{"bundle_type":"pith_open_graph_bundle","bundle_version":"1.0","pith_number":"pith:2026:B5TK7SZ6GVUTQZYHXPHGFUQ4VU","short_pith_number":"pith:B5TK7SZ6","canonical_record":{"source":{"id":"2604.17953","kind":"arxiv","version":2},"metadata":{"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-04-20T08:35:26Z","cross_cats_sorted":[],"title_canon_sha256":"494a1796117331011ba0355d949629be071579e3d4dd223eedf204f8e60ed53e","abstract_canon_sha256":"3f83f44fbb7874f49209f16f56686989b133d9531dfee7d44f548e217a6f7fb6"},"schema_version":"1.0"},"canonical_sha256":"0f66afcb3e3569386707bbce62d21cad24e66dd063029d96cffc2708a4011bbb","source":{"kind":"arxiv","id":"2604.17953","version":2},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2604.17953","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"arxiv_version","alias_value":"2604.17953v2","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2604.17953","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"pith_short_12","alias_value":"B5TK7SZ6GVUT","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"pith_short_16","alias_value":"B5TK7SZ6GVUTQZYH","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"pith_short_8","alias_value":"B5TK7SZ6","created_at":"2026-07-01T01:17:50Z"}],"events":[{"event_type":"record_created","subject_pith_number":"pith:2026:B5TK7SZ6GVUTQZYHXPHGFUQ4VU","target":"record","payload":{"canonical_record":{"source":{"id":"2604.17953","kind":"arxiv","version":2},"metadata":{"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-04-20T08:35:26Z","cross_cats_sorted":[],"title_canon_sha256":"494a1796117331011ba0355d949629be071579e3d4dd223eedf204f8e60ed53e","abstract_canon_sha256":"3f83f44fbb7874f49209f16f56686989b133d9531dfee7d44f548e217a6f7fb6"},"schema_version":"1.0"},"canonical_sha256":"0f66afcb3e3569386707bbce62d21cad24e66dd063029d96cffc2708a4011bbb","receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-07-01T01:17:50.958435Z","signature_b64":"QbiUiRW6JRMaIKeGsnL6VKH3ObXjMINdAr3K0qKipkyiLzHWaaao8htc0ocCPRFzY8kSrSEKecSNJZEjx5PqCw==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"0f66afcb3e3569386707bbce62d21cad24e66dd063029d96cffc2708a4011bbb","last_reissued_at":"2026-07-01T01:17:50.958004Z","signature_status":"signed_v1","first_computed_at":"2026-07-01T01:17:50.958004Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"source_kind":"arxiv","source_id":"2604.17953","source_version":2,"attestation_state":"computed"},"signer":{"signer_id":"pith.science","signer_type":"pith_registry","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"created_at":"2026-07-01T01:17:50Z","supersedes":[],"prev_event":null,"signature":{"signature_status":"signed_v1","algorithm":"ed25519","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signature_b64":"2eAXnvibnW4tOlUBEaSeqYwJk/8tBJ102dw1aBIJ/a+iAHU/Zv4gj14XpoByylX+74D2BlVsSDcTR3U605lNAw==","signed_message":"open_graph_event_sha256_bytes","signed_at":"2026-08-11T09:48:18.078879Z"},"content_sha256":"14719e0dedca4d512fcf5257735d81ae9c785cfd7e7bee4965cff76922e9d3b3","schema_version":"1.0","event_id":"sha256:14719e0dedca4d512fcf5257735d81ae9c785cfd7e7bee4965cff76922e9d3b3"},{"event_type":"graph_snapshot","subject_pith_number":"pith:2026:B5TK7SZ6GVUTQZYHXPHGFUQ4VU","target":"graph","payload":{"graph_snapshot":{"paper":{"title":"Advances in photocathode development for PICOSEC Micromegas precise-timing detectors","license":"http://creativecommons.org/licenses/by/4.0/","headline":"A 5 nm Cesium Iodide photocathode achieves 10.9 picosecond time resolution in the PICOSEC Micromegas detector.","cross_cats":[],"primary_cat":"physics.ins-det","authors_text":"A. Breskin, A. Gurpinar, A. Kallitsopoulou, A. Utrobicic, B. Schoenfelder, D. Janssens, D. J. G. Marques, D. Sampsonidis, D. Zavazieva, E. Jelinkova, E. Oliveri, E. Scorsone, F. Garcia, F. Guerra, F. M. Brunbauer, G. Fanourakis, H. Muller, I. Giomataris, I. Karakoulias, I. Vai, J. Bortfeldt, J. Datta, J. Liu, K. J. Floethner, L. Ropelewski, L. Viezzi, M. Brunoldi, M. Gallinaro, M. Kovacic, M. Lisowska, M. Lupberger, M. Pomorski, M. van Stenis, P. Legou, P. Vitulo, R. Aleksan, R. De