Pith. sign in

REVIEW

750 MHz radio frequency quadrupole with trapezoidal vanes for carbon ion therapy

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2007.10739 v2 pith:Q66A2TP4 submitted 2020-07-21 physics.acc-ph

classification physics.acc-ph
keywords beamcarbondesigntherapydynamicsfrequencyquadrupoleradio
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

High-frequency linear accelerators are very suitable for carbon ion therapy, thanks to the reduced operational costs and the high beam quality with respect to synchrotrons, which are presently the only available technology for this application. In the framework of the development of a new linac for carbon ion therapy, this article describes the design of a compact 750 MHz Radio Frequency Quadrupole (RFQ) with trapezoidal vanes. A new semi-analytic approach to design the trapezoidal-vane RFQ is introduced together with the relevant beam dynamics properties. The RFQ is split into two decoupled rf cavities, both of which make use of a novel dipole detuning technique by means of length adjustment. The splitting is described both from the rf and the beam dynamics point of view. The paper concludes with the rf design of the full structure, including maximum surface field and thermal studies.

Discussion (0). Continue with ORCID to comment.