{"bundle_type":"pith_open_graph_bundle","bundle_version":"1.0","pith_number":"pith:2025:2SW4G4VG43UQ5JCHYRLCVD6UT6","short_pith_number":"pith:2SW4G4VG","canonical_record":{"source":{"id":"2504.06981","kind":"arxiv","version":2},"metadata":{"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"eess.SY","submitted_at":"2025-04-09T15:37:02Z","cross_cats_sorted":["cs.SY"],"title_canon_sha256":"3af0f7216862fb67e892f5c068b1c7273aa96e0d8d41c37cedbce8de7c2708b1","abstract_canon_sha256":"3f45111251bcd922d4a89564a42c0cc55f9769106cc7c3c4acc9ec78222bfd88"},"schema_version":"1.0"},"canonical_sha256":"d4adc372a6e6e90ea447c4562a8fd49f82caf501ef24eb7c2f7f9024d2ceb51d","source":{"kind":"arxiv","id":"2504.06981","version":2},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2504.06981","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"arxiv_version","alias_value":"2504.06981v2","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2504.06981","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"pith_short_12","alias_value":"2SW4G4VG43UQ","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"pith_short_16","alias_value":"2SW4G4VG43UQ5JCH","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"pith_short_8","alias_value":"2SW4G4VG","created_at":"2026-06-03T01:05:43Z"}],"events":[{"event_type":"record_created","subject_pith_number":"pith:2025:2SW4G4VG43UQ5JCHYRLCVD6UT6","target":"record","payload":{"canonical_record":{"source":{"id":"2504.06981","kind":"arxiv","version":2},"metadata":{"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"eess.SY","submitted_at":"2025-04-09T15:37:02Z","cross_cats_sorted":["cs.SY"],"title_canon_sha256":"3af0f7216862fb67e892f5c068b1c7273aa96e0d8d41c37cedbce8de7c2708b1","abstract_canon_sha256":"3f45111251bcd922d4a89564a42c0cc55f9769106cc7c3c4acc9ec78222bfd88"},"schema_version":"1.0"},"canonical_sha256":"d4adc372a6e6e90ea447c4562a8fd49f82caf501ef24eb7c2f7f9024d2ceb51d","receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-06-03T01:05:43.827924Z","signature_b64":"ejIRwMSk7lMN7uo4jTcPYYTE0eLOaKX+j5bzk1bOPRiVIpP0JwnTqJJM4BCBkrOYr15a8iR6tMhiz64lyxidDw==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"d4adc372a6e6e90ea447c4562a8fd49f82caf501ef24eb7c2f7f9024d2ceb51d","last_reissued_at":"2026-06-03T01:05:43.827426Z","signature_status":"signed_v1","first_computed_at":"2026-06-03T01:05:43.827426Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"source_kind":"arxiv","source_id":"2504.06981","source_version":2,"attestation_state":"computed"},"signer":{"signer_id":"pith.science","signer_type":"pith_registry","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"created_at":"2026-06-03T01:05:43Z","supersedes":[],"prev_event":null,"signature":{"signature_status":"signed_v1","algorithm":"ed25519","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signature_b64":"lPl2ioatxr2ITYLRfNXkG8HQcvaC56Tku8hoDaJ5Xtdf/Y2tr8MGx6Cf4spZS8HCdJAG7vLJlsQCgvR/xyc2DA==","signed_message":"open_graph_event_sha256_bytes","signed_at":"2026-06-07T16:14:16.967304Z"},"content_sha256":"79165cff862f5f253d21666fc08e8ed8d9ea755b1b876af0f11792d6a2511e4e","schema_version":"1.0","event_id":"sha256:79165cff862f5f253d21666fc08e8ed8d9ea755b1b876af0f11792d6a2511e4e"},{"event_type":"graph_snapshot","subject_pith_number":"pith:2025:2SW4G4VG43UQ5JCHYRLCVD6UT6","target":"graph","payload":{"graph_snapshot":{"paper":{"title":"LCL Resonance Analysis and Damping in Single-Loop Grid-Forming Wind Turbines","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","headline":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances.","cross_cats":["cs.SY"],"primary_cat":"eess.SY","authors_text":"Frede Blaabjerg, Ioannis Lestas, Lin Cheng, Meng Chen, Yufei Xi","submitted_at":"2025-04-09T15:37:02Z","abstract_excerpt":"A common assumption in both