pith. machine review for the scientific record.
sign in

arxiv: 1601.01557 · v1 · pith:YDMCNAZKnew · submitted 2016-01-07 · 📊 stat.AP

Quaternion-Valued Single-Phase Model for Three-Phase Power Systems

classification 📊 stat.AP
keywords modelharmonicquaternion-valuedsignalthree-phasealgorithmclarkedetect
0
0 comments X
read the original abstract

In this work, a quaternion-valued model is proposed in lieu of the Clarke's \alpha, \beta transformation to convert three-phase quantities to a hypercomplex single-phase signal. The concatenated signal can be used for harmonic distortion detection in three-phase power systems. In particular, the proposed model maps all the harmonic frequencies into frequencies in the quaternion domain, while the Clarke's transformation-based methods will fail to detect the zero sequence voltages. Based on the quaternion-valued model, the Fourier transform, the minimum variance distortionless response (MVDR) algorithm and the multiple signal classification (MUSIC) algorithm are presented as examples to detect harmonic distortion. Simulations are provided to demonstrate the potentials of this new modeling method.

This paper has not been read by Pith yet.

discussion (0)

Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.