{"state_type":"pith_open_graph_state","state_version":"1.0","pith_number":"pith:2026:3C6YFQMS2UV35UDJKUN4TTOAWT","merge_version":"pith-open-graph-merge-v1","event_count":2,"valid_event_count":2,"invalid_event_count":0,"equivocation_count":0,"current":{"canonical_record":{"metadata":{"abstract_canon_sha256":"3383d281d8606ec7d5bf84d1dabb14023ee93a9cb528c2a79db2b8da60127a12","cross_cats_sorted":[],"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"physics.optics","submitted_at":"2026-02-17T23:11:23Z","title_canon_sha256":"0a86b6cc8400cc1a441ae33e03382d6c209d1955cddae5160b4955d964ee9f7a"},"schema_version":"1.0","source":{"id":"2602.16079","kind":"arxiv","version":2}},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2602.16079","created_at":"2026-05-17T23:39:16Z"},{"alias_kind":"arxiv_version","alias_value":"2602.16079v2","created_at":"2026-05-17T23:39:16Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2602.16079","created_at":"2026-05-17T23:39:16Z"},{"alias_kind":"pith_short_12","alias_value":"3C6YFQMS2UV3","created_at":"2026-05-18T12:33:37Z"},{"alias_kind":"pith_short_16","alias_value":"3C6YFQMS2UV35UDJ","created_at":"2026-05-18T12:33:37Z"},{"alias_kind":"pith_short_8","alias_value":"3C6YFQMS","created_at":"2026-05-18T12:33:37Z"}],"graph_snapshots":[{"event_id":"sha256:0a20746a1b8ce4920c0cab4465771484736ecdb44086cbad6080d1cadc872dbb","target":"graph","created_at":"2026-05-17T23:39:16Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"graph_snapshot":{"author_claims":{"count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","strong_count":0},"builder_version":"pith-number-builder-2026-05-17-v1","claims":{"count":4,"items":[{"attestation":"unclaimed","claim_id":"C1","kind":"strongest_claim","source":"verdict.strongest_claim","status":"machine_extracted","text":"Chem-SIM preserves full vibrational fingerprints, achieves SIM-grade lateral resolution in a high-throughput camera-based format, and distinguishes stationary- from log-phase bacteria through chemical content mapping while reporting deuterated fatty-acid incorporation and lipid-droplet dynamics in live cells."},{"attestation":"unclaimed","claim_id":"C2","kind":"weakest_assumption","source":"verdict.weakest_assumption","status":"machine_extracted","text":"The assumption that the weak IR-induced fluorescence intensity change can be accurately recovered from low-photon-budget data via Poisson maximum-likelihood demodulation and spectral normalization without introducing artifacts that distort the chemical fingerprints."},{"attestation":"unclaimed","claim_id":"C3","kind":"one_line_summary","source":"verdict.one_line_summary","status":"machine_extracted","text":"Chem-SIM achieves super-resolved chemical imaging of cells by demodulating photothermal modulation of structured-illumination fluorescence to extract vibrational spectra."},{"attestation":"unclaimed","claim_id":"C4","kind":"headline","source":"verdict.pith_extraction.headline","status":"machine_extracted","text":"Chem-SIM recovers full vibrational fingerprints at SIM-grade resolution by photothermal modulation of structured-illumination fluorescence."}],"snapshot_sha256":"be6edf65c577bce52a64a138500f894af2f4bd9ca7f3ea71fe79e63b5404cefa"},"formal_canon":{"evidence_count":1,"snapshot_sha256":"f1f9f092ff76bdf16df1097383983d050fe09c14003410fd65d9030faf6c3243"},"paper":{"abstract_excerpt":"Structured illumination microscopy (SIM) has attained high spatiotemporal delineation of subcellular architecture, yet offers limited insight into chemical composition. We develop Chem-SIM, a structured-illumination fluorescence detected mid-infrared photothermal microscopy, for super-resolved chemical imaging of microorganisms and mammalian cells. Poisson maximum-likelihood demodulation and spectral normalization across wavenumber recover the weak IR-induced fluorescence intensity change under low photon budgets and convert the fluorescence intensity modulation to chemical fingerprints. Photo","authors_text":"Biwen Gao, Danchen Jia, Dashan Dong, George Abu-Aqil, Jianpeng Ao, Ji-Xin Cheng, Meng Zhang, Qing Xia, Xinyan Teng","cross_cats":[],"headline":"Chem-SIM recovers full vibrational fingerprints at SIM-grade resolution by photothermal modulation of structured-illumination fluorescence.","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"physics.optics","submitted_at":"2026-02-17T23:11:23Z","title":"Chem-SIM: Super-resolution Chemical Imaging via Photothermal Modulation of Structured-Illumination Fluorescence"},"references":{"count":47,"internal_anchors":1,"resolved_work":47,"sample":[{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":1,"title":"Valm, A.M. et al. Applying systems -level spectral imaging and analysis to reveal the organelle interactome. Nature 546, 162-167 (2017)","work_id":"fbcb2664-e998-4c73-9de9-58f9cd844936","year":2017},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":2,"title":"Bar-Peled, L. & Kory, N. Principles and functions of metabolic compartmentalization. Nature Metabolism 4, 1232-1244 (2022). 