{"state_type":"pith_open_graph_state","state_version":"1.0","pith_number":"pith:2026:DBP7UKGR25PPSPTSB5FASUXUV3","merge_version":"pith-open-graph-merge-v1","event_count":2,"valid_event_count":2,"invalid_event_count":0,"equivocation_count":0,"current":{"canonical_record":{"metadata":{"abstract_canon_sha256":"ff7555b662b2d265366f9faeae92f4a2aff942a3dda54b5756fe6fcacb492236","cross_cats_sorted":[],"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-05-11T00:32:20Z","title_canon_sha256":"b9b147376af208c0102fcf3a28ad4bbffbf9dc6853eb4c036802ef7ac0206a7a"},"schema_version":"1.0","source":{"id":"2605.09835","kind":"arxiv","version":2}},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2605.09835","created_at":"2026-06-03T01:05:51Z"},{"alias_kind":"arxiv_version","alias_value":"2605.09835v2","created_at":"2026-06-03T01:05:51Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2605.09835","created_at":"2026-06-03T01:05:51Z"},{"alias_kind":"pith_short_12","alias_value":"DBP7UKGR25PP","created_at":"2026-06-03T01:05:51Z"},{"alias_kind":"pith_short_16","alias_value":"DBP7UKGR25PPSPTS","created_at":"2026-06-03T01:05:51Z"},{"alias_kind":"pith_short_8","alias_value":"DBP7UKGR","created_at":"2026-06-03T01:05:51Z"}],"graph_snapshots":[{"event_id":"sha256:9382c6e8d4e4cfa9c12174247f9cbd795241c82231c62e844b11ac78cdd4ea6b","target":"graph","created_at":"2026-06-03T01:05:51Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"graph_snapshot":{"author_claims":{"count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","strong_count":0},"builder_version":"pith-number-builder-2026-05-17-v1","claims":{"count":4,"items":[{"attestation":"unclaimed","claim_id":"C1","kind":"strongest_claim","source":"verdict.strongest_claim","status":"machine_extracted","text":"In the energy range of 57-2800 keV, the average γ-ray flux is measured to be (0.46 ± 0.06_stat ± 0.03_syst) cm^{-2} s^{-1}. A clear correlation is observed between the environmental γ-ray rate and the ambient radon concentration, consistent with the short-lived daughters of 222Rn."},{"attestation":"unclaimed","claim_id":"C2","kind":"weakest_assumption","source":"verdict.weakest_assumption","status":"machine_extracted","text":"The Geant4 simulations correctly model the full-energy-peak efficiencies and detector response for the actual environmental gamma spectrum at all eight locations; any mismatch would directly scale the reported flux."},{"attestation":"unclaimed","claim_id":"C3","kind":"one_line_summary","source":"verdict.one_line_summary","status":"machine_extracted","text":"The average environmental gamma-ray flux in Hall C at LNGS is 0.46 cm^{-2} s^{-1} (57-2800 keV) and correlates with ambient radon concentration."},{"attestation":"unclaimed","claim_id":"C4","kind":"headline","source":"verdict.pith_extraction.headline","status":"machine_extracted","text":"Environmental gamma-ray flux in Hall C at LNGS averages 0.46 cm^{-2} s^{-1} between 57 and 2800 keV and correlates directly with radon levels."}],"snapshot_sha256":"eedc7d9b6057e10610f26e1d26d3e953f0bc8768a1aef83f829912b7a3128b6b"},"formal_canon":{"evidence_count":2,"snapshot_sha256":"d545ff408e8ea2cdc2329906bde00da5d4802dbf6ac8a19d74e9de1aab3b9410"},"integrity":{"available":true,"clean":true,"detectors_run":[{"findings_count":0,"name":"claim_evidence","ran_at":"2026-05-20T07:02:01.353621Z","status":"completed","version":"1.0.0"},{"findings_count":0,"name":"ai_meta_artifact","ran_at":"2026-05-19T16:35:05.868485Z","status":"completed","version":"1.0.0"},{"findings_count":0,"name":"doi_title_agreement","ran_at":"2026-05-19T12:31:17.577911Z","status":"completed","version":"1.0.0"},{"findings_count":0,"name":"doi_compliance","ran_at":"2026-05-19T09:53:23.769772Z","status":"completed","version":"1.0.0"}],"endpoint":"/pith/2605.09835/integrity.json","findings":[],"snapshot_sha256":"8bdfdb88c2363bc7a51f7f6ba450af2030739e932c25f08b11603af3fb8b3506","summary":{"advisory":0,"by_detector":{},"critical":0,"informational":0}},"paper":{"abstract_excerpt":"We report a comprehensive measurement of the environmental $\\gamma$-ray flux in Hall C of the Gran Sasso National Laboratory. A spatial