when trained on recursively generated data","cited_arxiv_id":null,"evidence_quote":"shows that models degrade when trained on recursively generated data, a training-time analogue to the inference-time recursive context studied here."},{"cited_title":"Lost in the middle: How language models use long contexts","cited_arxiv_id":null,"evidence_quote":"demonstrates the 'lost in the middle' effect where LLMs use context unevenly, motivating the study of how inserted notes affect reading."}],"lane_accuracy":{"status":"not yet measured","lane":{"model":"deepseek/deepseek-v4-flash","input_kind":null},"url":"https://pith.science/accuracy"},"review_version":1}