A boron-coated silicon neutron counter with a polyethylene moderator is simulated for rover-based lunar water detection, but the headline sensitivity of 0.01 wt% H2O is not supported by the paper's own calculations.
Title resolution pending
1 Pith paper cite this work. Polarity classification is still indexing.
1
Pith paper citing it
fields
physics.ins-det 1years
2025 1verdicts
REJECT 1representative citing papers
citing papers explorer
-
A compact, low-power epithermal neutron counter for lunar water detection
A boron-coated silicon neutron counter with a polyethylene moderator is simulated for rover-based lunar water detection, but the headline sensitivity of 0.01 wt% H2O is not supported by the paper's own calculations.