{"record_type":"pith_number_record","schema_url":"https://pith.science/schemas/pith-number/v1.json","pith_number":"pith:2006:ZZKF7ITQZITREBRA362J63PCPK","short_pith_number":"pith:ZZKF7ITQ","schema_version":"1.0","canonical_sha256":"ce545fa270ca27120620dfb49f6de27ab94da692d526654ff444f9e1c3e83c1b","source":{"kind":"arxiv","id":"physics/0607191","version":1},"attestation_state":"computed","paper":{"title":"Neutron imaging with a Micromegas detector","license":"","headline":"","cross_cats":[],"primary_cat":"physics.ins-det","authors_text":"A. Giganon, A. Menelle, A. Pluquet, F. Jeanneau, H. Friedrich, I. Espagnon, I. Giomataris, J. Pancin, L. R. Rodriguez, M. Voytchev, R. Junca, S. Andriamonje, V. Dangendorf","submitted_at":"2006-07-21T15:01:12Z","abstract_excerpt":"The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a 1D Micromegas prototype. The number of pillars supporting the micromesh is too large and leads to local losses of efficiency that distort the tomographic reconstruction. Nevertheless, this first tomogra"},"verification_status":{"content_addressed":true,"pith_receipt":true,"author_attested":false,"weak_author_claims":0,"strong_author_claims":0,"externally_anchored":false,"storage_verified":false,"citation_signatures":0,"replication_records":0,"graph_snapshot":true,"references_resolved":false,"formal_links_present":false},"canonical_record":{"source":{"id":"physics/0607191","kind":"arxiv","version":1},"metadata":{"license":"","primary_cat":"physics.ins-det","submitted_at":"2006-07-21T15:01:12Z","cross_cats_sorted":[],"title_canon_sha256":"ccd9ef6438c6573c0cd5570e3740b2a5aa6a3485ee86a027f7fc1f150d5ade4b","abstract_canon_sha256":"5bd6bed1ef08c64ffd1bf67a466a46a99ccb517430020de5e56ed29f37325f76"},"schema_version":"1.0"},"receipt":{"kind":"pith_receipt","key_id":"pith-v1-2026-05","algorithm":"ed25519","signed_at":"2026-07-04T17:02:43.772160Z","signature_b64":"TLKm840GwhWSOxmKagGzw7qsei4nu8bHF9PHIDDRGqgpFFPUm4Mb40Q1CLiV8LksHygoWGk+zHw7hBPW8TdVDg==","signed_message":"canonical_sha256_bytes","builder_version":"pith-number-builder-2026-05-17-v1","receipt_version":"0.3","canonical_sha256":"ce545fa270ca27120620dfb49f6de27ab94da692d526654ff444f9e1c3e83c1b","last_reissued_at":"2026-07-04T17:02:43.771783Z","signature_status":"signed_v1","first_computed_at":"2026-07-04T17:02:43.771783Z","public_key_fingerprint":"8d4b5ee74e4693bcd1df2446408b0d54"},"graph_snapshot":{"paper":{"title":"Neutron imaging with a Micromegas detector","license":"","headline":"","cross_cats":[],"primary_cat":"physics.ins-det","authors_text":"A. Giganon, A. Menelle, A. Pluquet, F. Jeanneau, H. Friedrich, I. Espagnon, I. Giomataris, J. Pancin, L. R. Rodriguez, M. Voytchev, R. Junca, S. Andriamonje, V. Dangendorf","submitted_at":"2006-07-21T15:01:12Z","abstract_excerpt":"The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a 1D Micromegas prototype. The number of pillars supporting the micromesh is too large and leads to local losses of efficiency that distort the tomographic reconstruction. Nevertheless, this first tomogra"},"claims":{"count":0,"items":[],"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"source":{"id":"physics/0607191","kind":"arxiv","version":1},"verdict":{"id":null,"model_set":{},"created_at":null,"strongest_claim":"","one_line_summary":"","pipeline_version":null,"weakest_assumption":"","pith_extraction_headline":""},"integrity":{"clean":true,"summary":{"advisory":0,"critical":0,"by_detector":{},"informational":0},"endpoint":"/pith/physics/0607191/integrity.json","findings":[],"available":true,"detectors_run":[],"snapshot_sha256":"c28c3603d3b5d939e8dc4c7e95fa8dfce3d595e45f758748cecf8e644a296938"},"references":{"count":0,"sample":[],"resolved_work":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57","internal_anchors":0},"formal_canon":{"evidence_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"author_claims":{"count":0,"strong_count":0,"snapshot_sha256":"258153158e38e3291e3d48162225fcdb2d5a3ed65a07baac614ab91432fd4f57"},"builder_version":"pith-number-builder-2026-05-17-v1"},"aliases":[{"alias_kind":"arxiv","alias_value":"physics/0607191","created_at":"2026-07-04T17:02:43.771846+00:00"},{"alias_kind":"arxiv_version","alias_value":"physics/0607191v1","created_at":"2026-07-04T17:02:43.771846+00:00"},{"alias_kind":"doi","alias_value":"10.48550/arxiv.physics/0607191","created_at":"2026-07-04T17:02:43.771846+00:00"},{"alias_kind":"pith_short_12","alias_value":"ZZKF7ITQZITR","created_at":"2026-07-04T17:02:43.771846+00:00"},{"alias_kind":"pith_short_16","alias_value":"ZZKF7ITQZITREBRA","created_at":"2026-07-04T17:02:43.771846+00:00"},{"alias_kind":"pith_short_8","alias_value":"ZZKF7ITQ","created_at":"2026-07-04T17:02:43.771846+00:00"}],"events":[],"event_summary":{},"paper_claims":[],"inbound_citations":{"count":1,"internal_anchor_count":1,"sample":[{"citing_arxiv_id":"2509.08138","citing_title":"Spatial resolution studies with the BabyIAXO Micromegas prototype","ref_index":28,"is_internal_anchor":true}]},"formal_canon":{"evidence_count":0,"sample":[],"anchors":[]},"links":{"html":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK","json":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK.json","graph_json":"https://pith.science/api/pith-number/ZZKF7ITQZITREBRA362J63PCPK/graph.json","events_json":"https://pith.science/api/pith-number/ZZKF7ITQZITREBRA362J63PCPK/events.json","paper":"https://pith.science/paper/ZZKF7ITQ"},"agent_actions":{"view_html":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK","download_json":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK.json","view_paper":"https://pith.science/paper/ZZKF7ITQ","resolve_alias":"https://pith.science/api/pith-number/resolve?arxiv=physics/0607191&json=true","fetch_graph":"https://pith.science/api/pith-number/ZZKF7ITQZITREBRA362J63PCPK/graph.json","fetch_events":"https://pith.science/api/pith-number/ZZKF7ITQZITREBRA362J63PCPK/events.json","actions":{"anchor_timestamp":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK/action/timestamp_anchor","attest_storage":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK/action/storage_attestation","attest_author":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK/action/author_attestation","sign_citation":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK/action/citation_signature","submit_replication":"https://pith.science/pith/ZZKF7ITQZITREBRA362J63PCPK/action/replication_record"}},"created_at":"2026-07-04T17:02:43.771846+00:00","updated_at":"2026-07-04T17:02:43.771846+00:00"}