The Evaluation of Mechanical Properties of LB650 Cavities
Reviewed by Pithpith:LHNMVIC3open to challenge →
classification
physics.acc-ph
keywords
cavitiesmechanicaltestcavityheatlb650transportationbases
read the original abstract
The PIP-II project's LB650 cavities could potentially be vulnerable to mechanical deformation because of the geometric shape of the cavity due to reduced beta. The mechanical property of the niobium half-cell was measured following various heat treatments. The 5-cell cavities were tested in a controlled drop test fashion and the real-world road test. The result showed that the 900 $\deg$C heat treatment was compatible with cavity handling and transportation during production. The test provides the bases of the transportation specification and shipping container design guidelines.
This paper has not been read by Pith yet.
discussion (0)
Sign in with ORCID, Apple, or X to comment. Anyone can read and Pith papers without signing in.