{"state_type":"pith_open_graph_state","state_version":"1.0","pith_number":"pith:2025:Q4MLSSYQT7ORLRNKFDPU7SQH22","merge_version":"pith-open-graph-merge-v1","event_count":2,"valid_event_count":2,"invalid_event_count":0,"equivocation_count":0,"current":{"canonical_record":{"metadata":{"abstract_canon_sha256":"52cd0de2ef7cfc36db020e22963718b995608236682f28db6df085bdc5e0ec2f","cross_cats_sorted":["hep-ex"],"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"hep-ph","submitted_at":"2025-10-19T08:11:50Z","title_canon_sha256":"fc3a485ca29368bc900b1824bbb9f519ca16dd49392f15a44c278c8ff068f688"},"schema_version":"1.0","source":{"id":"2510.16746","kind":"arxiv","version":5}},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2510.16746","created_at":"2026-06-03T14:05:45Z"},{"alias_kind":"arxiv_version","alias_value":"2510.16746v5","created_at":"2026-06-03T14:05:45Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2510.16746","created_at":"2026-06-03T14:05:45Z"},{"alias_kind":"pith_short_12","alias_value":"Q4MLSSYQT7OR","created_at":"2026-06-03T14:05:45Z"},{"alias_kind":"pith_short_16","alias_value":"Q4MLSSYQT7ORLRNK","created_at":"2026-06-03T14:05:45Z"},{"alias_kind":"pith_short_8","alias_value":"Q4MLSSYQ","created_at":"2026-06-03T14:05:45Z"}],"graph_snapshots":[{"event_id":"sha256:3d31f83ebac7f12e92d23a8b5fd2eca812c79e09bd2e7989403287a821dc2bce","target":"graph","created_at":"2026-06-03T14:05:45Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"graph_snapshot":{"author_claims":{"count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","strong_count":0},"builder_version":"pith-number-builder-2026-05-17-v1","claims":{"count":4,"items":[{"attestation":"unclaimed","claim_id":"C1","kind":"strongest_claim","source":"verdict.strongest_claim","status":"machine_extracted","text":"The detection of dark matter axions in the mass range m_a = 10^{-4}-10^{-3} eV may be feasible using a cylindrical sample with low conductivity σ = 10^{-3} eV, radius R = 80 cm, and B_0 = 7 T, yielding SNR > 1 at T = 4 K."},{"attestation":"unclaimed","claim_id":"C2","kind":"weakest_assumption","source":"verdict.weakest_assumption","status":"machine_extracted","text":"That a macroscopic cylinder of material with conductivity as low as σ = 10^{-3} eV can be fabricated and operated without additional noise sources (e.g., mechanical vibrations, electromagnetic interference) dominating the thermal noise assumed in the SNR formula."},{"attestation":"unclaimed","claim_id":"C3","kind":"one_line_summary","source":"verdict.one_line_summary","status":"machine_extracted","text":"Proposes using low-conductivity cylindrical samples in strong B-fields to detect axion-induced bulk currents, with SNR estimates indicating feasibility for R=80 cm at 4 K."},{"attestation":"unclaimed","claim_id":"C4","kind":"headline","source":"verdict.pith_extraction.headline","status":"machine_extracted","text":"Axions in the 10^{-4} to 10^{-3} eV mass range induce detectable bulk currents in large low-conductivity cylinders placed in strong magnetic fields."}],"snapshot_sha256":"90eaf49c85fe9ca8fa35b77851c4916f26ecb025b261f743d8b31e983382d326"},"formal_canon":{"evidence_count":2,"snapshot_sha256":"9e77f977e66d36e544d6279fe1e53fa51568191d17f62bb2a9516e545b91139f"},"integrity":{"available":true,"clean":true,"detectors_run":[],"endpoint":"/pith/2510.16746/integrity.json","findings":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938","summary":{"advisory":0,"by_detector":{},"critical":0,"informational":0}},"paper":{"abstract_excerpt":"A dark matter axion with mass $m_a$ induces an oscillating electric field in a cylindrical sample placed under a magnetic field $B_0$ parallel to the cylinder axis. When the cylinder is made of a highly electrically conductive material, the induced oscillating current flows only at the surface. In contrast, if the cylinder is composed of a material with small conductivity, e.g. $\\sigma = 10^{-3}\\text{eV}$, the electric current flows inside the bulk of the cylinder. Within the QCD axion model, the current $I$ is estimated as $I(\\sigma=10^{-3}\\text{eV})\\simeq 2.8\\times 10^{-14}\\text{A}g_{\\gamma}","authors_text":"Aiichi Iwazaki","cross_cats":["hep-ex"],"headline":"Axions in the 10^{-4} to 10^{-3} eV mass range induce detectable bulk currents in large low-conductivity cylinders placed in strong magnetic