grid-following (GFL) and grid-forming (GFM) control systems is that they are open-loop (OL) stable in the vicinity of high-frequency resonances. Hence classical loop-shaping approaches are often used for establishing stability margins and designing active damping (AD) strategies. This paper shows that single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and rob"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and robustness at high frequencies.","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"The analysis assumes a specific small-signal model of the SL-GFM with droop-I control and LCL filter, where the open-loop poles are determined by the control structure and parameters; if the model does not accurately represent the real system dynamics or if the droop-I implementation differs, the identified instability may not hold.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"Single-loop GFM wind turbine controls with droop-I RAP can exhibit open-loop instability near LCL resonances, leading to reduced high-frequency stability margins and requiring new active damping designs.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"073615db965733a56dea0413c7f3e194d8157f629f34235d23b97ad96a0f3cd8"},"source":{"id":"2504.06981","kind":"arxiv","version":2},"verdict":{"id":"22b0cc14-1e1f-4616-ac0b-57879a087457","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-22T20:24:05.222479Z","strongest_claim":"single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and robustness at high frequencies.","one_line_summary":"Single-loop GFM wind turbine controls with droop-I RAP can exhibit open-loop instability near LCL resonances, leading to reduced high-frequency stability margins and requiring new active damping designs.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"The analysis assumes a specific small-signal model of the SL-GFM with droop-I control and LCL filter, where the open-loop poles are determined by the control structure and parameters; if the model does not accurately represent the real system dynamics or if the droop-I implementation differs, the identified instability may not hold.","pith_extraction_headline":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances."},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/2504.06981/integrity.json","findings":[],"available":true,"detectors_run":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938"},"references":{"count":30,"sample":[{"doi":"","year":2024,"title":"M. Chen, D. Zhou, A. Tayyebi, E. Prieto-Araujo, F. D ¨orfler, and F. Blaabjerg, “On power control of grid-forming converters: Modeling, 10 0.9999 1 1.0001 1.0002 0.47 0.5 0.53 0 3 6 9 12 15 18 21 24 2","work_id":"536e2666-8b91-46b4-b9ba-ff104930b788","ref_index":1,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2024,"title":"Simultaneous assessment of multiple aspects of stability of power systems with renewable generation,","work_id":"441fe37a-b46d-4e61-b300-4dac36f33583","ref_index":2,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2024,"title":"Power electronics in wind generation systems,","work_id":"08b512d0-76c0-4aee-9516-4fcc28cac862","ref_index":3,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2020,"title":"Transient stability of voltage- source converters with grid-forming control: A design-oriented study,","work_id":"4037d816-8654-4ff0-a295-cef48236bea4","ref_index":4,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2035,"title":"Modeling of grid-forming and grid-following inverters for dynamic simulation of large-scale distribution