Precision beam energy measurement by undulator radiation at MAMI
classification
⚛️ physics.ins-det
physics.acc-ph
keywords
methodenergymeasurementbeameffectsmamiabsoluteaccuracy
read the original abstract
A novel interferometric method for absolute beam energy measurement is under development at MAMI. At the moment, the method is tested and optimized at an energy of 195 MeV. Despite the very small statistical uncertainty of the method, systematic effects have limited the overall accuracy. Recently, a measurement has been performed dedicated to the evaluation of these effects. This report comprises a description of the method and results of the recent data taking period.