{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2026:PAWGWSC2SQHHEDT3VLS2E4OU6T","short_pith_number":"pith:PAWGWSC2","schema_version":"1.0","canonical_sha256":"782c6b485a940e720e7baae5a271d4f4db6e148a43dab515ba6657935532a14b","source":{"kind":"arxiv","id":"2605.14109","version":1},"attestation_state":"computed","paper":{"title":"Grid Integration of Gigawatt-Scale AI Data Centers under Connect-and-Manage","license":"http://creativecommons.org/licenses/by/4.0/","headline":"Gigawatt-scale AI data centers can connect to transmission grids without upgrades using a hierarchical coordination protocol that slashes curtailment while maintaining training workloads.","cross_cats":["cs.SY"],"primary_cat":"eess.SY","authors_text":"Qianwen Xu, Xin Lu","submitted_at":"2026-05-13T20:48:47Z","abstract_excerpt":"Emerging connect-and-manage interconnection practices allow gigawatt-scale artificial intelligence data centers (AIDCs) to connect to the transmission network without prior network upgrades, at the cost of real-time curtailment during grid stress. This paper formalizes the resulting AIDC-transmission system operator (TSO) coordination as a sequential request-acceptance protocol with an explicit curtailment variable and a strict information boundary between the two parties. Physical models are developed on both sides of the point of common coupling: the AIDC is decomposed into frontier training"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":true,"formal_links_present":true},"canonical_record":{"source":{"id":"2605.14109","kind":"arxiv","version":1},"metadata":{"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"eess.SY","submitted_at":"2026-05-13T20:48:47Z","cross_cats_sorted":["cs.SY"],"title_canon_sha256":"ff8a619635730c09074dcc6a31c94aedd8b1acd2d6f64a23e311cd7178cc94b5","abstract_canon_sha256":"fde9f9cfa1dde6a69f9a119c12b96cd316e394e68949a3cf616c8759a803da5c"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-05-17T23:39:12.021288Z","signature_b64":"Q56qyPL900c92LsVLsb8qSFrwvo9mgZIx68aSMHd96Jf7O5ayN19vZVhMmNENbA7CodkYhkNV37mlExTw3zOCw==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"782c6b485a940e720e7baae5a271d4f4db6e148a43dab515ba6657935532a14b","last_reissued_at":"2026-05-17T23:39:12.020777Z","signature_status":"signed_v1","first_computed_at":"2026-05-17T23:39:12.020777Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"Grid Integration of Gigawatt-Scale AI Data Centers under Connect-and-Manage","license":"http://creativecommons.org/licenses/by/4.0/","headline":"Gigawatt-scale AI data centers can connect to transmission grids without upgrades using a hierarchical coordination protocol that slashes curtailment while maintaining training workloads.","cross_cats":["cs.SY"],"primary_cat":"eess.SY","authors_text":"Qianwen Xu, Xin Lu","submitted_at":"2026-05-13T20:48:47Z","abstract_excerpt":"Emerging connect-and-manage interconnection practices allow gigawatt-scale artificial intelligence data centers (AIDCs) to connect to the transmission network without prior network upgrades, at the cost of real-time curtailment during grid stress. This paper formalizes the resulting AIDC-transmission system operator (TSO) coordination as a sequential request-acceptance protocol with an explicit curtailment variable and a strict information boundary between the two parties. Physical models are developed on both sides of the point of common coupling: the AIDC is decomposed into frontier training"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"Case studies with a gigawatt-scale AIDC on the IEEE 39-bus system with Australian market data show that the framework reduces curtailment from 9.1% to 2.8% while preserving 98.1% frontier training workload, that batch training acts as the primary grid-elastic resource with the largest throughput swing during peak demand, and that the on-site battery provides curtailment buffering through active discharge and charge deferral.","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"The TSO's acceptance mapping is completely opaque to the AIDC and can be treated as a robust black-box mechanism whose worst-case behavior is known in advance; if real TSO decisions depend on private information or non-robust criteria not captured by the model, the hierarchical architecture loses its performance guarantees.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"A hierarchical request-acceptance protocol with learning-based planning and robust TSO evaluation reduces curtailment for GW-scale AI data centers from 9.1% to 2.8% while preserving 98.1% of frontier training workload.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"Gigawatt-scale AI data centers can connect to transmission grids without upgrades using a hierarchical coordination protocol that slashes curtailment while maintaining training workloads.