{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2025:2SW4G4VG43UQ5JCHYRLCVD6UT6","short_pith_number":"pith:2SW4G4VG","schema_version":"1.0","canonical_sha256":"d4adc372a6e6e90ea447c4562a8fd49f82caf501ef24eb7c2f7f9024d2ceb51d","source":{"kind":"arxiv","id":"2504.06981","version":2},"attestation_state":"computed","paper":{"title":"LCL Resonance Analysis and Damping in Single-Loop Grid-Forming Wind Turbines","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","headline":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances.","cross_cats":["cs.SY"],"primary_cat":"eess.SY","authors_text":"Frede Blaabjerg, Ioannis Lestas, Lin Cheng, Meng Chen, Yufei Xi","submitted_at":"2025-04-09T15:37:02Z","abstract_excerpt":"A common assumption in both grid-following (GFL) and grid-forming (GFM) control systems is that they are open-loop (OL) stable in the vicinity of high-frequency resonances. Hence classical loop-shaping approaches are often used for establishing stability margins and designing active damping (AD) strategies. This paper shows that single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and rob"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":true,"formal_links_present":false},"canonical_record":{"source":{"id":"2504.06981","kind":"arxiv","version":2},"metadata":{"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"eess.SY","submitted_at":"2025-04-09T15:37:02Z","cross_cats_sorted":["cs.SY"],"title_canon_sha256":"3af0f7216862fb67e892f5c068b1c7273aa96e0d8d41c37cedbce8de7c2708b1","abstract_canon_sha256":"3f45111251bcd922d4a89564a42c0cc55f9769106cc7c3c4acc9ec78222bfd88"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-06-03T01:05:43.827924Z","signature_b64":"ejIRwMSk7lMN7uo4jTcPYYTE0eLOaKX+j5bzk1bOPRiVIpP0JwnTqJJM4BCBkrOYr15a8iR6tMhiz64lyxidDw==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"d4adc372a6e6e90ea447c4562a8fd49f82caf501ef24eb7c2f7f9024d2ceb51d","last_reissued_at":"2026-06-03T01:05:43.827426Z","signature_status":"signed_v1","first_computed_at":"2026-06-03T01:05:43.827426Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"LCL Resonance Analysis and Damping in Single-Loop Grid-Forming Wind Turbines","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","headline":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances.","cross_cats":["cs.SY"],"primary_cat":"eess.SY","authors_text":"Frede Blaabjerg, Ioannis Lestas, Lin Cheng, Meng Chen, Yufei Xi","submitted_at":"2025-04-09T15:37:02Z","abstract_excerpt":"A common assumption in both grid-following (GFL) and grid-forming (GFM) control systems is that they are open-loop (OL) stable in the vicinity of high-frequency resonances. Hence classical loop-shaping approaches are often used for establishing stability margins and designing active damping (AD) strategies. This paper shows that single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and rob"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and robustness at high frequencies.","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"The analysis assumes a specific small-signal model of the SL-GFM with droop-I control and LCL filter, where the open-loop poles are determined by the control structure and parameters; if the model does not accurately represent the real system dynamics or if the droop-I implementation differs, the identified instability may not hold.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"Single-loop GFM wind turbine controls with droop-I RAP can exhibit open-loop instability near LCL resonances, leading to reduced high-frequency stability margins and requiring new active damping designs.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"073615db965733a56dea0413c7f3e194d8157f629f34235d23b97ad96a0f3cd8"},"source":{"id":"2504.06981","kind":"arxiv","version":2},"verdict":{"id":"22b0cc14-1e1f-4616-ac0b-57879a087457","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-22T20:24:05.222479Z","strongest_claim":"single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and robustness at high frequencies.","one_line_summary":"Single-loop GFM wind turbine controls with droop-I RAP can exhibit open-loop instability near LCL resonances, leading to reduced high-frequency stability margins and requiring new active damping designs.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"The analysis assumes a specific small-signal model of the SL-GFM with droop-I control and LCL filter, where the open-loop poles are determined by the control structure and parameters; if the model does not accurately represent the real system dynamics or if the droop-I implementation differs, the identified instability may not hold.","pith_extraction_headline":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances."},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/2504.06981/integrity.json","findings":[],"available":true,"detectors_run":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938"},"references":{"count":30,"sample":[{"doi":"","year":2024,"title":"M. Chen, D. Zhou, A. Tayyebi, E. Prieto-Araujo, F. D ¨orfler, and F. Blaabjerg, “On power control of grid-forming converters: Modeling, 10 0.9999 1 1.0001 1.0002 0.47 0.5 0.53 0 3 6 9 12 15 18 21 24 2","work_id":"536e2666-8b91-46b4-b9ba-ff104930b788","ref_index":1,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2024,"title":"Simultaneous assessment of multiple aspects of stability of power systems with renewable generation,","work_id":"441fe37a-b46d-4e61-b300-4dac36f33583","ref_index":2,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2024,"title":"Power electronics in wind generation systems,","work_id":"08b512d0-76c0-4aee-9516-4fcc28cac862","ref_index":3,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2020,"title":"Transient stability of voltage- source converters with grid-forming control: A design-oriented study,","work_id":"4037d816-8654-4ff0-a295-cef48236bea4","ref_index":4,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2035,"title":"Modeling of grid-forming and grid-following inverters for dynamic simulation of large-scale distribution systems,","work_id":"7a25ab58-0e8d-4740-9e92-74a1f178cd09","ref_index":5,"cited_arxiv_id":"","is_internal_anchor":false}],"resolved_work":30,"snapshot_sha256":"9cd35ce0a1cd32e0396db656967eb940c81ee8fd0e460ec0f03d498b405f1b90","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"2504.06981","created_at":"2026-06-03T01:05:43.827488+00:00"},{"alias_kind":"arxiv_version","alias_value":"2504.06981v2","created_at":"2026-06-03T01:05:43.827488+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2504.06981","created_at":"2026-06-03T01:05:43.827488+00:00"},{"alias_kind":"pith_short_12","alias_value":"2SW4G4VG43UQ","created_at":"2026-06-03T01:05:43.827488+00:00"},{"alias_kind":"pith_short_16","alias_value":"2SW4G4VG43UQ5JCH","created_at":"2026-06-03T01:05:43.827488+00:00"},{"alias_kind":"pith_short_8","alias_value":"2SW4G4VG","created_at":"2026-06-03T01:05:43.827488+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":0,"internal_anchor_count":0,"sample":[]},"formal_canon":{"evidence_count":0,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6","json":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6.json","graph_json":"https://pith.science/api/pith-number/2SW4G4VG43UQ5JCHYRLCVD6UT6/graph.json","events_json":"https://pith.science/api/pith-number/2SW4G4VG43UQ5JCHYRLCVD6UT6/events.json","paper":"https://pith.science/paper/2SW4G4VG"},"agent_actions":{"view_html":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6","download_json":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6.json","view_paper":"https://pith.science/paper/2SW4G4VG","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=2504.06981&json=true","fetch_graph":"https://pith.science/api/pith-number/2SW4G4VG43UQ5JCHYRLCVD6UT6/graph.json","fetch_events":"https://pith.science/api/pith-number/2SW4G4VG43UQ5JCHYRLCVD6UT6/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/action/timestamp_anchor","attest_storage":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/action/storage_attestation","attest_author":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/action/author_attestation","sign_citation":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/action/citation_signature","submit_replication":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/action/replication_record"}},"created_at":"2026-06-03T01:05:43.827488+00:00","updated_at":"2026-06-03T01:05:43.827488+00:00"}