REVIEW
The Efficacy of Microaneurysms Detection With and Without Vessel Segmentation in Color Retinal Images
Not yet reviewed by Pith; the record is open.
This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.
SPECIMEN: schema-true, not a live event
T0 review · schema-true
One-sentence machine reading of the paper's core claim.
pith:XXXXXXXX · record.json · timestamp
read the original abstract
Computer-Aided Diagnosis systems are required to extract suitable information about retina and its changes. In particular, identifying objects of interest such as lesions and anatomical structures from the retinal images is a challenging and iterative process that is doable by image processing approaches. Microaneurysm (MAs) are one set of these changes caused by diabetic retinopathy (DR). In fact, MAs detection is the main step for the identification of DR in the retinal images analysis. The objective of this study is to apply an automated method for the detection of MAs and compare the results of detection with and without vessel segmentation and masking either in the normal or abnormal image. The steps for detection and segmentation are as follows. In the first step, we did preprocessing, by using top-hat transformation. Our main processing was included applying Radon transform, to segment the vessels and masking them. At last, we did the MAs detection step using a combination of Laplacian-of-Gaussian and Convolutional Neural Networks. To evaluate the accuracy of our proposed method, we compare the output of our proposed method with the ground truth that collected by ophthalmologists. With vessel segmentation, our algorithm found a sensitivity of more than 85% in the detection of MAs with 11 false-positive rates per image for 100 color images in a local retinal database and 20 images of a public dataset (DRIVE). Also without vessel segmentation, our automated algorithm finds a sensitivity of about 90% in the detection of MAs with 73 false positives per image for all 120 images of two databases. In conclusion, with vessel segmentation, we have acceptable sensitivity and specificity, as a necessary step in some diagnostic algorithm for retinal pathology.
Discussion (0). Continue with ORCID to comment.