14","work_id":"3ceb55a2-b211-4e21-a85b-1fa9243cb8aa","year":2022},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":3,"title":"Huang, B., Bates, M. & Zhuang, X. Super -Resolution Fluorescence Microscopy. Annual Review of Biochemistry 78, 993-1016 (2009)","work_id":"726819e2-af78-4ddf-948d-6507831e977b","year":2009},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":4,"title":"Surpassing the late ral resolution limit by a factor of two using structured illumination microscopy","work_id":"75a050d6-8fb7-4b72-940b-2eca8ba0f0bd","year":2000},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":5,"title":"Wu, Y. & Shroff, H. Faster, sharper, and deeper: structured illumination microscopy for biological imaging. Nature Methods 15, 1011-1019 (2018)","work_id":"f50e1116-c412-4e12-ae9f-6f6836ed8f1a","year":2018}],"snapshot_sha256":"aa3bccfc998028a47df52d8a0b4e2fe19c4a680c8fa652a7a2805913a822d5e4"},"source":{"id":"2602.16079","kind":"arxiv","version":2},"verdict":{"created_at":"2026-05-15T21:18:31.427686Z","id":"f080320a-0132-4798-b181-5f10de5ea9e6","model_set":{"reader":"grok-4.3"},"one_line_summary":"Chem-SIM achieves super-resolved chemical imaging of cells by demodulating photothermal modulation of structured-illumination fluorescence to extract vibrational spectra.","pipeline_version":"pith-pipeline@v0.9.0","pith_extraction_headline":"Chem-SIM recovers full vibrational fingerprints at SIM-grade resolution by photothermal modulation of structured-illumination fluorescence.","strongest_claim":"Chem-SIM preserves full vibrational fingerprints, achieves SIM-grade lateral resolution in a high-throughput camera-based format, and distinguishes stationary- from log-phase bacteria through chemical content mapping while reporting deuterated fatty-acid incorporation and lipid-droplet dynamics in live cells.","weakest_assumption":"The assumption that the weak IR-induced fluorescence intensity change can be accurately recovered from low-photon-budget data via Poisson maximum-likelihood demodulation and spectral normalization without introducing artifacts that distort the chemical fingerprints."}},"verdict_id":"f080320a-0132-4798-b181-5f10de5ea9e6"}}],"author_attestations":[],"timestamp_anchors":[],"storage_attestations":[],"citation_signatures":[],"replication_records":[],"corrections":[],"mirror_hints":[],"record_created":{"event_id":"sha256:4fbf92036b56fc193170dd41d38180a69b85682208f1cea1492601c4be8dc73d","target":"record","created_at":"2026-05-17T23:39:16Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"attestation_state":"computed","canonical_record":{"metadata":{"abstract_canon_sha256":"3383d281d8606ec7d5bf84d1dabb14023ee93a9cb528c2a79db2b8da60127a12","cross_cats_sorted":[],"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"physics.optics","submitted_at":"2026-02-17T23:11:23Z","title_canon_sha256":"0a86b6cc8400cc1a441ae33e03382d6c209d1955cddae5160b4955d964ee9f7a"},"schema_version":"1.0","source":{"id":"2602.16079","kind":"arxiv","version":2}},"canonical_sha256":"d8bd82c192d52bbed069551bc9cdc0b4e0a75bfc3c38ca86e035b5ff05c1033a","receipt":{"algorithm":"ed25519","builder_version":"pith-number-builder-2026-05-17-v1","canonical_sha256":"d8bd82c192d52bbed069551bc9cdc0b4e0a75bfc3c38ca86e035b5ff05c1033a","first_computed_at":"2026-05-17T23:39:16.094949Z","key_id":"pith-v1-2026-05","kind":"pith_receipt","last_reissued_at":"2026-05-17T23:39:16.094949Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","receipt_version":"0.3","signature_b64":"YFw6vchz/0MfnTHIclAOZe+O7jvow0BYsTvEAxcLNtEGfV1QHm6xh4rY4zxiv+IbpY44MQtq9lTjzWa5xuoeDQ==","signature_status":"signed_v1","signed_at":"2026-05-17T23:39:16.095576Z","signed_message":"canonical_sha256_bytes"},"source_id":"2602.16079","source_kind":"arxiv","source_version":2}}},"equivocations":[],"invalid_events":[],"applied_event_ids":["sha256:4fbf92036b56fc193170dd41d38180a69b85682208f1cea1492601c4be8dc73d","sha256:0a20746a1b8ce4920c0cab4465771484736ecdb44086cbad6080d1cadc872dbb"],"state_sha256":"a2581f2a89772449d1ea484eb8a9b0c7d8810bf797bb9c043cf29aca2b8f54e0"}