{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2017:5D4LS67RCBYRBOQI7CQHHP3U6M","short_pith_number":"pith:5D4LS67R","schema_version":"1.0","canonical_sha256":"e8f8b97bf1107110ba08f8a073bf74f336ce3b7f2619d7860d3d20e4c19452a8","source":{"kind":"arxiv","id":"1705.08637","version":1},"attestation_state":"computed","paper":{"title":"Bright 5 - 85 MeV Compton gamma-ray pulses from GeV laser-plasma accelerator and plasma mirror","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"","cross_cats":[],"primary_cat":"physics.acc-ph","authors_text":"A. C. Bernstein, A. Hannasch, C. Wagner, E. Gaul, G. Dyer, H.-E. Tsai, J. Gordon, J. M. Shaw, J. Welch, K. Weichman, M. C. Downer, M. Donovan, M. LaBerge, M. Martinez, M. Spinks, N. Fazel, R. Zgadzaj, T. Ditmire, T. Toncian, W. Henderson, X. Wang, Y. Y. Chang","submitted_at":"2017-05-24T07:20:07Z","abstract_excerpt":"We convert a GeV laser-plasma electron accelerator into a compact femtosecond-pulsed $\\gamma$-ray source by inserting a $100 \\mu$m-thick glass plate $\\sim3$ cm after the accelerator exit. With near-unity reliability, and requiring only crude alignment, this glass plasma mirror retro-reflected spent drive laser pulses (photon energy $\\hbar\\omega_L = 1.17$ eV) with $>50\\%$ efficiency back onto trailing electrons (peak Lorentz factor $1000 < \\gamma_e < 4400$), creating an optical undulator that generated $\\sim10^8 \\gamma$-ray photons with sub-mrad divergence, estimated peak brilliance $\\sim10^{21"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":false,"formal_links_present":false},"canonical_record":{"source":{"id":"1705.08637","kind":"arxiv","version":1},"metadata":{"license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"physics.acc-ph","submitted_at":"2017-05-24T07:20:07Z","cross_cats_sorted":[],"title_canon_sha256":"95c303454fcb5ad88673368f63239fe13974636e052f54f2072ef71a84e3189c","abstract_canon_sha256":"95aa0b71eeb5ada0886ad840c8a01effb7cb15ad516666845fe9597f883f4361"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-05-18T00:43:44.699231Z","signature_b64":"0H9c5+i5JjGx0IS2LJZ8mCP5G5zj45yhjuh8i7ApKPpqTJMtO5P/aad2jB0sDIveyZcIwtDgX3L5hHXFr7FPDw==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"e8f8b97bf1107110ba08f8a073bf74f336ce3b7f2619d7860d3d20e4c19452a8","last_reissued_at":"2026-05-18T00:43:44.698719Z","signature_status":"signed_v1","first_computed_at":"2026-05-18T00:43:44.698719Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"Bright 5 - 85 MeV Compton gamma-ray pulses from GeV laser-plasma accelerator and plasma mirror","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"","cross_cats":[],"primary_cat":"physics.acc-ph","authors_text":"A. C. Bernstein, A. Hannasch, C. Wagner, E. Gaul, G. Dyer, H.-E. Tsai, J. Gordon, J. M. Shaw, J. Welch, K. Weichman, M. C. Downer, M. Donovan, M. LaBerge, M. Martinez, M. Spinks, N. Fazel, R. Zgadzaj, T. Ditmire, T. Toncian, W. Henderson, X. Wang, Y. Y. Chang","submitted_at":"2017-05-24T07:20:07Z","abstract_excerpt":"We convert a GeV laser-plasma electron accelerator into a compact femtosecond-pulsed $\\gamma$-ray source by inserting a $100 \\mu$m-thick glass plate $\\sim3$ cm after the accelerator exit. With near-unity reliability, and requiring only crude alignment, this glass plasma mirror retro-reflected spent drive laser pulses (photon energy $\\hbar\\omega_L = 1.17$ eV) with $>50\\%$ efficiency back onto trailing electrons (peak Lorentz factor $1000 < \\gamma_e < 4400$), creating an optical undulator that generated $\\sim10^8 \\gamma$-ray photons with sub-mrad divergence, estimated peak brilliance $\\sim10^{21"},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"1705.08637","kind":"arxiv","version":1},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"1705.08637","created_at":"2026-05-18T00:43:44.698801+00:00"},{"alias_kind":"arxiv_version","alias_value":"1705.08637v1","created_at":"2026-05-18T00:43:44.698801+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.1705.08637","created_at":"2026-05-18T00:43:44.698801+00:00"},{"alias_kind":"pith_short_12","alias_value":"5D4LS67RCBYR","created_at":"2026-05-18T12:31:00.734936+00:00"},{"alias_kind":"pith_short_16","alias_value":"5D4LS67RCBYRBOQI","created_at":"2026-05-18T12:31:00.734936+00:00"},{"alias_kind":"pith_short_8","alias_value":"5D4LS67R","created_at":"2026-05-18T12:31:00.734936+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":1,"internal_anchor_count":1,"sample":[{"citing_arxiv_id":"1907.02239","citing_title":"Accurate single-shot measurement technique for the spectral distribution of GeV electron beams from a laser wakefield accelerator","ref_index":18,"is_internal_anchor":true}]},"formal_canon":{"evidence_count":0,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M","json":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M.json","graph_json":"https://pith.science/api/pith-number/5D4LS67RCBYRBOQI7CQHHP3U6M/graph.json","events_json":"https://pith.science/api/pith-number/5D4LS67RCBYRBOQI7CQHHP3U6M/events.json","paper":"https://pith.science/paper/5D4LS67R"},"agent_actions":{"view_html":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M","download_json":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M.json","view_paper":"https://pith.science/paper/5D4LS67R","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=1705.08637&json=true","fetch_graph":"https://pith.science/api/pith-number/5D4LS67RCBYRBOQI7CQHHP3U6M/graph.json","fetch_events":"https://pith.science/api/pith-number/5D4LS67RCBYRBOQI7CQHHP3U6M/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M/action/timestamp_anchor","attest_storage":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M/action/storage_attestation","attest_author":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M/action/author_attestation","sign_citation":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M/action/citation_signature","submit_replication":"https://pith.science/pith/5D4LS67RCBYRBOQI7CQHHP3U6M/action/replication_record"}},"created_at":"2026-05-18T00:43:44.698801+00:00","updated_at":"2026-05-18T00:43:44.698801+00:00"}