{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2026:XDJCVTPF6BNLERKSUHNP453YB6","short_pith_number":"pith:XDJCVTPF","schema_version":"1.0","canonical_sha256":"b8d22acde5f05ab24552a1dafe77780f8cd8a6f72f74f7eb2d6ce1aee467913f","source":{"kind":"arxiv","id":"2605.13613","version":1},"attestation_state":"computed","paper":{"title":"Design of Magnetic Continuum Robots with Tunable Force Response Using Rotational Ring Pairs","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"Rotational ring pairs let magnetic continuum robots tune tip direction and intensity online.","cross_cats":[],"primary_cat":"cs.RO","authors_text":"Alex Sayres, Giovanni Pittiglio","submitted_at":"2026-05-13T14:44:19Z","abstract_excerpt":"In this paper, we discuss a novel continuum robot design that enables the online tuning of the magnetic response at its tip. The proposed method allows for the change of both effective magnetic direction and intensity, introducing steering DOF without the need to control the external fields. This is unattainable with classical designs, which rely on fixed internal magnetic content and steer solely under the effect of a controllable magnetic field. The proposed robot design can be used in both controllable and fixed magnetic fields, potentially widening the clinical applicability of these robot"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":true,"formal_links_present":true},"canonical_record":{"source":{"id":"2605.13613","kind":"arxiv","version":1},"metadata":{"license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","primary_cat":"cs.RO","submitted_at":"2026-05-13T14:44:19Z","cross_cats_sorted":[],"title_canon_sha256":"a18af27f14738c33ec933322b644663485d963bc98930abf967b9feb410067a3","abstract_canon_sha256":"595325e568042f93e0a70e68e34240d47dee29201df4d273a9b4300a2f1942c7"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-05-18T02:44:18.010068Z","signature_b64":"jKkoWoOLSrqIQDli68ppnlJmgF9ihZYsIbv4MYnhQ3Sw6ZDiQ0MUqMumDsZlSDNx/05aettbNhm7Czgm9aoNCA==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"b8d22acde5f05ab24552a1dafe77780f8cd8a6f72f74f7eb2d6ce1aee467913f","last_reissued_at":"2026-05-18T02:44:18.009569Z","signature_status":"signed_v1","first_computed_at":"2026-05-18T02:44:18.009569Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"Design of Magnetic Continuum Robots with Tunable Force Response Using Rotational Ring Pairs","license":"http://arxiv.org/licenses/nonexclusive-distrib/1.0/","headline":"Rotational ring pairs let magnetic continuum robots tune tip direction and intensity online.","cross_cats":[],"primary_cat":"cs.RO","authors_text":"Alex Sayres, Giovanni Pittiglio","submitted_at":"2026-05-13T14:44:19Z","abstract_excerpt":"In this paper, we discuss a novel continuum robot design that enables the online tuning of the magnetic response at its tip. The proposed method allows for the change of both effective magnetic direction and intensity, introducing steering DOF without the need to control the external fields. This is unattainable with classical designs, which rely on fixed internal magnetic content and steer solely under the effect of a controllable magnetic field. The proposed robot design can be used in both controllable and fixed magnetic fields, potentially widening the clinical applicability of these robot"},"claims":{"count":4,"items":[{"kind":"strongest_claim","text":"The proposed robot design can be used in both controllable and fixed magnetic fields, potentially widening the clinical applicability of these robots. We experimentally show a max tip deflection of 33.8 mm from the resting state (23 % of the length of the robot) with a model based on modified beam theory that captures the mechanical behavior with a mean absolute tip tracking error of 1.86 mm (1.2 % of the length).","source":"verdict.strongest_claim","status":"machine_extracted","claim_id":"C1","attestation":"unclaimed"},{"kind":"weakest_assumption","text":"The modified beam theory model accurately captures the mechanical behavior of the continuum robot under varying ring rotations without requiring additional correction terms or assumptions about friction, material nonlinearity, or ring interaction effects.","source":"verdict.weakest_assumption","status":"machine_extracted","claim_id":"C2","attestation":"unclaimed"},{"kind":"one_line_summary","text":"Magnetic continuum robot using rotational ring pairs achieves tunable tip response with 33.8 mm max deflection and 1.86 mm mean modeling error via modified beam theory.","source":"verdict.one_line_summary","status":"machine_extracted","claim_id":"C3","attestation":"unclaimed"},{"kind":"headline","text":"Rotational ring pairs let magnetic continuum robots tune tip direction and intensity