Stable Operation of AlGaN/GaN HEMTs at 400^circC in air for 25 hours
read the original abstract
In this letter, we report the operation of AlGaN/GaN HEMTs with Pd gates in air over a wide temperature range from 22$^\circ$C to 500$^\circ$C. The variation in the threshold voltage ($V_{th}$) is less than 1$\%$ over the entire temperature range. Moreover, a safe biasing region where the transconductance peak ($g_m$) occurs over the entire temperature range was observed, enabling high-temperature analog circuit design. Furthermore, the operation of the devices over 25 hours was experimentally studied, demonstrating the stability of the DC characteristics and $V_{th}$ at 400$^\circ$C. Finally, the degradation mechanisms of HEMTs at 500$^\circ$C over 25 hours of operation are discussed, and are shown to be associated with the 2DEG sheet density and mobility decrease.
This paper has not been read by Pith yet.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.