{"state_type":"pith_open_graph_state","state_version":"1.0","pith_number":"pith:2025:GNVDWHA24OCEQICEDQ62WRYKBX","merge_version":"pith-open-graph-merge-v1","event_count":2,"valid_event_count":2,"invalid_event_count":0,"equivocation_count":0,"current":{"canonical_record":{"metadata":{"abstract_canon_sha256":"62b651cf722b581be53434b6e67bcfb2bbb06a2fda96524e10afdc3f5049289c","cross_cats_sorted":[],"license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"physics.ins-det","submitted_at":"2025-12-30T04:07:26Z","title_canon_sha256":"700ecab434decb067497c963640b83a02b52abb588ba51586115f02501eea4e8"},"schema_version":"1.0","source":{"id":"2512.23974","kind":"arxiv","version":3}},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2512.23974","created_at":"2026-06-02T02:04:12Z"},{"alias_kind":"arxiv_version","alias_value":"2512.23974v3","created_at":"2026-06-02T02:04:12Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2512.23974","created_at":"2026-06-02T02:04:12Z"},{"alias_kind":"pith_short_12","alias_value":"GNVDWHA24OCE","created_at":"2026-06-02T02:04:12Z"},{"alias_kind":"pith_short_16","alias_value":"GNVDWHA24OCEQICE","created_at":"2026-06-02T02:04:12Z"},{"alias_kind":"pith_short_8","alias_value":"GNVDWHA2","created_at":"2026-06-02T02:04:12Z"}],"graph_snapshots":[{"event_id":"sha256:eb71ec3cc0b30889a5565fdc668a43d0fdcbdaf7afc6318bcc6e5a7c08ed8997","target":"graph","created_at":"2026-06-02T02:04:12Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"graph_snapshot":{"author_claims":{"count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","strong_count":0},"builder_version":"pith-number-builder-2026-05-17-v1","claims":{"count":4,"items":[{"attestation":"unclaimed","claim_id":"C1","kind":"strongest_claim","source":"verdict.strongest_claim","status":"machine_extracted","text":"The cryogenics system with two cooling towers has achieved about 1900 W cooling power at 178 K. The liquid nitrogen coil provides emergency cooling power of more than 1500 W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210 kPa."},{"attestation":"unclaimed","claim_id":"C2","kind":"weakest_assumption","source":"verdict.weakest_assumption","status":"machine_extracted","text":"The performance measured on the 1-tonne prototype and individual cooling towers will scale without major thermal losses, leaks, or safety issues to the full 43-tonne detector volume."},{"attestation":"unclaimed","claim_id":"C3","kind":"one_line_summary","source":"verdict.one_line_summary","status":"machine_extracted","text":"The PandaX-xT cryogenics system with two cooling towers delivers 1900 W cooling power at 178 K, the liquid-nitrogen coil supplies over 1500 W emergency cooling, and a 1-tonne prototype maintains xenon vapor pressure stable within 1 kPa for one month."},{"attestation":"unclaimed","claim_id":"C4","kind":"headline","source":"verdict.pith_extraction.headline","status":"machine_extracted","text":"The PandaX-xT cryogenics system with two cooling towers delivers about 1900 W at 178 K and keeps xenon pressure stable within 1 kPa for a month in a one-tonne prototype."}],"snapshot_sha256":"a2e29ae16351437aedb145049d3e0cfeea9111f6170ee89eacadc6c37cd5bc37"},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"integrity":{"available":true,"clean":true,"detectors_run":[],"endpoint":"/pith/2512.23974/integrity.json","findings":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938","summary":{"advisory":0,"by_detector":{},"critical":0,"informational":0}},"paper":{"abstract_excerpt":"The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of liquid xenon. A new cryogenics system of the PandaX-xT is described in this paper. It is developed to handle large mass of liquid xenon efficiently and safely, including two cooling towers for normal operation and one liquid-nitrogen coil for