{"state_type":"pith_open_graph_state","state_version":"1.0","pith_number":"pith:2025:VUTAL3YPQ6XF2RNH6FTTYHUPDK","merge_version":"pith-open-graph-merge-v1","event_count":2,"valid_event_count":2,"invalid_event_count":0,"equivocation_count":0,"current":{"canonical_record":{"metadata":{"abstract_canon_sha256":"a3f96d8306294c8e111969434cf027cd6496ea64f225ac97e7c13de30c390a31","cross_cats_sorted":["quant-ph"],"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"physics.ins-det","submitted_at":"2025-05-26T12:45:30Z","title_canon_sha256":"875a9fc7f5d36267a9ce937a40a5f452c7f05838e279be7d7d2b9ebdabe17398"},"schema_version":"1.0","source":{"id":"2505.19922","kind":"arxiv","version":4}},"source_aliases":[{"alias_kind":"arxiv","alias_value":"2505.19922","created_at":"2026-06-26T01:15:44Z"},{"alias_kind":"arxiv_version","alias_value":"2505.19922v4","created_at":"2026-06-26T01:15:44Z"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2505.19922","created_at":"2026-06-26T01:15:44Z"},{"alias_kind":"pith_short_12","alias_value":"VUTAL3YPQ6XF","created_at":"2026-06-26T01:15:44Z"},{"alias_kind":"pith_short_16","alias_value":"VUTAL3YPQ6XF2RNH","created_at":"2026-06-26T01:15:44Z"},{"alias_kind":"pith_short_8","alias_value":"VUTAL3YP","created_at":"2026-06-26T01:15:44Z"}],"graph_snapshots":[{"event_id":"sha256:92bad8e5f9ffaa17603160ce6ee673086c18c31b4c1fd8affcd7383866745c4f","target":"graph","created_at":"2026-06-26T01:15:44Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"graph_snapshot":{"author_claims":{"count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","strong_count":0},"builder_version":"pith-number-builder-2026-05-17-v1","claims":{"count":4,"items":[{"attestation":"unclaimed","claim_id":"C1","kind":"strongest_claim","source":"verdict.strongest_claim","status":"machine_extracted","text":"The system exploits the Short-Open-Load-Reciprocal technique to realize error-corrected cryogenic measurements within a single cooling cycle, with calibration standards referenced to SI-traceable room-temperature measurements and a numerical approach to evaluate response shift upon cooling for the uncertainty budget; test result on a 20 dB attenuator yields 20.70 +/- 0.08 dB at 6 GHz."},{"attestation":"unclaimed","claim_id":"C2","kind":"weakest_assumption","source":"verdict.weakest_assumption","status":"machine_extracted","text":"The numerical approach used to evaluate the response shift of the artifacts upon cooling accurately captures all relevant cryogenic changes and derives a valid additional uncertainty contribution without significant unmodeled systematic effects or biases (abstract: 'a numerical approach is used to evaluate the response shift of the artifacts upon cooling and to derive an additional cryogenic uncertainty contribution for the measurement uncertainty budget')."},{"attestation":"unclaimed","claim_id":"C3","kind":"one_line_summary","source":"verdict.one_line_summary","status":"machine_extracted","text":"A calibration strategy and uncertainty budget for full two-port S-parameter measurements at mK temperatures over 4-12 GHz using SOLR in coaxial line with SI-traceable room-temperature references and numerical cryo-shift modeling."},{"attestation":"unclaimed","claim_id":"C4","kind":"headline","source":"verdict.pith_extraction.headline","status":"machine_extracted","text":"A single-cycle Short-Open-Load-Reciprocal calibration referenced to room-temperature standards enables full two-port S-parameter measurements at millikelvin temperatures with a complete uncertainty budget."}],"snapshot_sha256":"bfbe2a49120b161c1e923f20c6d0d09d96bd42ee502ecc95f06fdcb73254ce66"},"formal_canon":{"evidence_count":2,"snapshot_sha256":"156be70805ee9571ea23849dbbdbd2beb497d104cf260b3b28aebb0bb5774c01"},"integrity":{"available":true,"clean":true,"detectors_run":[],"endpoint":"/pith/2505.19922/integrity.json","findings":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938","summary":{"advisory":0,"by_detector":{},"critical":0,"informational":0}},"paper":{"abstract_excerpt":"This paper describes the developed setup and characterization approach for full two-port calibrated S-parameter measurements at cryogenic temperatures, together with a complete uncertainty budget. The system developed at the Istituto Nazionale di Ricerca Metrologica (INRiM, Italy), exploits the Short-Open-Load-Reciprocal technique to realize error-corrected cryogenic measurements within a single cooling cycle. The system operates down to mK temperatures over the 4-12 GHz band in coaxial line. Calibration