systems,","work_id":"7a25ab58-0e8d-4740-9e92-74a1f178cd09","ref_index":5,"cited_arxiv_id":"","is_internal_anchor":false}],"resolved_work":30,"snapshot_sha256":"9cd35ce0a1cd32e0396db656967eb940c81ee8fd0e460ec0f03d498b405f1b90","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"verdict_id":"22b0cc14-1e1f-4616-ac0b-57879a087457"},"signer":{"signer_id":"pith.science","signer_type":"pith_registry","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"created_at":"2026-06-03T01:05:43Z","supersedes":[],"prev_event":null,"signature":{"signature_status":"signed_v1","algorithm":"ed25519","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signature_b64":"ag2O2mlqdAPfalnn3IanEnjOACZgox2OBINapWUwlSLYB3lo3eVt+ihbCfQ1+yDEPdDpk0fhndpBiNHe69HaBw==","signed_message":"open_graph_event_sha256_bytes","signed_at":"2026-06-07T16:14:16.968461Z"},"content_sha256":"7ae22e56e7ee4ba27c38f718493a858c837731126bd422dec52aa0f23cf3d137","schema_version":"1.0","event_id":"sha256:7ae22e56e7ee4ba27c38f718493a858c837731126bd422dec52aa0f23cf3d137"}],"timestamp_proofs":[],"mirror_hints":[{"mirror_type":"https","name":"Pith Resolver","base_url":"https://pith.science","bundle_url":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/bundle.json","state_url":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/state.json","well_known_bundle_url":"https://pith.science/.well-known/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/bundle.json","status":"primary"}],"public_keys":[{"key_id":"pith-v1-2026-05","algorithm":"ed25519","format":"raw","public_key_b64":"stVStoiQhXFxp4s2pdzPNoqVNBMojDU/fJ2db5S3CbM=","public_key_hex":"b2d552b68890857171a78b36a5dccf368a953413288c353f7c9d9d6f94b709b3","fingerprint_sha256_b32_first128bits":"RVFV5Z2OI2J3ZUO7ERDEBCYNKS","fingerprint_sha256_hex":"8d4b5ee74e4693bcd1df2446408b0d54","rotates_at":null,"url":"https://pith.science/pith-signing-key.json","notes":"Pith uses this Ed25519 key to sign canonical record SHA-256 digests. Verify with: ed25519_verify(public_key, message=canonical_sha256_bytes, signature=base64decode(signature_b64))."}],"merge_version":"pith-open-graph-merge-v1","built_at":"2026-06-07T16:14:16Z","links":{"resolver":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6","bundle":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/bundle.json","state":"https://pith.science/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/state.json","well_known_bundle":"https://pith.science/.well-known/pith/2SW4G4VG43UQ5JCHYRLCVD6UT6/bundle.json"},"state":{"state_type":"pith_open_graph_state","state_version":"1.0","pith_number":"pith:2025:2SW4G4VG43UQ5JCHYRLCVD6UT6","merge_version":"pith-open-graph-merge-v1","event_count":2,"valid_event_count":2,"invalid_event_count":0,"equivocation_count":0,"current":{"canonical_record":{"metadata":{"abstract_canon_sha256":"3f45111251bcd922d4a89564a42c0cc55f9769106cc7c3c4acc9ec78222bfd88","cross_cats_sorted":["cs.SY"],"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"eess.SY","submitted_at":"2025-04-09T15:37:02Z","title_canon_sha256":"3af0f7216862fb67e892f5c068b1c7273aa96e0d8d41c37cedbce8de7c2708b1"},"schema_version":"1.0","source":{"id":"2504.06981","kind":"arxiv","version":2}},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2504.06981","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"arxiv_version","alias_value":"2504.06981v2","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2504.06981","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"pith_short_12","alias_value":"2SW4G4VG43UQ","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"pith_short_16","alias_value":"2SW4G4VG43UQ5JCH","created_at":"2026-06-03T01:05:43Z"},{"alias_kind":"pith_short_8","alias_value":"2SW4G4VG","created_at":"2026-06-03T01:05:43Z"}],"graph_snapshots":[{"event_id":"sha256:7ae22e56e7ee4ba27c38f718493a858c837731126bd422dec52aa0f23cf3d137","target":"graph","created_at":"2026-06-03T01:05:43Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"graph_snapshot":{"author_claims":{"count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","strong_count":0},"builder_version":"pith-number-builder-2026-05-17-v1","claims":{"count":4,"items":[{"attestation":"unclaimed","claim_id":"C1","kind":"strongest_claim","source":"verdict.strongest_claim","status":"machine_extracted","text":"single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and robustness at high frequencies."