{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2026:DRYU3WOKK5CDDUNEIXCE5K6GWQ","short_pith_number":"pith:DRYU3WOK","schema_version":"1.0","canonical_sha256":"1c714dd9ca574431d1a445c44eabc6b42dc69b4c9a1ee9678d63c175f071783f","source":{"kind":"arxiv","id":"2605.13061","version":1},"attestation_state":"computed","paper":{"title":"Revisiting Voltage and Synchronization Stability Analysis in Converter-Integrated Weak Grids: Insights from Non-Minimum-Phase Zeros","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","headline":"Non-minimum phase zeros in the grid Jacobian transfer matrix cause both voltage instability and synchronization issues in weak grids with converter-interfaced generators.","cross_cats":["cs.SY"],"primary_cat":"eess.SY","authors_text":"Fuyilong Ma, Huanhai Xin, Lennart Harnefors, Lidong Zhang, Linbin Huang, Waisheng Zheng, Wangqianyun Tang","submitted_at":"2026-05-13T06:33:42Z","abstract_excerpt":"The increasing penetration of converter-interfaced generators (CIGs) intensifies concerns over small-signal voltage and synchronization stability. While existing theories treat these two stability issues distinctly, practical wisdom in contrast employs a unified and static metric, short-circuit ratio (SCR), to assess both in weak grids. This paper aims to bridge this theory-practice gap by introducing the insight of non-minimum phase (NMP) zeros. First, we demonstrate that the two stability issues in weak grids originate from NMP zeros in the grid Jacobian transfer matrix: a zero at the origin"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":true,"formal_links_present":true},"canonical_record":{"source":{"id":"2605.13061","kind":"arxiv","version":1},"metadata":{"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"eess.SY","submitted_at":"2026-05-13T06:33:42Z","cross_cats_sorted":["cs.SY"],"title_canon_sha256":"b6ae4ac11a8c848d0b60d484b047af0ef5f3c666c0cb4ef7c1315c28550fed16","abstract_canon_sha256":"9023d4f9fa8ce0b00521e3d749cbc6706d1195840ca7a9a7345c75488d74b13c"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-05-18T03:08:59.101565Z","signature_b64":"jQMPoWzF5LVZu31VzEpMg3B3ZkTmK5ZT8Xj5r3azHIFO2d4Tk2sw4c7Tg3XZC2u+cujcQ8JESf94Eski6aoCCw==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"1c714dd9ca574431d1a445c44eabc6b42dc69b4c9a1ee9678d63c175f071783f","last_reissued_at":"2026-05-18T03:08:59.101047Z","signature_status":"signed_v1","first_computed_at":"2026-05-18T03:08:59.101047Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"Revisiting Voltage and Synchronization Stability Analysis in Converter-Integrated Weak Grids: Insights from Non-Minimum-Phase Zeros","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","headline":"Non-minimum phase zeros in the grid Jacobian transfer matrix cause both voltage instability and synchronization issues in weak grids with converter-interfaced generators.","cross_cats":["cs.SY"],"primary_cat":"eess.SY","authors_text":"Fuyilong Ma, Huanhai Xin, Lennart Harnefors, Lidong Zhang, Linbin Huang, Waisheng Zheng, Wangqianyun Tang","submitted_at":"2026-05-13T06:33:42Z","abstract_excerpt":"The increasing penetration of converter-interfaced generators (CIGs) intensifies concerns over small-signal voltage and synchronization stability. While existing theories treat these two stability issues distinctly, practical wisdom in contrast employs a unified and static metric, short-circuit ratio (SCR), to assess both in weak grids. This paper aims to bridge this theory-practice gap by introducing the insight of non-minimum phase (NMP) zeros. First, we demonstrate that the two stability issues in weak grids originate from NMP zeros in the grid Jacobian transfer matrix: a zero at the origin"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"We demonstrate that the two stability issues in weak grids originate from NMP zeros in the grid Jacobian transfer matrix: a zero at the origin corresponds to voltage instability, while low-frequency zeros impose fundamental constraints on synchronization dynamics. The traditional SCR is proven to be a special case of our proposed novel stability metric, NMP-zero (NMP-Z) factor, evaluated at the rated operating point.","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"The analysis relies on small-signal linearization of the system around an operating point and the assumption that the grid Jacobian transfer matrix fully captures the relevant dynamics for both voltage and synchronization stability.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"Non-minimum-phase zeros in the grid Jacobian explain both voltage and synchronization instability in weak grids, with the short-circuit ratio as a special case of the proposed NMP-Z factor at rated operating point.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"Non-minimum phase zeros in the grid Jacobian transfer matrix cause both voltage instability and synchronization issues in weak grids with converter-interfaced generators.