Oliveira, R. Veenhof, S. Aune, S. Ferry, S. Tzamarias, S. White, T. Papaevangelou, T. Schneider, X. Wang, Y. Meng, Y. Tsipolitis, Y. Zhou, Z. Zhang","submitted_at":"2026-04-20T08:35:26Z","abstract_excerpt":"The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The st"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"The best performance was delivered by a 5 nm Cesium Iodide (CsI) photocathode, reaching σ = 10.9 ± 0.3 ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date.","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"That laboratory optical measurements and short beam-test exposures with 150 GeV muons adequately predict long-term stability and performance under the radiation, gas, and high-rate conditions of actual collider experiments.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"A 5 nm CsI photocathode achieves 10.9 ps time resolution with over 30 photoelectrons in PICOSEC Micromegas, while Ti and B4C offer robust options at ~30 ps.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"A 5 nm Cesium Iodide photocathode achieves 10.9 picosecond time resolution in the PICOSEC Micromegas detector.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"25416df5ebad34dbf9ae525bbbbb9e73be15c5b93fcbd6d87e377545e7676f81"},"source":{"id":"2604.17953","kind":"arxiv","version":2},"verdict":{"id":"952cb74e-db86-4a14-8cd0-ff9c439e8d3a","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-10T03:51:12.919346Z","strongest_claim":"The best performance was delivered by a 5 nm Cesium Iodide (CsI) photocathode, reaching σ = 10.9 ± 0.3 ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date.","one_line_summary":"A 5 nm CsI photocathode achieves 10.9 ps time resolution with over 30 photoelectrons in PICOSEC Micromegas, while Ti and B4C offer robust options at ~30 ps.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"That laboratory optical measurements and short beam-test exposures with 150 GeV muons adequately predict long-term stability and performance under the radiation, gas, and high-rate conditions of actual collider experiments.","pith_extraction_headline":"A 5 nm Cesium Iodide photocathode achieves 10.9 picosecond time resolution in the PICOSEC Micromegas detector."},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/2604.17953/integrity.json","findings":[],"available":true,"detectors_run":[{"name":"doi_compliance","ran_at":"2026-05-20T04:35:31.678289Z","status":"completed","version":"1.0.0","findings_count":0}],"snapshot_sha256":"a942a954b8c7ebf15fab2872670b2e24b13fc73fb0614995141bdf41b28f0f5a"},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"verdict_id":"952cb74e-db86-4a14-8cd0-ff9c439e8d3a"},"signer":{"signer_id":"pith.science","signer_type":"pith_registry","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"created_at":"2026-07-01T01:17:50Z","supersedes":[],"prev_event":null,"signature":{"signature_status":"signed_v1","algorithm":"ed25519","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signature_b64":"1+lKeln7R4BDddWb0f/XjAN4RvX4vH9zW5z8lxJ/tz9yLF0NMyrSzAC9en1pg8B80o+WMm1neUAQQGn7Lwy3AA==","signed_message":"open_graph_event_sha256_bytes","signed_at":"2026-08-11T09:48:18.079814Z"},"content_sha256":"1d5227ac24a3c0d0a97affef7eabc7909c18b9d513a635ce6a7dbd2dfbd858a9","schema_version":"1.0","event_id":"sha256:1d5227ac24a3c0d0a97affef7eabc7909c18b9d513a635ce6a7dbd2dfbd858a9"}],"timestamp_proofs":[],"mirror_hints":[{"mirror_type":"https","name":"Pith Resolver","base_url":"https://pith.science","bundle_url":"https://pith.science/pith/B5TK7SZ6GVUTQZYHXPHGFUQ4VU/bundle.json","state_url":"https://pith.science/pith/B5TK7SZ6GVUTQZYHXPHGFUQ4VU/state.json","well_known_bundle_url":"https://pith.science/.well-known/pith/B5TK7SZ6GVUTQZYHXPHGFUQ4VU/bundle.json","status":"primary"}],"public_keys":[{"key_id":"pith-v1-2026-05","algorithm":"ed25519","format":"raw","public_key_b64":"stVStoiQhXFxp4s2pdzPNoqVNBMojDU/fJ2db5S3CbM=","public_key_hex":"b2d552b68890857171a78b36a5dccf368a953413288c353f7c9d9d6f94b709b3","fingerprint_sha256_b32_first128bits":"RVFV5Z2OI2J3ZUO7ERDEBCYNKS","fingerprint_sha256_hex":"8d4b5ee74e4693bcd1df2446408b0d54","rotates_at":null,"url":"https://pith.science/pith-signing-key.json","notes":"Pith uses this Ed25519 key to sign canonical record SHA-256 digests. Verify with: ed25519_verify(public_key, message=canonical_sha256_bytes, signature=base64decode(signature_b64))."