online.","source":"verdict.pith_extraction.headline","status":"machine_extracted","claim_id":"C4","attestation":"unclaimed"}],"snapshot_sha256":"ad2cf1779d03f0074308f054564608d5e055f44eda0c9a6e0ff54c95077534d6"},"source":{"id":"2605.13613","kind":"arxiv","version":1},"verdict":{"id":"c02d5a37-246b-4e3d-9301-03138838b0df","model_set":{"reader":"grok-4.3"},"created_at":"2026-05-14T18:33:35.826029Z","strongest_claim":"The proposed robot design can be used in both controllable and fixed magnetic fields, potentially widening the clinical applicability of these robots. We experimentally show a max tip deflection of 33.8 mm from the resting state (23 % of the length of the robot) with a model based on modified beam theory that captures the mechanical behavior with a mean absolute tip tracking error of 1.86 mm (1.2 % of the length).","one_line_summary":"Magnetic continuum robot using rotational ring pairs achieves tunable tip response with 33.8 mm max deflection and 1.86 mm mean modeling error via modified beam theory.","pipeline_version":"pith-pipeline@v0.9.0","weakest_assumption":"The modified beam theory model accurately captures the mechanical behavior of the continuum robot under varying ring rotations without requiring additional correction terms or assumptions about friction, material nonlinearity, or ring interaction effects.","pith_extraction_headline":"Rotational ring pairs let magnetic continuum robots tune tip direction and intensity online."},"references":{"count":19,"sample":[{"doi":"","year":2017,"title":"Magnetic control of continuum devices,","work_id":"c65500d9-7fce-4495-9e4f-34042731b958","ref_index":1,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2024,"title":"Remote magnetic navigation enables precision telesurgery,","work_id":"e3f87779-f949-464f-aadd-ba8be23b5097","ref_index":2,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2024,"title":"Continuum Robot Shape Estimation Using Magnetic Ball Chains,","work_id":"625c4616-a52b-46aa-ad14-2e29e4a1f26e","ref_index":3,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2022,"title":"Telerobotic neurovascular interventions with magnetic manipulation,","work_id":"22241ead-c5b8-4928-8d1a-1e5e04dc16c6","ref_index":4,"cited_arxiv_id":"","is_internal_anchor":false},{"doi":"","year":2023,"title":"Closed Loop Static Control of Multi- Magnet Soft Continuum Robots,","work_id":"8ada4718-ff81-4fe1-a5f6-251db6b65328","ref_index":5,"cited_arxiv_id":"","is_internal_anchor":false}],"resolved_work":19,"snapshot_sha256":"147ec041d90b127b1009e697481735e645abb1c9a20c0b63c3b3907987877263","internal_anchors":0},"formal_canon":{"evidence_count":2,"snapshot_sha256":"1ac5615b337a79306adfcae8227098c5c944e8a65bdb241c0e031d81d66193e1"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"2605.13613","created_at":"2026-05-18T02:44:18.009653+00:00"},{"alias_kind":"arxiv_version","alias_value":"2605.13613v1","created_at":"2026-05-18T02:44:18.009653+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.2605.13613","created_at":"2026-05-18T02:44:18.009653+00:00"},{"alias_kind":"pith_short_12","alias_value":"XDJCVTPF6BNL","created_at":"2026-05-18T12:33:37.589309+00:00"},{"alias_kind":"pith_short_16","alias_value":"XDJCVTPF6BNLERKS","created_at":"2026-05-18T12:33:37.589309+00:00"},{"alias_kind":"pith_short_8","alias_value":"XDJCVTPF","created_at":"2026-05-18T12:33:37.589309+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":0,"internal_anchor_count":0,"sample":[]},"formal_canon":{"evidence_count":2,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6","json":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6.json","graph_json":"https://pith.science/api/pith-number/XDJCVTPF6BNLERKSUHNP453YB6/graph.json","events_json":"https://pith.science/api/pith-number/XDJCVTPF6BNLERKSUHNP453YB6/events.json","paper":"https://pith.science/paper/XDJCVTPF"},"agent_actions":{"view_html":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6","download_json":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6.json","view_paper":"https://pith.science/paper/XDJCVTPF","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=2605.13613&json=true","fetch_graph":"https://pith.science/api/pith-number/XDJCVTPF6BNLERKSUHNP453YB6/graph.json","fetch_events":"https://pith.science/api/pith-number/XDJCVTPF6BNLERKSUHNP453YB6/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6/action/timestamp_anchor","attest_storage":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6/action/storage_attestation","attest_author":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6/action/author_attestation","sign_citation":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6/action/citation_signature","submit_replication":"https://pith.science/pith/XDJCVTPF6BNLERKSUHNP453YB6/action/replication_record"}},"created_at":"2026-05-18T02:44:18.009653+00:00","updated_at":"2026-05-18T02:44:18.009653+00:00"}