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"4982e569703968a61e12e867432c76b9fa82ac6f07cddc5b688e54ff2dc7b4ff"},"source":{"id":"2605.13061","kind":"arxiv","version":1},"verdict":{"id":"05bf8d23-7e75-45e1-9049-5363b50e7f3f","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-14T19:01:49.579702Z","strongest_claim":"We demonstrate that the two stability issues in weak grids originate from NMP zeros in the grid Jacobian transfer matrix: a zero at the origin corresponds to voltage instability, while low-frequency zeros impose fundamental constraints on synchronization dynamics. The traditional SCR is proven to be a special case of our proposed novel stability metric, NMP-zero (NMP-Z) factor, evaluated at the rated operating point.","one_line_summary":"Non-minimum-phase zeros in the grid Jacobian explain both voltage and synchronization instability in weak grids, with the short-circuit ratio as a special case of the proposed NMP-Z factor at rated operating point.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"The analysis relies on small-signal linearization of the system around an operating point and the assumption that the grid Jacobian transfer matrix fully captures the relevant dynamics for both voltage and synchronization stability.","pith_extraction_headline":"Non-minimum phase zeros in the grid Jacobian transfer matrix cause both voltage instability and synchronization issues in weak grids with converter-interfaced generators."},"references":{"count":27,"sample":[{"doi":"","year":2022,"title":"Power system stability with a high penetration of inverter-based resources","work_id":"59bfb504-9f29-4014-ad22-ff9c489bae94","ref_index":1,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2021,"title":"Definition and Classification of Power System Stability – Revisited & Extended,","work_id":"d9a3a638-7f58-459b-838b-d65d6c7cdbe0","ref_index":2,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2020,"title":"Small-Disturbance V oltage Stability of Power Systems: Dependence on Network Structure,","work_id":"98b1c71b-6da7-42bb-a6bb-287cab57d7c9","ref_index":3,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2022,"title":"Real-world subsynchronous oscillation events in power grids with high penetrations of inverter-based resources,","work_id":"08beef4d-a64e-495b-a6a7-e06fbea03d64","ref_index":4,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2020,"title":"Grid-synchronization stability of converter-based resources—an overview,","work_id":"b0965963-b2c8-4b28-b877-363165041a54","ref_index":5,"cited_arxiv_id":"","is_internal_anchor":false}],"resolved_work":27,"snapshot_sha256":"af46a8b2f00867a90ea5e301f56f1cab5431385ed3a686f5be809a43bb6ffe0e","internal_anchors":0},"formal_canon":{"evidence_count":2,"snapshot_sha256":"47fd2141eebe98944c98158f3740681c3eec07afba243bf989d858c9bc8b8c23"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"2605.13061","created_at":"2026-05-18T03:08:59.101126+00:00"},{"alias_kind":"arxiv_version","alias_value":"2605.13061v1","created_at":"2026-05-18T03:08:59.101126+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2605.13061","created_at":"2026-05-18T03:08:59.101126+00:00"},{"alias_kind":"pith_short_12","alias_value":"DRYU3WOKK5CD","created_at":"2026-05-18T12:33:37.589309+00:00"},{"alias_kind":"pith_short_16","alias_value":"DRYU3WOKK5CDDUNE","created_at":"2026-05-18T12:33:37.589309+00:00"},{"alias_kind":"pith_short_8","alias_value":"DRYU3WOK","created_at":"2026-05-18T12:33:37.589309+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":0,"internal_anchor_count":0,"sample":[]},"formal_canon":{"evidence_count":2,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ","json":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ.json","graph_json":"https://pith.science/api/pith-number/DRYU3WOKK5CDDUNEIXCE5K6GWQ/graph.json","events_json":"https://pith.science/api/pith-number/DRYU3WOKK5CDDUNEIXCE5K6GWQ/events.json","paper":"https://pith.science/paper/DRYU3WOK"},"agent_actions":{"view_html":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ","download_json":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ.json","view_paper":"https://pith.science/paper/DRYU3WOK","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=2605.13061&json=true","fetch_graph":"https://pith.science/api/pith-number/DRYU3WOKK5CDDUNEIXCE5K6GWQ/graph.json","fetch_events":"https://pith.science/api/pith-number/DRYU3WOKK5CDDUNEIXCE5K6GWQ/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ/action/timestamp_anchor","attest_storage":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ/action/storage_attestation","attest_author":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ/action/author_attestation","sign_citation":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ/action/citation_signature","submit_replication":"https://pith.science/pith/DRYU3WOKK5CDDUNEIXCE5K6GWQ/action/replication_record"}},"created_at":"2026-05-18T03:08:59.101126+00:00","updated_at":"2026-05-18T03:08:59.101126+00:00"}