}],"merge_version":"pith-open-graph-merge-v1","built_at":"2026-08-11T09:48:18Z","links":{"resolver":"https://pith.science/pith/B5TK7SZ6GVUTQZYHXPHGFUQ4VU","bundle":"https://pith.science/pith/B5TK7SZ6GVUTQZYHXPHGFUQ4VU/bundle.json","state":"https://pith.science/pith/B5TK7SZ6GVUTQZYHXPHGFUQ4VU/state.json","well_known_bundle":"https://pith.science/.well-known/pith/B5TK7SZ6GVUTQZYHXPHGFUQ4VU/bundle.json"},"state":{"state_type":"pith_open_graph_state","state_version":"1.0","pith_number":"pith:2026:B5TK7SZ6GVUTQZYHXPHGFUQ4VU","merge_version":"pith-open-graph-merge-v1","event_count":2,"valid_event_count":2,"invalid_event_count":0,"equivocation_count":0,"current":{"canonical_record":{"metadata":{"abstract_canon_sha256":"3f83f44fbb7874f49209f16f56686989b133d9531dfee7d44f548e217a6f7fb6","cross_cats_sorted":[],"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-04-20T08:35:26Z","title_canon_sha256":"494a1796117331011ba0355d949629be071579e3d4dd223eedf204f8e60ed53e"},"schema_version":"1.0","source":{"id":"2604.17953","kind":"arxiv","version":2}},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2604.17953","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"arxiv_version","alias_value":"2604.17953v2","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2604.17953","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"pith_short_12","alias_value":"B5TK7SZ6GVUT","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"pith_short_16","alias_value":"B5TK7SZ6GVUTQZYH","created_at":"2026-07-01T01:17:50Z"},{"alias_kind":"pith_short_8","alias_value":"B5TK7SZ6","created_at":"2026-07-01T01:17:50Z"}],"graph_snapshots":[{"event_id":"sha256:1d5227ac24a3c0d0a97affef7eabc7909c18b9d513a635ce6a7dbd2dfbd858a9","target":"graph","created_at":"2026-07-01T01:17:50Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"graph_snapshot":{"author_claims":{"count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","strong_count":0},"builder_version":"pith-number-builder-2026-05-17-v1","claims":{"count":4,"items":[{"attestation":"unclaimed","claim_id":"C1","kind":"strongest_claim","source":"verdict.strongest_claim","status":"machine_extracted","text":"The best performance was delivered by a 5 nm Cesium Iodide (CsI) photocathode, reaching σ = 10.9 ± 0.3 ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date."},{"attestation":"unclaimed","claim_id":"C2","kind":"weakest_assumption","source":"verdict.weakest_assumption","status":"machine_extracted","text":"That laboratory optical measurements and short beam-test exposures with 150 GeV muons adequately predict long-term stability and performance under the radiation, gas, and high-rate conditions of actual collider experiments."},{"attestation":"unclaimed","claim_id":"C3","kind":"one_line_summary","source":"verdict.one_line_summary","status":"machine_extracted","text":"A 5 nm CsI photocathode achieves 10.9 ps time resolution with over 30 photoelectrons in PICOSEC Micromegas, while Ti and B4C offer robust options at ~30 ps."},{"attestation":"unclaimed","claim_id":"C4","kind":"headline","source":"verdict.pith_extraction.headline","status":"machine_extracted","text":"A 5 nm Cesium Iodide photocathode achieves 10.9 picosecond time resolution in the PICOSEC Micromegas detector."}],"snapshot_sha256":"25416df5ebad34dbf9ae525bbbbb9e73be15c5b93fcbd6d87e377545e7676f81"},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"integrity":{"available":true,"clean":true,"detectors_run":[{"findings_count":0,"name":"doi_compliance","ran_at":"2026-05-20T04:35:31.678289Z","status":"completed","version":"1.0.0"}],"endpoint":"/pith/2604.17953/integrity.json","findings":[],"snapshot_sha256":"a942a954b8c7ebf15fab2872670b2e24b13fc73fb0614995141bdf41b28f0f5a","summary":{"advisory":0,"by_detector":{},"critical":0,"informational":0}},"paper":{"abstract_excerpt":"The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The