{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2025:GNVDWHA24OCEQICEDQ62WRYKBX","short_pith_number":"pith:GNVDWHA2","schema_version":"1.0","canonical_sha256":"336a3b1c1ae3844820441c3dab470a0de94dbb467e8dd6886681e17d2210315b","source":{"kind":"arxiv","id":"2512.23974","version":3},"attestation_state":"computed","paper":{"title":"Design, construction, and testing of the PandaX-xT cryogenics system","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"The PandaX-xT cryogenics system with two cooling towers delivers about 1900 W at 178 K and keeps xenon pressure stable within 1 kPa for a month in a one-tonne prototype.","cross_cats":[],"primary_cat":"physics.ins-det","authors_text":"Jianglai Liu, Li Zhao, Shuaijie Li, Xiang Xiao, Xiangyi Cui, Xu Wang","submitted_at":"2025-12-30T04:07:26Z","abstract_excerpt":"The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of liquid xenon. A new cryogenics system of the PandaX-xT is described in this paper. It is developed to handle large mass of liquid xenon efficiently and safely, including two cooling towers for normal operation and one liquid-nitrogen coil for emergency case. Each cooling tower equipped with an AL600 Gifford-McMahon cryocooler features a 1300 W heater, specifi"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":false,"formal_links_present":false},"canonical_record":{"source":{"id":"2512.23974","kind":"arxiv","version":3},"metadata":{"license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"physics.ins-det","submitted_at":"2025-12-30T04:07:26Z","cross_cats_sorted":[],"title_canon_sha256":"700ecab434decb067497c963640b83a02b52abb588ba51586115f02501eea4e8","abstract_canon_sha256":"62b651cf722b581be53434b6e67bcfb2bbb06a2fda96524e10afdc3f5049289c"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-06-02T02:04:12.753674Z","signature_b64":"V7WawiQaf2WUNVXyy2Lhhr2WetxmCwEdq+ev5IpyAFPGwFMqcGaR0jubOJbxLbXb0vK/aZW617Q/rxtiNjduCA==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"336a3b1c1ae3844820441c3dab470a0de94dbb467e8dd6886681e17d2210315b","last_reissued_at":"2026-06-02T02:04:12.753137Z","signature_status":"signed_v1","first_computed_at":"2026-06-02T02:04:12.753137Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"Design, construction, and testing of the PandaX-xT cryogenics system","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"The PandaX-xT cryogenics system with two cooling towers delivers about 1900 W at 178 K and keeps xenon pressure stable within 1 kPa for a month in a one-tonne prototype.","cross_cats":[],"primary_cat":"physics.ins-det","authors_text":"Jianglai Liu, Li Zhao, Shuaijie Li, Xiang Xiao, Xiangyi Cui, Xu Wang","submitted_at":"2025-12-30T04:07:26Z","abstract_excerpt":"The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of liquid xenon. A new cryogenics system of the PandaX-xT is described in this paper. It is developed to handle large mass of liquid xenon efficiently and safely, including two cooling towers for normal operation and one liquid-nitrogen coil for emergency case. Each cooling tower equipped with an AL600 Gifford-McMahon cryocooler features a 1300 W heater, specifi"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"The cryogenics system with two cooling towers has achieved about 1900 W cooling power at 178 K. The liquid nitrogen coil provides emergency cooling power of more than 1500 W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210 kPa.","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"The performance measured on the 1-tonne prototype and individual cooling towers will scale without major thermal losses, leaks, or safety issues to the full 43-tonne detector volume.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"The PandaX-xT cryogenics system with two cooling towers delivers 1900 W cooling power at 178 K, the liquid-nitrogen coil supplies over 1500 W emergency cooling, and a 1-tonne prototype maintains xenon vapor pressure stable within 1 kPa for one month.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"The PandaX-xT cryogenics system with two cooling towers delivers about 1900 W at 178 K and keeps xenon pressure stable within 1 kPa for a month in a one-tonne prototype.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"a2e29ae16351437aedb145049d3e0cfeea9111f6170ee89eacadc6c37cd5bc37"},"source":{"id":"2512.23974","kind":"arxiv","version":3},"verdict":{"id":"1fc90c96-7644-47b5-8d8f-a4082c555615","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-16T19:44:40.831158Z","strongest_claim":"The cryogenics system with two cooling towers has achieved about 1900 W cooling power at 178 K. The liquid nitrogen coil provides emergency cooling power of more than 1500 W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210 kPa.","one_line_summary":"The PandaX-xT cryogenics system with two cooling towers delivers 1900 W cooling power at 178 K, the liquid-nitrogen coil supplies over 1500 W emergency cooling, and a 1-tonne prototype maintains xenon vapor pressure stable within 1 kPa for one month.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"The performance measured on the 1-tonne prototype and individual cooling towers will scale without major thermal losses, leaks, or safety issues to the full 43-tonne detector volume.","pith_extraction_headline":"The PandaX-xT cryogenics system with two cooling towers delivers about 1900 W at 178 K and keeps xenon pressure stable within 1 kPa for a month in a one-tonne prototype."},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/2512.23974/integrity.json","findings":[],"available":true,"detectors_run":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938"},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"2512.23974","created_at":"2026-06-02T02:04:12.753203+00:00"},{"alias_kind":"arxiv_version","alias_value":"2512.23974v3","created_at":"2026-06-02T02:04:12.753203+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2512.23974","created_at":"2026-06-02T02:04:12.753203+00:00"},{"alias_kind":"pith_short_12","alias_value":"GNVDWHA24OCE","created_at":"2026-06-02T02:04:12.753203+00:00"},{"alias_kind":"pith_short_16","alias_value":"GNVDWHA24OCEQICE","created_at":"2026-06-02T02:04:12.753203+00:00"},{"alias_kind":"pith_short_8","alias_value":"GNVDWHA2","created_at":"2026-06-02T02:04:12.753203+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":0,"internal_anchor_count":0,"sample":[]},"formal_canon":{"evidence_count":0,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX","json":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX.json","graph_json":"https://pith.science/api/pith-number/GNVDWHA24OCEQICEDQ62WRYKBX/graph.json","events_json":"https://pith.science/api/pith-number/GNVDWHA24OCEQICEDQ62WRYKBX/events.json","paper":"https://pith.science/paper/GNVDWHA2"},"agent_actions":{"view_html":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX","download_json":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX.json","view_paper":"https://pith.science/paper/GNVDWHA2","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=2512.23974&json=true","fetch_graph":"https://pith.science/api/pith-number/GNVDWHA24OCEQICEDQ62WRYKBX/graph.json","fetch_events":"https://pith.science/api/pith-number/GNVDWHA24OCEQICEDQ62WRYKBX/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX/action/timestamp_anchor","attest_storage":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX/action/storage_attestation","attest_author":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX/action/author_attestation","sign_citation":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX/action/citation_signature","submit_replication":"https://pith.science/pith/GNVDWHA24OCEQICEDQ62WRYKBX/action/replication_record"}},"created_at":"2026-06-02T02:04:12.753203+00:00","updated_at":"2026-06-02T02:04:12.753203+00:00"}