Pith. sign in

REVIEW

Dissecting Energy Consumption of NB-IoT Devices Empirically

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2004.07127 v2 pith:UM7MBATF submitted 2020-04-15 cs.NI

classification cs.NI
keywords energyconsumptiondevicesnb-iotparametersconfigurationoperatorsaffected
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

3GPP has recently introduced NB-IoT, a new mobile communication standard offering a robust and energy efficient connectivity option to the rapidly expanding market of Internet of Things (IoT) devices. To unleash its full potential, end-devices are expected to work in a plug and play fashion, with zero or minimal parameters configuration, still exhibiting excellent energy efficiency. We perform the most comprehensive set of empirical measurements with commercial IoT devices and different operators to date, quantifying the impact of several parameters to energy consumption. Our campaign proves that parameters setting does impact energy consumption, so proper configuration is necessary. We shed light on this aspect by first illustrating how the nominal standard operational modes map into real current consumption patterns of NB-IoT devices. Further, we investigate which device reported metadata metrics better reflect performance and implement an algorithm to automatically identify device state in current time series logs. Then, we provide a measurement-driven analysis of the energy consumption and network performance of two popular NB-IoT boards under different parameter configurations and with two major western European operators. We observed that energy consumption is mostly affected by the paging interval in Connected state, set by the base station. However, not all operators correctly implement such settings. Furthermore, under the default configuration, energy consumption in not strongly affected by packet size nor by signal quality, unless it is extremely bad. Our observations indicate that simple modifications to the default parameters settings can yield great energy savings.

Discussion (0). Continue with ORCID to comment.

Pith tools