st","authors_text":"A. Breskin, A. Gurpinar, A. Kallitsopoulou, A. Utrobicic, B. Schoenfelder, D. Janssens, D. J. G. Marques, D. Sampsonidis, D. Zavazieva, E. Jelinkova, E. Oliveri, E. Scorsone, F. Garcia, F. Guerra, F. M. Brunbauer, G. Fanourakis, H. Muller, I. Giomataris, I. Karakoulias, I. Vai, J. Bortfeldt, J. Datta, J. Liu, K. J. Floethner, L. Ropelewski, L. Viezzi, M. Brunoldi, M. Gallinaro, M. Kovacic, M. Lisowska, M. Lupberger, M. Pomorski, M. van Stenis, P. Legou, P. Vitulo, R. Aleksan, R. De Oliveira, R. Veenhof, S. Aune, S. Ferry, S. Tzamarias, S. White, T. Papaevangelou, T. Schneider, X. Wang, Y. Meng, Y. Tsipolitis, Y. Zhou, Z. Zhang","cross_cats":[],"headline":"A 5 nm Cesium Iodide photocathode achieves 10.9 picosecond time resolution in the PICOSEC Micromegas detector.","license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-04-20T08:35:26Z","title":"Advances in photocathode development for PICOSEC Micromegas precise-timing detectors"},"references":{"count":0,"internal_anchors":0,"resolved_work":0,"sample":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"2604.17953","kind":"arxiv","version":2},"verdict":{"created_at":"2026-05-10T03:51:12.919346Z","id":"952cb74e-db86-4a14-8cd0-ff9c439e8d3a","model_set":{"reader":"grok-4.3"},"one_line_summary":"A 5 nm CsI photocathode achieves 10.9 ps time resolution with over 30 photoelectrons in PICOSEC Micromegas, while Ti and B4C offer robust options at ~30 ps.","pipeline_version":"pith-pipeline@v0.9.0","pith_extraction_headline":"A 5 nm Cesium Iodide photocathode achieves 10.9 picosecond time resolution in the PICOSEC Micromegas detector.","strongest_claim":"The best performance was delivered by a 5 nm Cesium Iodide (CsI) photocathode, reaching σ = 10.9 ± 0.3 ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date.","weakest_assumption":"That laboratory optical measurements and short beam-test exposures with 150 GeV muons adequately predict long-term stability and performance under the radiation, gas, and high-rate conditions of actual collider experiments."}},"verdict_id":"952cb74e-db86-4a14-8cd0-ff9c439e8d3a"}}],"author_attestations":[],"timestamp_anchors":[],"storage_attestations":[],"citation_signatures":[],"replication_records":[],"corrections":[],"mirror_hints":[],"record_created":{"event_id":"sha256:14719e0dedca4d512fcf5257735d81ae9c785cfd7e7bee4965cff76922e9d3b3","target":"record","created_at":"2026-07-01T01:17:50Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"attestation_state":"computed","canonical_record":{"metadata":{"abstract_canon_sha256":"3f83f44fbb7874f49209f16f56686989b133d9531dfee7d44f548e217a6f7fb6","cross_cats_sorted":[],"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-04-20T08:35:26Z","title_canon_sha256":"494a1796117331011ba0355d949629be071579e3d4dd223eedf204f8e60ed53e"},"schema_version":"1.0","source":{"id":"2604.17953","kind":"arxiv","version":2}},"canonical_sha256":"0f66afcb3e3569386707bbce62d21cad24e66dd063029d96cffc2708a4011bbb","receipt":{"algorithm":"ed25519","builder_version":"pith-number-builder-2026-05-17-v1","canonical_sha256":"0f66afcb3e3569386707bbce62d21cad24e66dd063029d96cffc2708a4011bbb","first_computed_at":"2026-07-01T01:17:50.958004Z","key_id":"pith-v1-2026-05","kind":"pith_receipt","last_reissued_at":"2026-07-01T01:17:50.958004Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","receipt_version":"0.3","signature_b64":"QbiUiRW6JRMaIKeGsnL6VKH3ObXjMINdAr3K0qKipkyiLzHWaaao8htc0ocCPRFzY8kSrSEKecSNJZEjx5PqCw==","signature_status":"signed_v1","signed_at":"2026-07-01T01:17:50.958435Z","signed_message":"canonical_sha256_bytes"},"source_id":"2604.17953","source_kind":"arxiv","source_version":2}}},"equivocations":[],"invalid_events":[],"applied_event_ids":["sha256:14719e0dedca4d512fcf5257735d81ae9c785cfd7e7bee4965cff76922e9d3b3","sha256:1d5227ac24a3c0d0a97affef7eabc7909c18b9d513a635ce6a7dbd2dfbd858a9"],"state_sha256":"e8992db90801683aa33c022e3c88049dbedb80d1e08a16213e78eb6e9db3287e"},"bundle_signature":{"signature_status":"signed_v1","algorithm":"ed25519","key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signature_b64":"Si5FoI5Tc/qpxW9OOhasSsAYb8EKaovJPTFaQzPNlOGH4bBoQlS6Rr4YM9WPyHzsEZmvTUxaLCrQTyg1DhUmBw==","signed_message":"bundle_sha256_bytes","signed_at":"2026-08-11T09:48:18.086466Z","bundle_sha256":"1136987c3eef75707512ec035c8ed9782fc7cd897e7621370978fd9847ee3776"}}