emergency case. Each cooling tower equipped with an AL600 Gifford-McMahon cryocooler features a 1300 W heater, specifi","authors_text":"Jianglai Liu, Li Zhao, Shuaijie Li, Xiang Xiao, Xiangyi Cui, Xu Wang","cross_cats":[],"headline":"The PandaX-xT cryogenics system with two cooling towers delivers about 1900 W at 178 K and keeps xenon pressure stable within 1 kPa for a month in a one-tonne prototype.","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"physics.ins-det","submitted_at":"2025-12-30T04:07:26Z","title":"Design, construction, and testing of the PandaX-xT cryogenics system"},"references":{"count":0,"internal_anchors":0,"resolved_work":0,"sample":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"2512.23974","kind":"arxiv","version":3},"verdict":{"created_at":"2026-05-16T19:44:40.831158Z","id":"1fc90c96-7644-47b5-8d8f-a4082c555615","model_set":{"reader":"grok-4.3"},"one_line_summary":"The PandaX-xT cryogenics system with two cooling towers delivers 1900 W cooling power at 178 K, the liquid-nitrogen coil supplies over 1500 W emergency cooling, and a 1-tonne prototype maintains xenon vapor pressure stable within 1 kPa for one month.","pipeline_version":"pith-pipeline@v0.9.0","pith_extraction_headline":"The PandaX-xT cryogenics system with two cooling towers delivers about 1900 W at 178 K and keeps xenon pressure stable within 1 kPa for a month in a one-tonne prototype.","strongest_claim":"The cryogenics system with two cooling towers has achieved about 1900 W cooling power at 178 K. The liquid nitrogen coil provides emergency cooling power of more than 1500 W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210 kPa.","weakest_assumption":"The performance measured on the 1-tonne prototype and individual cooling towers will scale without major thermal losses, leaks, or safety issues to the full 43-tonne detector volume."}},"verdict_id":"1fc90c96-7644-47b5-8d8f-a4082c555615"}}],"author_attestations":[],"timestamp_anchors":[],"storage_attestations":[],"citation_signatures":[],"replication_records":[],"corrections":[],"mirror_hints":[],"record_created":{"event_id":"sha256:64041102a8df49b4d66d27822c7954bfd404f5dc412a644358f25a16fd9761f1","target":"record","created_at":"2026-06-02T02:04:12Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"attestation_state":"computed","canonical_record":{"metadata":{"abstract_canon_sha256":"62b651cf722b581be53434b6e67bcfb2bbb06a2fda96524e10afdc3f5049289c","cross_cats_sorted":[],"license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"physics.ins-det","submitted_at":"2025-12-30T04:07:26Z","title_canon_sha256":"700ecab434decb067497c963640b83a02b52abb588ba51586115f02501eea4e8"},"schema_version":"1.0","source":{"id":"2512.23974","kind":"arxiv","version":3}},"canonical_sha256":"336a3b1c1ae3844820441c3dab470a0de94dbb467e8dd6886681e17d2210315b","receipt":{"algorithm":"ed25519","builder_version":"pith-number-builder-2026-05-17-v1","canonical_sha256":"336a3b1c1ae3844820441c3dab470a0de94dbb467e8dd6886681e17d2210315b","first_computed_at":"2026-06-02T02:04:12.753137Z","key_id":"pith-v1-2026-05","kind":"pith_receipt","last_reissued_at":"2026-06-02T02:04:12.753137Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","receipt_version":"0.3","signature_b64":"V7WawiQaf2WUNVXyy2Lhhr2WetxmCwEdq+ev5IpyAFPGwFMqcGaR0jubOJbxLbXb0vK/aZW617Q/rxtiNjduCA==","signature_status":"signed_v1","signed_at":"2026-06-02T02:04:12.753674Z","signed_message":"canonical_sha256_bytes"},"source_id":"2512.23974","source_kind":"arxiv","source_version":3}}},"equivocations":[],"invalid_events":[],"applied_event_ids":["sha256:64041102a8df49b4d66d27822c7954bfd404f5dc412a644358f25a16fd9761f1","sha256:eb71ec3cc0b30889a5565fdc668a43d0fdcbdaf7afc6318bcc6e5a7c08ed8997"],"state_sha256":"c6ae61abfcd64da06b6381610ea686d76fd84f8e119ea2d7062bde865b33591d"}