The CRILIN calorimeter: gamma radiation resistance of crystals and SiPMs
read the original abstract
The Crilin calorimeter is a semi-homogeneous calorimetric system based on Lead Fluoride (PbF$_2$) crystals with UV-extended Silicon Photomultipliers (SiPMs) proposed for the Muon Collider. This study investigates the radiation resistance of crystals and SiPMs, subjected to 10 kGy gamma irradiation, equivalent to a 10-year service life in the Muon Collider. Our findings indicate that while PbF$_2$ crystals exhibit a decrease in transmittance post-irradiation with partial recovery over time, the alternative PbWO$_4$-Ultra Fast (PWO-UF) demonstrates exceptional radiation hardness, maintaining stable transmittance. SiPMs showed an increase in dark current and breakdown voltage post-irradiation, with less degradation observed in the SiPM biased during the exposure to radiation compared to the unbiased component. These results underscore the viability of PbF$_2$ for radiation-tolerant calorimeters, though improvements in production homogeneity are needed. The superior performance of PWO-UF crystals suggests they are a promising alternative for high-radiation applications, but their higher cost must be carefully considered.