Shintake Monitor in ATF2: Performance Evaluation
classification
⚛️ physics.ins-det
hep-exphysics.acc-ph
keywords
beamerrormonitorshintakeevaluationperformancesourcessystematic
read the original abstract
The beam test for the Shintake monitor succeeded in measuring signal modulation with the laser interference fringe pattern in November 2009. We have studied the error sources, and evaluated the systematic error to be less than 30% for 1 minute measurements. This paper centers on the evaluation of the Shintake monitor performance through analyzing beam tests deta. Most systematic error sources are well understood, enabling accurate measurement of the beam size when it reaches 37 nm.
This paper has not been read by Pith yet.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.