Pith sign in

REVIEW 1 cited by

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2005.09859 v1 pith:P2V6GYXW submitted 2020-05-20 physics.med-ph eess.IV

A deep learning approach for virtual monochromatic spectral CT imaging with a standard single energy CT scanner

classification physics.med-ph eess.IV
keywords imagesvmctdectimageimagingsectachievedapproach
verification ladder T0 review T1 audit T2 compute T3 formal T4 reserved
0 comments
read the original abstract

Purpose/Objectives: To develop and assess a strategy of using deep learning (DL) to generate virtual monochromatic CT (VMCT) images from a single-energy CT (SECT) scan. Materials/Methods: The proposed data-driven VMCT imaging consists of two steps: (i) using a supervised DL model trained with a large number of 100 kV and 140 kV dual-energy CT (DECT) image pairs to produce the corresponding high-energy CT image from a low-energy image; and (ii) reconstructing VMCT images with energy ranging from 40 to 150 keV. To evaluate the performance of the method, we retrospectively studied 6,767 abdominal DECT images. The VMCT images reconstructed using both DL-derived DECT (DL-DECT) images and the images from DECT scanner were compared quantitatively. Paired-sample t-tests were used for statistical analysis to show the consistency and precision of calculated HU values. Results: Excellent agreement was found between the DL-DECT and the ground truth DECT images (p values ranged from 0.50 to 0.95). Noise reduction up to 68% (from 163 HU to 51 HU) was achieved for DL-based VMCT imaging as compared to that obtained by using the standard DECT. For the DL-based VMCT, the maximum iodine contrast-to-noise ratio (CNR) for each patient (ranging from 15.1 to 16.6) was achieved at 40 keV. In addition to the enormous benefit of VMCT acquisition with merely a SECT image, an improvement of CNR as high as 55% (from 10.7 to 16.6) was attained with the proposed approach. Conclusions: This study demonstrates that high-quality VMCT images can be obtained with only a SECT scan.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.

Forward citations

Cited by 1 Pith paper

Reviewed papers in the Pith corpus that reference this work. Sorted by Pith novelty score.

  1. A unified deeplearning framework for contrast-phase-specific virtual monochromatic imaging

    eess.IV 2026-05 unverdicted novelty 5.0

    Unified deep learning framework synthesizes contrast-phase-specific 50 keV virtual monochromatic images from single-energy CT using DECT-derived training pairs and phase priors.