Check on the features of potted 20-inch PMTs with 1F3 electronics prototype at Pan-Asia

1 Pith paper cite this work. Polarity classification is still indexing.

1 Pith paper citing it
abstract

The Jiangmen underground neutrino observatory (JUNO) is a neutrino project with a 20-kton liquid scintillator detector located at 700-m underground. The large 20-inch PMTs are one of the crucial components of the JUNO experiment aiming to precision neutrino measurements with better than 3% energy resolution at 1 MeV. The excellent energy resolution and a large fiducial volume provide many exciting opportunities for addressing important topics in neutrino and astro-particle physics. With the container #D at JUNO Pan-Asia PMT testing and potting station, the features of waterproof potted 20-inch PMTs were measured with JUNO 1F3 electronics prototype in waveform and charge, which are valuable for better understanding on the performance of the waterproof potted PMTs and the JUNO 1F3 electronics. In this paper, basic features of JUNO 1F3 electronics prototype run at Pan-Asia will be introduced, followed by an analysis of the waterproof potted 20-inch PMTs and a comparison with the results from commercial electronics used by the container #A and #B.

citation-role summary

background 1

citation-polarity summary

years

2025 1

verdicts

CONDITIONAL 1

roles

background 1

polarities

unclear 1

representative citing papers

Dark Count Rate Stability of JUNO 20-inch PMTs in Mass Testing

physics.ins-det · 2025-06-18 · conditional · novelty 5.0

JUNO's two PMT types differ strongly in dark count rate stability: NNVT MCP-PMTs need about 50 hours to cool and shift 4-12% per degree Celsius with temperature, while HPK dynode PMTs stabilize faster and shift only about 2% per degree.

citing papers explorer

Showing 1 of 1 citing paper.

  • Dark Count Rate Stability of JUNO 20-inch PMTs in Mass Testing physics.ins-det · 2025-06-18 · conditional · none · ref 19 · internal anchor

    JUNO's two PMT types differ strongly in dark count rate stability: NNVT MCP-PMTs need about 50 hours to cool and shift 4-12% per degree Celsius with temperature, while HPK dynode PMTs stabilize faster and shift only about 2% per degree.