},{"attestation":"unclaimed","claim_id":"C2","kind":"weakest_assumption","source":"verdict.weakest_assumption","status":"machine_extracted","text":"The analysis assumes a specific small-signal model of the SL-GFM with droop-I control and LCL filter, where the open-loop poles are determined by the control structure and parameters; if the model does not accurately represent the real system dynamics or if the droop-I implementation differs, the identified instability may not hold."},{"attestation":"unclaimed","claim_id":"C3","kind":"one_line_summary","source":"verdict.one_line_summary","status":"machine_extracted","text":"Single-loop GFM wind turbine controls with droop-I RAP can exhibit open-loop instability near LCL resonances, leading to reduced high-frequency stability margins and requiring new active damping designs."},{"attestation":"unclaimed","claim_id":"C4","kind":"headline","source":"verdict.pith_extraction.headline","status":"machine_extracted","text":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances."}],"snapshot_sha256":"073615db965733a56dea0413c7f3e194d8157f629f34235d23b97ad96a0f3cd8"},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"integrity":{"available":true,"clean":true,"detectors_run":[],"endpoint":"/pith/2504.06981/integrity.json","findings":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938","summary":{"advisory":0,"by_detector":{},"critical":0,"informational":0}},"paper":{"abstract_excerpt":"A common assumption in both grid-following (GFL) and grid-forming (GFM) control systems is that they are open-loop (OL) stable in the vicinity of high-frequency resonances. Hence classical loop-shaping approaches are often used for establishing stability margins and designing active damping (AD) strategies. This paper shows that single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and rob","authors_text":"Frede Blaabjerg, Ioannis Lestas, Lin Cheng, Meng Chen, Yufei Xi","cross_cats":["cs.SY"],"headline":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances.","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"eess.SY","submitted_at":"2025-04-09T15:37:02Z","title":"LCL Resonance Analysis and Damping in Single-Loop Grid-Forming Wind Turbines"},"references":{"count":30,"internal_anchors":0,"resolved_work":30,"sample":[{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":1,"title":"M. Chen, D. Zhou, A. Tayyebi, E. Prieto-Araujo, F. D ¨orfler, and F. Blaabjerg, “On power control of grid-forming converters: Modeling, 10 0.9999 1 1.0001 1.0002 0.47 0.5 0.53 0 3 6 9 12 15 18 21 24 2","work_id":"536e2666-8b91-46b4-b9ba-ff104930b788","year":2024},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":2,"title":"Simultaneous assessment of multiple aspects of stability of power systems with renewable generation,","work_id":"441fe37a-b46d-4e61-b300-4dac36f33583","year":2024},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":3,"title":"Power electronics in wind generation systems,","work_id":"08b512d0-76c0-4aee-9516-4fcc28cac862","year":2024},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":4,"title":"Transient stability of voltage- source converters with grid-forming control: A design-oriented study,","work_id":"4037d816-8654-4ff0-a295-cef48236bea4","year":2020},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":5,"title":"Modeling of grid-forming and grid-following inverters for dynamic simulation of large-scale