Experimental fringe-field mapping of three 3 T MRI scanners shows maximum field differences of 0.5 T and gradient differences of 1.64 T/m between different manufacturers, and 0.17 T and 0.5 T/m within the same manufacturer.
Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches