{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2026:ON6S2PRUD7DYJSSNJ2N2VUFHLM","short_pith_number":"pith:ON6S2PRU","schema_version":"1.0","canonical_sha256":"737d2d3e341fc784ca4d4e9baad0a75b20ad2a432c2ea30135a837aaddfe115d","source":{"kind":"arxiv","id":"2604.21625","version":2},"attestation_state":"computed","paper":{"title":"DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"Re-extracting a subset of BSIM4 parameters from 77 K measurements produces a usable isothermal SPICE model for SkyWater 130 nm MOSFETs with roughly 20 percent average error.","cross_cats":["hep-ex"],"primary_cat":"cond-mat.mes-hall","authors_text":"A.D.McDonald, A.Rimal, D.Braga, F.Beall, I. Parmaksiz, J.Asaadi, J.B.R.Battat, O.Seidel, V.A.Chirayath, Y.Mei","submitted_at":"2026-04-23T12:45:11Z","abstract_excerpt":"Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130 nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrog"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":false,"formal_links_present":false},"canonical_record":{"source":{"id":"2604.21625","kind":"arxiv","version":2},"metadata":{"license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"cond-mat.mes-hall","submitted_at":"2026-04-23T12:45:11Z","cross_cats_sorted":["hep-ex"],"title_canon_sha256":"6c314ff8df453bce5cce64f864a9640efadfa70ed9fa40fb11db0593f3cf3ad0","abstract_canon_sha256":"fdce57392ef7790632ac46a023d0a97fb5265061e66f50ca4c5985b09ae3a30f"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-06-01T01:02:40.206616Z","signature_b64":"Ph9OHdJcJxuO964MIb58MRLdJZnOhH6jdBoP8FKs8pUBhnOQhXytnf3u69cwl0H2+rBVoqpCoNV++/boOMpdCA==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"737d2d3e341fc784ca4d4e9baad0a75b20ad2a432c2ea30135a837aaddfe115d","last_reissued_at":"2026-06-01T01:02:40.205369Z","signature_status":"signed_v1","first_computed_at":"2026-06-01T01:02:40.205369Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"Re-extracting a subset of BSIM4 parameters from 77 K measurements produces a usable isothermal SPICE model for SkyWater 130 nm MOSFETs with roughly 20 percent average error.","cross_cats":["hep-ex"],"primary_cat":"cond-mat.mes-hall","authors_text":"A.D.McDonald, A.Rimal, D.Braga, F.Beall, I. Parmaksiz, J.Asaadi, J.B.R.Battat, O.Seidel, V.A.Chirayath, Y.Mei","submitted_at":"2026-04-23T12:45:11Z","abstract_excerpt":"Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130 nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrog"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage.","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"That re-extracting a subset of BSIM4 parameters from 77 K DC data is sufficient to produce a usable isothermal model without additional temperature-dependent equations or self-heating corrections.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"An isothermal BSIM4 model for SKY130 transistors at 77 K was extracted from measurements and validated with ~20% relative RMS error independent of drain voltage.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"Re-extracting a subset of BSIM4 parameters from 77 K measurements produces a usable isothermal SPICE model for SkyWater 130 nm MOSFETs with roughly 20 percent average error.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"221eb36e26f9eb9bd75d1eefbaeae2b6a7112fce86f07c338700d4f6bbcb7948"},"source":{"id":"2604.21625","kind":"arxiv","version":2},"verdict":{"id":"364ab6c8-0ff7-4d99-9d0c-0163e1813bf7","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-09T21:00:37.441799Z","strongest_claim":"We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage.","one_line_summary":"An isothermal BSIM4 model for SKY130 transistors at 77 K was extracted from measurements and validated with ~20% relative RMS error independent of drain voltage.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"That re-extracting a subset of BSIM4 parameters from 77 K DC data is sufficient to produce a usable isothermal model without additional temperature-dependent equations or self-heating corrections.","pith_extraction_headline":"Re-extracting a subset of BSIM4 parameters from 77 K measurements produces a usable isothermal SPICE model for SkyWater 130 nm MOSFETs with roughly 20 percent average error."},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/2604.21625/integrity.json","findings":[],"available":true,"detectors_run":[{"name":"ai_meta_artifact","ran_at":"2026-05-21T12:37:20.897631Z","status":"completed","version":"1.0.0","findings_count":0},{"name":"doi_compliance","ran_at":"2026-05-20T00:48:06.794931Z","status":"completed","version":"1.0.0","findings_count":0}],"snapshot_sha256":"1f3e82129b1f29da0cfd11e1078777604c1ff5dbca6781b472bf640546101aaf"},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"2604.21625","created_at":"2026-06-01T01:02:40.205489+00:00"},{"alias_kind":"arxiv_version","alias_value":"2604.21625v2","created_at":"2026-06-01T01:02:40.205489+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2604.21625","created_at":"2026-06-01T01:02:40.205489+00:00"},{"alias_kind":"pith_short_12","alias_value":"ON6S2PRUD7DY","created_at":"2026-06-01T01:02:40.205489+00:00"},{"alias_kind":"pith_short_16","alias_value":"ON6S2PRUD7DYJSSN","created_at":"2026-06-01T01:02:40.205489+00:00"},{"alias_kind":"pith_short_8","alias_value":"ON6S2PRU","created_at":"2026-06-01T01:02:40.205489+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":0,"internal_anchor_count":0,"sample":[]},"formal_canon":{"evidence_count":0,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM","json":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM.json","graph_json":"https://pith.science/api/pith-number/ON6S2PRUD7DYJSSNJ2N2VUFHLM/graph.json","events_json":"https://pith.science/api/pith-number/ON6S2PRUD7DYJSSNJ2N2VUFHLM/events.json","paper":"https://pith.science/paper/ON6S2PRU"},"agent_actions":{"view_html":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM","download_json":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM.json","view_paper":"https://pith.science/paper/ON6S2PRU","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=2604.21625&json=true","fetch_graph":"https://pith.science/api/pith-number/ON6S2PRUD7DYJSSNJ2N2VUFHLM/graph.json","fetch_events":"https://pith.science/api/pith-number/ON6S2PRUD7DYJSSNJ2N2VUFHLM/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM/action/timestamp_anchor","attest_storage":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM/action/storage_attestation","attest_author":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM/action/author_attestation","sign_citation":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM/action/citation_signature","submit_replication":"https://pith.science/pith/ON6S2PRUD7DYJSSNJ2N2VUFHLM/action/replication_record"}},"created_at":"2026-06-01T01:02:40.205489+00:00","updated_at":"2026-06-01T01:02:40.205489+00:00"}