{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2025:E7OSGCEMPQ4LZ6WZ22KURJIZJG","short_pith_number":"pith:E7OSGCEM","schema_version":"1.0","canonical_sha256":"27dd23088c7c38bcfad9d69548a519498cc52f13a6686022499af9abfc47b834","source":{"kind":"arxiv","id":"2502.14607","version":1},"attestation_state":"computed","paper":{"title":"A Millimeter-Wave Photometric Camera for Long-Range Imaging Through Optical Obscurants Using Kinetic Inductance Detectors","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"","cross_cats":[],"primary_cat":"astro-ph.IM","authors_text":"Adhitya B. Sriram, Bradley R. Johnson, Byeong Ho Eom, Cody Roberson, Daniel Cunnane, Eric Weeks, Fabien Defrance, Henry G. Leduc, Jack Sayers, Jonathan Greenfield, Liam C. Walters, Marcus C. Runyan, Matthew Hollister, Nia McNichols, Peter K. Day, Philip Mauskopf, Ryan C. Stephenson, Sage Crystian, Sage Stanton","submitted_at":"2025-02-20T14:45:55Z","abstract_excerpt":"Passive imaging through optical obscurants is a promising application for mm-wave sensing. We have thus developed the Superconducting Kinetic Inductance Passive Radiometer (SKIPR), a 150 GHz polarization-sensitive photometric camera optimized for terrestrial imaging using a focal plane array with 3,840 kinetic inductance detectors (KIDs). We present a full description of the instrument design, with a particular emphasis on the cryogenic system based on a Gifford-McMahon cryocooler with a two-stage Adiabatic Demagnetization Refrigerator and a dedicated 1.59 m crossed Dragone telescope with an a"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":false,"formal_links_present":false},"canonical_record":{"source":{"id":"2502.14607","kind":"arxiv","version":1},"metadata":{"license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"astro-ph.IM","submitted_at":"2025-02-20T14:45:55Z","cross_cats_sorted":[],"title_canon_sha256":"fca0d20274d07df5a604f8757f8ee810c0f571d71730c741b618839a7e577b6d","abstract_canon_sha256":"ab639654aaf1e1ecb5f8b91455eb2302371dbb70605ba3bf8042b197906c6b84"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-07-05T10:17:29.908556Z","signature_b64":"Mtj27FLKmC5P1n26S1OYEJTK7DpDzITRqvyhgVu0PiwKuJsI+xkfFgwFmWJEq8rf08W7Cv0GkAzBshXEybZrBQ==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"27dd23088c7c38bcfad9d69548a519498cc52f13a6686022499af9abfc47b834","last_reissued_at":"2026-07-05T10:17:29.907996Z","signature_status":"signed_v1","first_computed_at":"2026-07-05T10:17:29.907996Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"A Millimeter-Wave Photometric Camera for Long-Range Imaging Through Optical Obscurants Using Kinetic Inductance Detectors","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"","cross_cats":[],"primary_cat":"astro-ph.IM","authors_text":"Adhitya B. Sriram, Bradley R. Johnson, Byeong Ho Eom, Cody Roberson, Daniel Cunnane, Eric Weeks, Fabien Defrance, Henry G. Leduc, Jack Sayers, Jonathan Greenfield, Liam C. Walters, Marcus C. Runyan, Matthew Hollister, Nia McNichols, Peter K. Day, Philip Mauskopf, Ryan C. Stephenson, Sage Crystian, Sage Stanton","submitted_at":"2025-02-20T14:45:55Z","abstract_excerpt":"Passive imaging through optical obscurants is a promising application for mm-wave sensing. We have thus developed the Superconducting Kinetic Inductance Passive Radiometer (SKIPR), a 150 GHz polarization-sensitive photometric camera optimized for terrestrial imaging using a focal plane array with 3,840 kinetic inductance detectors (KIDs). We present a full description of the instrument design, with a particular emphasis on the cryogenic system based on a Gifford-McMahon cryocooler with a two-stage Adiabatic Demagnetization Refrigerator and a dedicated 1.59 m crossed Dragone telescope with an a"},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"2502.14607","kind":"arxiv","version":1},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/2502.14607/integrity.json","findings":[],"available":true,"detectors_run":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938"},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"2502.14607","created_at":"2026-07-05T10:17:29.908057+00:00"},{"alias_kind":"arxiv_version","alias_value":"2502.14607v1","created_at":"2026-07-05T10:17:29.908057+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2502.14607","created_at":"2026-07-05T10:17:29.908057+00:00"},{"alias_kind":"pith_short_12","alias_value":"E7OSGCEMPQ4L","created_at":"2026-07-05T10:17:29.908057+00:00"},{"alias_kind":"pith_short_16","alias_value":"E7OSGCEMPQ4LZ6WZ","created_at":"2026-07-05T10:17:29.908057+00:00"},{"alias_kind":"pith_short_8","alias_value":"E7OSGCEM","created_at":"2026-07-05T10:17:29.908057+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":1,"internal_anchor_count":1,"sample":[{"citing_arxiv_id":"2608.02860","citing_title":"An Open Source RFSoC-based Readout Electronics System for Arrays of Kinetic Inductance Detectors and Superconducting Resonators","ref_index":16,"is_internal_anchor":true}]},"formal_canon":{"evidence_count":0,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG","json":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG.json","graph_json":"https://pith.science/api/pith-number/E7OSGCEMPQ4LZ6WZ22KURJIZJG/graph.json","events_json":"https://pith.science/api/pith-number/E7OSGCEMPQ4LZ6WZ22KURJIZJG/events.json","paper":"https://pith.science/paper/E7OSGCEM"},"agent_actions":{"view_html":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG","download_json":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG.json","view_paper":"https://pith.science/paper/E7OSGCEM","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=2502.14607&json=true","fetch_graph":"https://pith.science/api/pith-number/E7OSGCEMPQ4LZ6WZ22KURJIZJG/graph.json","fetch_events":"https://pith.science/api/pith-number/E7OSGCEMPQ4LZ6WZ22KURJIZJG/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG/action/timestamp_anchor","attest_storage":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG/action/storage_attestation","attest_author":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG/action/author_attestation","sign_citation":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG/action/citation_signature","submit_replication":"https://pith.science/pith/E7OSGCEMPQ4LZ6WZ22KURJIZJG/action/replication_record"}},"created_at":"2026-07-05T10:17:29.908057+00:00","updated_at":"2026-07-05T10:17:29.908057+00:00"}