Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility

1 Pith paper cite this work. Polarity classification is still indexing.

1 Pith paper citing it
abstract

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $\sigma_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.

citation-role summary

background 1

citation-polarity summary

fields

hep-ph 1

years

2024 1

verdicts

CONDITIONAL 1

roles

background 1

polarities

unclear 1

representative citing papers

citing papers explorer

Showing 1 of 1 citing paper.