fields.","license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"hep-ph","submitted_at":"2025-10-19T08:11:50Z","title":"A Way of Axion Detection with Mass $10^{-4} \\text{-}10^{-3}$eV Using Cylindrical Sample with Low Electric Conductivity"},"references":{"count":17,"internal_anchors":1,"resolved_work":17,"sample":[{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":1,"title":"R. D. Peccei and H. R. Quinn, Phys. Rev. Lett. 38 (1977) 1440","work_id":"72badd77-9179-41ea-a9b9-14d9774b9104","year":1977},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":2,"title":"S. Weinberg, Phys. Rev. Lett. 40 (1978) 223","work_id":"ac1127fd-2e0b-42ea-b561-1a641b6cc01d","year":1978},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":3,"title":"F. Wilczek, Phys. Rev. Lett. 40 (1978) 279","work_id":"fea62312-777e-4c83-bb24-11de725c6378","year":1978},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":4,"title":"J. Preskill, M. B. Wise and F. Wilczek, Phys. Lett. 120B (1983) 127","work_id":"05d96295-d482-41b0-a418-1f59e743c336","year":1983},{"cited_arxiv_id":"","doi":"","is_internal_anchor":false,"ref_index":5,"title":"L. F. Abbott and P. Sikivie, Phys. Lett. B120 (1983) 133","work_id":"6bc209e2-b419-47c7-b237-fb2123ed9232","year":1983}],"snapshot_sha256":"993934d090e81708ba8b6fcfe26795cb0de23587206bb040b3d3c6fa26f97e20"},"source":{"id":"2510.16746","kind":"arxiv","version":5},"verdict":{"created_at":"2026-05-18T06:42:41.936639Z","id":"0b194aa8-f354-4877-aeb9-c63bcf61f7d9","model_set":{"reader":"grok-4.3"},"one_line_summary":"Proposes using low-conductivity cylindrical samples in strong B-fields to detect axion-induced bulk currents, with SNR estimates indicating feasibility for R=80 cm at 4 K.","pipeline_version":"pith-pipeline@v0.9.0","pith_extraction_headline":"Axions in the 10^{-4} to 10^{-3} eV mass range induce detectable bulk currents in large low-conductivity cylinders placed in strong magnetic fields.","strongest_claim":"The detection of dark matter axions in the mass range m_a = 10^{-4}-10^{-3} eV may be feasible using a cylindrical sample with low conductivity σ = 10^{-3} eV, radius R = 80 cm, and B_0 = 7 T, yielding SNR > 1 at T = 4 K.","weakest_assumption":"That a macroscopic cylinder of material with conductivity as low as σ = 10^{-3} eV can be fabricated and operated without additional noise sources (e.g., mechanical vibrations, electromagnetic interference) dominating the thermal noise assumed in the SNR formula."}},"verdict_id":"0b194aa8-f354-4877-aeb9-c63bcf61f7d9"}}],"author_attestations":[],"timestamp_anchors":[],"storage_attestations":[],"citation_signatures":[],"replication_records":[],"corrections":[],"mirror_hints":[],"record_created":{"event_id":"sha256:5c22c5243f80f20d8e70172207694a4f3e3e297f73b0b4d377d3f32d1006bd63","target":"record","created_at":"2026-06-03T14:05:45Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"attestation_state":"computed","canonical_record":{"metadata":{"abstract_canon_sha256":"52cd0de2ef7cfc36db020e22963718b995608236682f28db6df085bdc5e0ec2f","cross_cats_sorted":["hep-ex"],"license":"http://creativecommons.org/licenses/by/4.0/","primary_cat":"hep-ph","submitted_at":"2025-10-19T08:11:50Z","title_canon_sha256":"fc3a485ca29368bc900b1824bbb9f519ca16dd49392f15a44c278c8ff068f688"},"schema_version":"1.0","source":{"id":"2510.16746","kind":"arxiv","version":5}},"canonical_sha256":"8718b94b109fdd15c5aa28df4fca07d699be6ebc26f67eebd82781bfababb7de","receipt":{"algorithm":"ed25519","builder_version":"pith-number-builder-2026-05-17-v1","canonical_sha256":"8718b94b109fdd15c5aa28df4fca07d699be6ebc26f67eebd82781bfababb7de","first_computed_at":"2026-06-03T14:05:45.817262Z","key_id":"pith-v1-2026-05","kind":"pith_receipt","last_reissued_at":"2026-06-03T14:05:45.817262Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","receipt_version":"0.3","signature_b64":"Q5z4Yfa3dYQZKC626mxFrMlXlU9Tbpn7fI2luQ9C/LT4kshs+mlMLt+F+Y1EVotDEI1Mnc3OK2KanshziPL7Aw==","signature_status":"signed_v1","signed_at":"2026-06-03T14:05:45.817710Z","signed_message":"canonical_sha256_bytes"},"source_id":"2510.16746","source_kind":"arxiv","source_version":5}}},"equivocations":[],"invalid_events":[],"applied_event_ids":["sha256:5c22c5243f80f20d8e70172207694a4f3e3e297f73b0b4d377d3f32d1006bd63","sha256:3d31f83ebac7f12e92d23a8b5fd2eca812c79e09bd2e7989403287a821dc2bce"],"state_sha256":"d9d04d3c5cc82415576f0cfd7d92cf501869caffb6f73a0c00b2d47168ff5e7d"}