mapping of the radiation was carried out using a high-purity germanium detector mounted on a movable cart and deployed at eight locations within the hall. The detector response function and full-energy-peak efficiencies were determined through Geant4 simulations validated with calibrated $\\gamma$-ray sources, with particular attention devoted to the efficiency modeling and associated systematic uncertainties. In the energy range of 57-2800 keV, the average $\\g","authors_text":"C. Ghiano, D. Cano-Ott, G. Vera D\\'iaz, G. Zuzel, J. Plaza del Olmo, L. Luzzi, M. Laubenstein, P. Agnes, R. Santorelli, T. Mroz, V. Pesudo Fortes","cross_cats":[],"headline":"Environmental gamma-ray flux in Hall C at LNGS averages 0.46 cm^{-2} s^{-1} between 57 and 2800 keV and correlates directly with radon levels.","license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-05-11T00:32:20Z","title":"Environmental $\\gamma$-Ray Flux in Hall C at LNGS and Its Correlation with Radon Activity"},"references":{"count":0,"internal_anchors":0,"resolved_work":0,"sample":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"2605.09835","kind":"arxiv","version":2},"verdict":{"created_at":"2026-05-12T04:12:41.194921Z","id":"b514f1af-acb4-482c-a0b4-21c2e2d00c64","model_set":{"reader":"grok-4.3"},"one_line_summary":"The average environmental gamma-ray flux in Hall C at LNGS is 0.46 cm^{-2} s^{-1} (57-2800 keV) and correlates with ambient radon concentration.","pipeline_version":"pith-pipeline@v0.9.0","pith_extraction_headline":"Environmental gamma-ray flux in Hall C at LNGS averages 0.46 cm^{-2} s^{-1} between 57 and 2800 keV and correlates directly with radon levels.","strongest_claim":"In the energy range of 57-2800 keV, the average γ-ray flux is measured to be (0.46 ± 0.06_stat ± 0.03_syst) cm^{-2} s^{-1}. A clear correlation is observed between the environmental γ-ray rate and the ambient radon concentration, consistent with the short-lived daughters of 222Rn.","weakest_assumption":"The Geant4 simulations correctly model the full-energy-peak efficiencies and detector response for the actual environmental gamma spectrum at all eight locations; any mismatch would directly scale the reported flux."}},"verdict_id":"b514f1af-acb4-482c-a0b4-21c2e2d00c64"}}],"author_attestations":[],"timestamp_anchors":[],"storage_attestations":[],"citation_signatures":[],"replication_records":[],"corrections":[],"mirror_hints":[],"record_created":{"event_id":"sha256:bcf23ec259a0475e523c8699496359ea8e9eceebce740fd7dfda63a1172e2fa2","target":"record","created_at":"2026-06-03T01:05:51Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"attestation_state":"computed","canonical_record":{"metadata":{"abstract_canon_sha256":"ff7555b662b2d265366f9faeae92f4a2aff942a3dda54b5756fe6fcacb492236","cross_cats_sorted":[],"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"physics.ins-det","submitted_at":"2026-05-11T00:32:20Z","title_canon_sha256":"b9b147376af208c0102fcf3a28ad4bbffbf9dc6853eb4c036802ef7ac0206a7a"},"schema_version":"1.0","source":{"id":"2605.09835","kind":"arxiv","version":2}},"canonical_sha256":"185ffa28d1d75ef93e720f4a0952f4aeeb0055c700e5bbd06ab0d1608719406d","receipt":{"algorithm":"ed25519","builder_version":"pith-number-builder-2026-05-17-v1","canonical_sha256":"185ffa28d1d75ef93e720f4a0952f4aeeb0055c700e5bbd06ab0d1608719406d","first_computed_at":"2026-06-03T01:05:51.234018Z","key_id":"pith-v1-2026-05","kind":"pith_receipt","last_reissued_at":"2026-06-03T01:05:51.234018Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","receipt_version":"0.3","signature_b64":"D0UpMI0tkJjX48RCJHaSB018W5NUNvdxY9PHHfFALTdZc7411uesizKGYGc2XyKwe64VLEItGlRTRsQq3OgiDw==","signature_status":"signed_v1","signed_at":"2026-06-03T01:05:51.234513Z","signed_message":"canonical_sha256_bytes"},"source_id":"2605.09835","source_kind":"arxiv","source_version":2}}},"equivocations":[],"invalid_events":[],"applied_event_ids":["sha256:bcf23ec259a0475e523c8699496359ea8e9eceebce740fd7dfda63a1172e2fa2","sha256:9382c6e8d4e4cfa9c12174247f9cbd795241c82231c62e844b11ac78cdd4ea6b"],"state_sha256":"66ef8a46a51347f66974eedf0f433150ead7a5ebfa31e564aab13c6e41caad4d"}