pith. sign in

arxiv: 1208.2262 · v4 · pith:T7HKDHAUnew · submitted 2012-08-10 · 🧮 math.AP · physics.med-ph

A simple Fourier transform-based reconstruction formula for photoacoustic computed tomography with a circular or spherical measurement geometry

classification 🧮 math.AP physics.med-ph
keywords formulareconstructionfrequencyfunctiontomographycircularcomponentscomputed
0
0 comments X
read the original abstract

Photoacoustic computed tomography (PACT), also known as optoacoustic tomography, is an emerging imaging modality that has great potential for a wide range of biomedical imaging applications. In this Note, we derive a hybrid reconstruction formula that is mathematically exact and operates on a data function that is expressed in the temporal frequency and spatial domains. This formula explicitly reveals new insights into how the spatial frequency components of the sought-after object function are determined by the temporal frequency components of the data function measured with a circular or spherical measurement geometry in two- and three-dimensional implementations of PACT, respectively. The structure of the reconstruction formula is surprisingly simple compared with existing Fourier-domain reconstruction formulae. It also yields a straightforward numerical implementation that is robust and two orders of magnitude more computationally efficient than filtered backprojection algorithms.

This paper has not been read by Pith yet.

discussion (0)