Tuner control system of spoke012 SRF cavity for C-ADS injector I at IHEP

classification ⚛️ physics.acc-ph cs.SYhep-ex
keywords tunercavityc-adscontrolihepinjectorpeaksystem
0
0 comments X
read the original abstract

A new tuner control system of spoke superconducting radio frequency (SRF) cavity has been developed and applied to cryomodule I (CM1) of C-ADS injector I at IHEP. We have successfully implemented the tuner controllerfor the first time and achieved a cavity tuning phase error of 0.7degrees (about 4 Hz peak to peak) in the presence of electromechanical coupled resonance. This paper will present the preliminary experimental results based on the new tuner controller under proton beam commissioning.