pith. sign in

arxiv: 1103.1042 · v1 · pith:RPSOMWQKnew · submitted 2011-03-05 · ⚛️ physics.optics · physics.atom-ph

Optical frequency metrology with a Rb-stabilized ring-cavity resonator -- Study of cavity-dispersion errors

classification ⚛️ physics.optics physics.atom-ph
keywords cavityerrorsfrequencyopticalrb-stabilizedresonatorring-cavitytechnique
0
0 comments X
read the original abstract

We have developed a technique to measure the absolute frequencies of optical transitions by using an evacuated Rb-stabilized ring-cavity resonator as a transfer cavity. We study possible wavelength-dependent errors due to dispersion at the cavity mirrors by measuring the frequency of the same transition in the $D_2$ line of Cs at three cavity lengths. We find no discernable change in values within our error of 30 kHz. Our values are consistent with measurements using the frequency-comb technique and have similar accuracy.

This paper has not been read by Pith yet.

discussion (0)