{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:1998:AQH57TWM44ZFSGG6TITN7Q2E7P","short_pith_number":"pith:AQH57TWM","schema_version":"1.0","canonical_sha256":"040fdfcecce7325918de9a26dfc344fbfb2ce8227364b4db53218d9431794afc","source":{"kind":"arxiv","id":"physics/9801033","version":1},"attestation_state":"computed","paper":{"title":"A 10 MHz beam counter and a multiplicity detector for the E864 spectrometer","license":"","headline":"","cross_cats":[],"primary_cat":"physics.ins-det","authors_text":"G. Van Buren, I.A. Pless, J. Tomasi, K. Barish, M.S.Z. Rabin, P. Haridas, R.D. Majka","submitted_at":"1998-01-30T18:27:51Z","abstract_excerpt":"The E864 experiment at BNL requires a beam counter and multiplicity detector system that can perform at an incident beam rate of 10^7 Au ions per second. We have developed and tested a 150 micrometer thick quartz Cherenkov beam counter and a scintillator based multiplicity-trigger counter during the first run of this experiment in 1994. We obtained a time resolution of 78 ps for the beam counter at an incident beam rate 5 x 10^5 Hz and 100 ps at a rate of 1 x 10^7 Hz. Pulse height discrimination is used to obtain a minimum bias and a 10% centrality trigger from the multiplicity detectors. The "},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":false,"formal_links_present":false},"canonical_record":{"source":{"id":"physics/9801033","kind":"arxiv","version":1},"metadata":{"license":"","primary_cat":"physics.ins-det","submitted_at":"1998-01-30T18:27:51Z","cross_cats_sorted":[],"title_canon_sha256":"e7c0d7adc98d7a98d9b85e9225b21a2b0f24031bde37daf652fd891d474f630a","abstract_canon_sha256":"c25ad4949fffa3dd6e2ca37b24c7febe7b7bf68dbd9a66c84eb3b30b46736744"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-07-04T16:10:22.395539Z","signature_b64":"WhEtF+yBZlpiGv7SfnokZK36kx93WNh+eJlFMBPz+uutLjqEPVknNHBsScexNJLzQDX6zFSiNDpbbiMzD//UCQ==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"040fdfcecce7325918de9a26dfc344fbfb2ce8227364b4db53218d9431794afc","last_reissued_at":"2026-07-04T16:10:22.395115Z","signature_status":"signed_v1","first_computed_at":"2026-07-04T16:10:22.395115Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"A 10 MHz beam counter and a multiplicity detector for the E864 spectrometer","license":"","headline":"","cross_cats":[],"primary_cat":"physics.ins-det","authors_text":"G. Van Buren, I.A. Pless, J. Tomasi, K. Barish, M.S.Z. Rabin, P. Haridas, R.D. Majka","submitted_at":"1998-01-30T18:27:51Z","abstract_excerpt":"The E864 experiment at BNL requires a beam counter and multiplicity detector system that can perform at an incident beam rate of 10^7 Au ions per second. We have developed and tested a 150 micrometer thick quartz Cherenkov beam counter and a scintillator based multiplicity-trigger counter during the first run of this experiment in 1994. We obtained a time resolution of 78 ps for the beam counter at an incident beam rate 5 x 10^5 Hz and 100 ps at a rate of 1 x 10^7 Hz. Pulse height discrimination is used to obtain a minimum bias and a 10% centrality trigger from the multiplicity detectors. The "},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"physics/9801033","kind":"arxiv","version":1},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/physics/9801033/integrity.json","findings":[],"available":true,"detectors_run":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938"},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"physics/9801033","created_at":"2026-07-04T16:10:22.395177+00:00"},{"alias_kind":"arxiv_version","alias_value":"physics/9801033v1","created_at":"2026-07-04T16:10:22.395177+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.physics/9801033","created_at":"2026-07-04T16:10:22.395177+00:00"},{"alias_kind":"pith_short_12","alias_value":"AQH57TWM44ZF","created_at":"2026-07-04T16:10:22.395177+00:00"},{"alias_kind":"pith_short_16","alias_value":"AQH57TWM44ZFSGG6","created_at":"2026-07-04T16:10:22.395177+00:00"},{"alias_kind":"pith_short_8","alias_value":"AQH57TWM","created_at":"2026-07-04T16:10:22.395177+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":0,"internal_anchor_count":0,"sample":[]},"formal_canon":{"evidence_count":0,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P","json":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P.json","graph_json":"https://pith.science/api/pith-number/AQH57TWM44ZFSGG6TITN7Q2E7P/graph.json","events_json":"https://pith.science/api/pith-number/AQH57TWM44ZFSGG6TITN7Q2E7P/events.json","paper":"https://pith.science/paper/AQH57TWM"},"agent_actions":{"view_html":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P","download_json":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P.json","view_paper":"https://pith.science/paper/AQH57TWM","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=physics/9801033&json=true","fetch_graph":"https://pith.science/api/pith-number/AQH57TWM44ZFSGG6TITN7Q2E7P/graph.json","fetch_events":"https://pith.science/api/pith-number/AQH57TWM44ZFSGG6TITN7Q2E7P/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P/action/timestamp_anchor","attest_storage":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P/action/storage_attestation","attest_author":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P/action/author_attestation","sign_citation":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P/action/citation_signature","submit_replication":"https://pith.science/pith/AQH57TWM44ZFSGG6TITN7Q2E7P/action/replication_record"}},"created_at":"2026-07-04T16:10:22.395177+00:00","updated_at":"2026-07-04T16:10:22.395177+00:00"}