Pith. sign in

Optimal placement of inertia and primary control : a matrix perturbation theory approach

1 Pith paper cite this work. Polarity classification is still indexing.

1 Pith paper citing it
abstract

The increasing penetration of inertialess new renewable energy sources reduces the overall mechanical inertia available in power grids and accordingly raises a number of issues of grid stability over short to medium time scales. It has been suggested that this reduction of overall inertia can be compensated to some extent by the deployment of substitution inertia - synthetic inertia, flywheels or synchronous condensers. Of particular importance is to optimize the placement of the limited available substitution inertia, to mitigate voltage angle and frequency disturbances following a fault such as an abrupt power loss. Performance measures in the form of H2-norms have been recently introduced to evaluate the overall magnitude of such disturbances on an electric power grid. However, despite the mathematical conveniance of these measures, analytical results can be obtained only under rather restrictive assumptions of uniform damping ratio, or homogeneous distribution of inertia and/or primary control in the system. Here, we introduce matrix perturbation theory to obtain analytical results for optimal inertia and primary control placement where both are heterogeneous. Armed with that efficient tool, we construct two simple algorithms that independently determine the optimal geographical distribution of inertia and primary control. These algorithms are then implemented on a model of the synchronous transmission grid of continental Europe. We find that the optimal distribution of inertia is geographically homogeneous but that primary control should be mainly located on the slow modes of the network, where the intrinsic grid dynamics takes more time to damp frequency disturbances.

citation-role summary

background 1

citation-polarity summary

fields

eess.SY 1

years

2019 1

verdicts

CONDITIONAL 1

roles

background 1

polarities

unclear 1

representative citing papers

Dynamic Droop Control in Low-inertia Power Systems

eess.SY · 2019-08-28 · conditional · novelty 6.0

A dynamic droop controller, iDroop, decouples dynamic frequency performance from steady-state effort share, overcoming limitations of droop control and virtual inertia in low-inertia power systems.

citing papers explorer

Showing 1 of 1 citing paper.

  • Dynamic Droop Control in Low-inertia Power Systems eess.SY · 2019-08-28 · conditional · none · ref 16 · internal anchor

    A dynamic droop controller, iDroop, decouples dynamic frequency performance from steady-state effort share, overcoming limitations of droop control and virtual inertia in low-inertia power systems.