Pith. sign in

REVIEW

Echo Planar Time-Resolved Imaging (EPTI) with Subspace Reconstruction and Optimized Spatiotemporal Encoding

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 1911.00999 v1 pith:MQ73BX3I submitted 2019-11-04 eess.IV

classification eess.IV
keywords reconstructionencodingeptiproposedsubspacecaipiimagingtemporal-variant
verification ladder T0 review T1 audit T2 compute T3 formal
0 comments
read the original abstract

Purpose: To develop new encoding and reconstruction techniques for fast multi-contrast quantitative imaging. Methods: The recently proposed Echo Planar Time-resolved Imaging (EPTI) technique can achieve fast distortion- and blurring-free multi-contrast quantitative imaging. In this work, a subspace reconstruction framework is developed to improve the reconstruction accuracy of EPTI at high encoding accelerations. The number of unknowns in the reconstruction is significantly reduced by modeling the temporal signal evolutions using low-rank subspace. As part of the proposed reconstruction approach, a B0-update algorithm and a shot-to-shot B0 variation correction method are developed to enable the reconstruction of high-resolution tissue phase images and to mitigate artifacts from shot-to-shot phase variations. Moreover, the EPTI concept is extended to 3D k-space for 3D GE-EPTI, where a new temporal-variant of CAIPI encoding is proposed to further improve performance. Results: The effectiveness of the proposed subspace reconstruction was demonstrated first in 2D GESE EPTI, where the reconstruction achieved higher accuracy when compared to conventional B0-informed GRAPPA. For 3D GE-EPTI, a retrospective undersampling experiment demonstrates that the new temporal-variant CAIPI encoding can achieve up to 72x acceleration with close to 2x reduction in reconstruction error when compared to conventional spatiotemporal-CAIPI encoding. In a prospective undersampling experiment, high-quality whole-brain T2* and QSM maps at 1 mm isotropic resolution was acquired in 52 seconds at 3T using 3D GE-EPTI with temporal-variant CAIPI encoding. Conclusion: The proposed subspace reconstruction and optimized temporal-variant CAIPI encoding can further improve the performance of EPTI for fast quantitative mapping.

Discussion (0). Continue with ORCID to comment.

Pith tools