distribution systems,","work_id":"7a25ab58-0e8d-4740-9e92-74a1f178cd09","year":2035}],"snapshot_sha256":"9cd35ce0a1cd32e0396db656967eb940c81ee8fd0e460ec0f03d498b405f1b90"},"source":{"id":"2504.06981","kind":"arxiv","version":2},"verdict":{"created_at":"2026-05-22T20:24:05.222479Z","id":"22b0cc14-1e1f-4616-ac0b-57879a087457","model_set":{"reader":"grok-4.3"},"one_line_summary":"Single-loop GFM wind turbine controls with droop-I RAP can exhibit open-loop instability near LCL resonances, leading to reduced high-frequency stability margins and requiring new active damping designs.","pipeline_version":"pith-pipeline@v0.9.0","pith_extraction_headline":"Single-loop grid-forming controls with droop-I reactive power can produce open-loop unstable poles near LCL resonances.","strongest_claim":"single-loop GFM (SL-GFM) control schemes incorporating a widely used class of reactive power (RAP) control, referred to as droop-I control, can lead to OL unstable poles. This finding reveals a novel instability mechanism resulting in a reduced stability margin and robustness at high frequencies.","weakest_assumption":"The analysis assumes a specific small-signal model of the SL-GFM with droop-I control and LCL filter, where the open-loop poles are determined by the control structure and parameters; if the model does not accurately represent the real system dynamics or if the droop-I implementation differs, the identified instability may not hold."}},"verdict_id":"22b0cc14-1e1f-4616-ac0b-57879a087457"}}],"author_attestations":[],"timestamp_anchors":[],"storage_attestations":[],"citation_signatures":[],"replication_records":[],"corrections":[],"mirror_hints":[],"record_created":{"event_id":"sha256:79165cff862f5f253d21666fc08e8ed8d9ea755b1b876af0f11792d6a2511e4e","target":"record","created_at":"2026-06-03T01:05:43Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"attestation_state":"computed","canonical_record":{"metadata":{"abstract_canon_sha256":"3f45111251bcd922d4a89564a42c0cc55f9769106cc7c3c4acc9ec78222bfd88","cross_cats_sorted":["cs.SY"],"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"eess.SY","submitted_at":"2025-04-09T15:37:02Z","title_canon_sha256":"3af0f7216862fb67e892f5c068b1c7273aa96e0d8d41c37cedbce8de7c2708b1"},"schema_version":"1.0","source":{"id":"2504.06981","kind":"arxiv","version":2}},"canonical_sha256":"d4adc372a6e6e90ea447c4562a8fd49f82caf501ef24eb7c2f7f9024d2ceb51d","receipt":{"algorithm":"ed25519","builder_version":"pith-number-builder-2026-05-17-v1","canonical_sha256":"d4adc372a6e6e90ea447c4562a8fd49f82caf501ef24eb7c2f7f9024d2ceb51d","first_computed_at":"2026-06-03T01:05:43.827426Z","key_id":"pith-v1-2026-05","kind":"pith_receipt","last_reissued_at":"2026-06-03T01:05:43.827426Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","receipt_version":"0.3","signature_b64":"ejIRwMSk7lMN7uo4jTcPYYTE0eLOaKX+j5bzk1bOPRiVIpP0JwnTqJJM4BCBkrOYr15a8iR6tMhiz64lyxidDw==","signature_status":"signed_v1","signed_at":"2026-06-03T01:05:43.827924Z","signed_message":"canonical_sha256_bytes"},"source_id":"2504.06981","source_kind":"arxiv","source_version":2}}},"equivocations":[],"invalid_events":[],"applied_event_ids":["sha256:79165cff862f5f253d21666fc08e8ed8d9ea755b1b876af0f11792d6a2511e4e","sha256:7ae22e56e7ee4ba27c38f718493a858c837731126bd422dec52aa0f23cf3d137"],"state_sha256":"c35758c7f786cecc8287ba0f891160ca9e1755503e2523f5eef9ab86bd9f8b31"},"bundle_signature":{"signature_status":"signed_v1","algorithm":"ed25519","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signature_b64":"8bEUqJlT6NQP8TwrC68jLskzWJZhUy7sgTS+CnW+m27g++7K87B7ZYJJ2ObG6ok6zRts5C/u3tE8GKEAZN3jBQ==","signed_message":"bundle_sha256_bytes","signed_at":"2026-06-07T16:14:16.973056Z","bundle_sha256":"80f26fd4f34aad13316be6062b6f89fd1b99c7559f562fbedeec114a706230e9"}}