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"4f09a954e507b82fa6ceaea4d5fc9387a5502b1968534cbe8bccbc6c75a4f0e0"},"source":{"id":"2605.14109","kind":"arxiv","version":1},"verdict":{"id":"849b79e1-8a93-4c50-8897-ec2519a46c14","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-15T05:01:18.062233Z","strongest_claim":"Case studies with a gigawatt-scale AIDC on the IEEE 39-bus system with Australian market data show that the framework reduces curtailment from 9.1% to 2.8% while preserving 98.1% frontier training workload, that batch training acts as the primary grid-elastic resource with the largest throughput swing during peak demand, and that the on-site battery provides curtailment buffering through active discharge and charge deferral.","one_line_summary":"A hierarchical request-acceptance protocol with learning-based planning and robust TSO evaluation reduces curtailment for GW-scale AI data centers from 9.1% to 2.8% while preserving 98.1% of frontier training workload.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"The TSO's acceptance mapping is completely opaque to the AIDC and can be treated as a robust black-box mechanism whose worst-case behavior is known in advance; if real TSO decisions depend on private information or non-robust criteria not captured by the model, the hierarchical architecture loses its performance guarantees.","pith_extraction_headline":"Gigawatt-scale AI data centers can connect to transmission grids without upgrades using a hierarchical coordination protocol that slashes curtailment while maintaining training workloads."},"references":{"count":27,"sample":[{"doi":"","year":2025,"title":"NVIDIA Launches Omniverse DSX Blueprint, Enabling Global AI Infrastructure Ecosystem to Build Gigawatt -Scale AI Factories,","work_id":"89e6ebbd-2ced-4a04-ae4e-6082ecbef965","ref_index":1,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2025,"title":"The cost of compute: A $7 trillion race to scale data centers,","work_id":"83958039-1209-46b8-aa3f-2590193dae68","ref_index":2,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2025,"title":"I. E. Agency, “Energy and AI,” World Energy Outlook Special Report, 2025","work_id":"ad624471-a350-4528-811a-adb2dfc11aab","ref_index":3,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2026,"title":"Structural alignment for energy –computation co-design,","work_id":"03678f49-4690-43d1-bf5c-6543cd99198f","ref_index":4,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2026,"title":"PJM, stakeholders begin work on Board's plan to reliably integrate large loads,","work_id":"a89d0f68-8ced-4df1-b5dd-a32b9988c14d","ref_index":5,"cited_arxiv_id":"","is_internal_anchor":false}],"resolved_work":27,"snapshot_sha256":"eddab22c6182f0d00d6c2605938aa95a6bf310949336147b7918c0ecea4c55bf","internal_anchors":2},"formal_canon":{"evidence_count":2,"snapshot_sha256":"fb41be7f341bb32b7734722be51fcbdfa0e07ed594effc8e18bc9535810ce7f4"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"2605.14109","created_at":"2026-05-17T23:39:12.020866+00:00"},{"alias_kind":"arxiv_version","alias_value":"2605.14109v1","created_at":"2026-05-17T23:39:12.020866+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2605.14109","created_at":"2026-05-17T23:39:12.020866+00:00"},{"alias_kind":"pith_short_12","alias_value":"PAWGWSC2SQHH","created_at":"2026-05-18T12:33:37.589309+00:00"},{"alias_kind":"pith_short_16","alias_value":"PAWGWSC2SQHHEDT3","created_at":"2026-05-18T12:33:37.589309+00:00"},{"alias_kind":"pith_short_8","alias_value":"PAWGWSC2","created_at":"2026-05-18T12:33:37.589309+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":0,"internal_anchor_count":0,"sample":[]},"formal_canon":{"evidence_count":2,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T","json":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T.json","graph_json":"https://pith.science/api/pith-number/PAWGWSC2SQHHEDT3VLS2E4OU6T/graph.json","events_json":"https://pith.science/api/pith-number/PAWGWSC2SQHHEDT3VLS2E4OU6T/events.json","paper":"https://pith.science/paper/PAWGWSC2"},"agent_actions":{"view_html":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T","download_json":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T.json","view_paper":"https://pith.science/paper/PAWGWSC2","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=2605.14109&json=true","fetch_graph":"https://pith.science/api/pith-number/PAWGWSC2SQHHEDT3VLS2E4OU6T/graph.json","fetch_events":"https://pith.science/api/pith-number/PAWGWSC2SQHHEDT3VLS2E4OU6T/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T/action/timestamp_anchor","attest_storage":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T/action/storage_attestation","attest_author":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T/action/author_attestation","sign_citation":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T/action/citation_signature","submit_replication":"https://pith.science/pith/PAWGWSC2SQHHEDT3VLS2E4OU6T/action/replication_record"}},"created_at":"2026-05-17T23:39:12.020866+00:00","updated_at":"2026-05-17T23:39:12.020866+00:00"}