standards are referenced to SI-traceable room-temperature measurements, while a numerical ","authors_text":"Alessandro Alocco, Andrea Celotto, Bernardo Galvano, Ehsan Shokrolahzade, Emanuele Enrico, Faisal A. Mubarak, Luca Fasolo, Luca Oberto, Marco Spirito, Paolo Terzi","cross_cats":["quant-ph"],"headline":"A single-cycle Short-Open-Load-Reciprocal calibration referenced to room-temperature standards enables full two-port S-parameter measurements at millikelvin temperatures with a complete uncertainty budget.","license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"physics.ins-det","submitted_at":"2025-05-26T12:45:30Z","title":"Full Two-Port S-Parameters at mK Temperatures: a Calibration Strategy and Uncertainty Budget"},"references":{"count":0,"internal_anchors":0,"resolved_work":0,"sample":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"2505.19922","kind":"arxiv","version":4},"verdict":{"created_at":"2026-05-19T13:34:14.090187Z","id":"2e40c69c-8e19-4d8d-baca-f7b820f0aee7","model_set":{"reader":"grok-4.3"},"one_line_summary":"A calibration strategy and uncertainty budget for full two-port S-parameter measurements at mK temperatures over 4-12 GHz using SOLR in coaxial line with SI-traceable room-temperature references and numerical cryo-shift modeling.","pipeline_version":"pith-pipeline@v0.9.0","pith_extraction_headline":"A single-cycle Short-Open-Load-Reciprocal calibration referenced to room-temperature standards enables full two-port S-parameter measurements at millikelvin temperatures with a complete uncertainty budget.","strongest_claim":"The system exploits the Short-Open-Load-Reciprocal technique to realize error-corrected cryogenic measurements within a single cooling cycle, with calibration standards referenced to SI-traceable room-temperature measurements and a numerical approach to evaluate response shift upon cooling for the uncertainty budget; test result on a 20 dB attenuator yields 20.70 +/- 0.08 dB at 6 GHz.","weakest_assumption":"The numerical approach used to evaluate the response shift of the artifacts upon cooling accurately captures all relevant cryogenic changes and derives a valid additional uncertainty contribution without significant unmodeled systematic effects or biases (abstract: 'a numerical approach is used to evaluate the response shift of the artifacts upon cooling and to derive an additional cryogenic uncertainty contribution for the measurement uncertainty budget')."}},"verdict_id":"2e40c69c-8e19-4d8d-baca-f7b820f0aee7"}}],"author_attestations":[],"timestamp_anchors":[],"storage_attestations":[],"citation_signatures":[],"replication_records":[],"corrections":[],"mirror_hints":[],"record_created":{"event_id":"sha256:641c87658d2f7cb7738ed5bf149664785cee96a1e0cdfbcb8e82ecb9ddb157cc","target":"record","created_at":"2026-06-26T01:15:44Z","signer":{"key_id":"pith-v1-2026-05","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","signer_id":"pith.science","signer_type":"pith_registry"},"payload":{"attestation_state":"computed","canonical_record":{"metadata":{"abstract_canon_sha256":"a3f96d8306294c8e111969434cf027cd6496ea64f225ac97e7c13de30c390a31","cross_cats_sorted":["quant-ph"],"license":"http://creativecommons.org/licenses/by-nc-nd/4.0/","primary_cat":"physics.ins-det","submitted_at":"2025-05-26T12:45:30Z","title_canon_sha256":"875a9fc7f5d36267a9ce937a40a5f452c7f05838e279be7d7d2b9ebdabe17398"},"schema_version":"1.0","source":{"id":"2505.19922","kind":"arxiv","version":4}},"canonical_sha256":"ad2605ef0f87ae5d45a7f1673c1e8f1a9f6e3e368ca8175bc76e4fcedd804c10","receipt":{"algorithm":"ed25519","builder_version":"pith-number-builder-2026-05-17-v1","canonical_sha256":"ad2605ef0f87ae5d45a7f1673c1e8f1a9f6e3e368ca8175bc76e4fcedd804c10","first_computed_at":"2026-06-26T01:15:44.294447Z","key_id":"pith-v1-2026-05","kind":"pith_receipt","last_reissued_at":"2026-06-26T01:15:44.294447Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54","receipt_version":"0.3","signature_b64":"CMSz06nYqCg/Dr+XXgxjHPM8xnbUipk+DZT+CdFn87Zyzq5ciSItg5hDT88YHU7X8I1E0YtolraWWDB/bCxhAA==","signature_status":"signed_v1","signed_at":"2026-06-26T01:15:44.294916Z","signed_message":"canonical_sha256_bytes"},"source_id":"2505.19922","source_kind":"arxiv","source_version":4}}},"equivocations":[],"invalid_events":[],"applied_event_ids":["sha256:641c87658d2f7cb7738ed5bf149664785cee96a1e0cdfbcb8e82ecb9ddb157cc","sha256:92bad8e5f9ffaa17603160ce6ee673086c18c31b4c1fd8affcd7383866745c4f"],"state_sha256":"3cceabb7c9e90eb9b5d0f8481c22df27e50fc35dc87a73c4701799fe23181a19"}