Pith. sign in

REVIEW

Adapted Swin Transformer-based Real-Time Plasma Shape Detection and Control in HL-3

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2407.14232 v1 pith:GNQ4RFVJ submitted 2024-07-19 physics.plasm-ph

classification physics.plasm-ph
keywords plasmashapecontrolmodelfeedbackmagneticreal-timeswin
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

In the field of magnetic confinement plasma control, the accurate feedback of plasma position and shape primarily relies on calculations derived from magnetic measurements through equilibrium reconstruction or matrix mapping method. However, under harsh conditions like high-energy neutron radiation and elevated temperatures, the installation of magnetic probes within the device becomes challenging. Relying solely on external magnetic probes can compromise the precision of EFIT in determining the plasma shape. To tackle this issue, we introduce a real-time, non-magnetic measurement method on the HL-3 tokamak, which diagnoses the plasma position and shape via imaging. Particularly, we put forward an adapted Swin Transformer model, the Poolformer Swin Transformer (PST), to accurately and fastly interpret the plasma shape from the Charge-Coupled Device Camera (CCD) images. By adopting multi-task learning and knowledge distillation techniques, the model is capable of robustly detecting six shape parameters under disruptive conditions such as a divertor shape and gas injection, circumventing global brightness changes and cumbersome manual labeling. Specifically, the well-trained PST model capably infers R and Z within the mean average error below 1.1 cm and 1.8 cm, respectively, while requiring less than 2 ms for end-to-end feedback, an 80 improvement over the smallest Swin Transformer model, laying the foundation for real-time control. Finally, we deploy the PST model in the Plasma Control System (PCS) using TensorRT, and achieve 500 ms stable PID feedback control based on the PST-computed horizontal displacement information. In conclusion, this research opens up new avenues for the practical application of image-computing plasma shape diagnostic methods in the realm of real-time feedback control.

Discussion (0). Continue with ORCID to comment.

Pith tools