Pith. sign in

Boireau et al

1 Pith paper cite this work. Polarity classification is still indexing.

1 Pith paper citing it
abstract

Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides an new tool to assess both the thermal power and the fissile content of the whole nuclear core and could be used by the Inter- national Agency for Atomic Energy (IAEA) to enhance the Safeguards of civil nuclear reactors. Deployed at only 7.2m away from the compact Osiris research reactor core (70MW) operating at the Saclay research centre of the French Alternative Energies and Atomic Energy Commission (CEA), the experiment also exhibits a well-suited configuration to search for a new short baseline oscillation. We report the first results of the Nucifer experiment, describing the performances of the 0.85m3 detector remotely operating at a shallow depth equivalent to 12m of water and under intense background radiation conditions. Based on 145 (106) days of data with reactor ON (OFF), leading to the detection of an estimated 40760 electron antineutrinos, the mean number of detected antineutrinos is 281 +- 7(stat) +- 18(syst) electron antineutrinos/day, in agreement with the prediction 277(23) electron antineutrinos/day. Due the the large background no conclusive results on the existence of light sterile neutrinos could be derived, however. As a first societal application we quantify how antineutrinos could be used for the Plutonium Management and Disposition Agreement.

citation-role summary

background 1

citation-polarity summary

fields

hep-ph 1

years

2026 1

verdicts

UNVERDICTED 1

roles

background 1

polarities

background 1

representative citing papers

Revival of the Reactor Antineutrino Anomaly

hep-ph · 2026-05-11 · unverdicted · novelty 4.0 · 2 refs

The reactor antineutrino anomaly is revived to 2.2 sigma with the 2023 flux calculation, showing 3.8 sigma tension with gallium data that drops to 1.3 sigma when gallium uncertainties are enlarged.

citing papers explorer

Showing 1 of 1 citing paper.

  • Revival of the Reactor Antineutrino Anomaly hep-ph · 2026-05-11 · unverdicted · none · ref 47 · 2 links · internal anchor

    The reactor antineutrino anomaly is revived to 2.2 sigma with the 2023 flux calculation, showing 3.8 sigma tension with gallium data that drops to 1.3 sigma when gallium uncertainties are enlarged.