Pith. sign in

REVIEW

Personalizing the meshed SPL/NAC Brain Atlas for patient-specific scientific computing using SynthMorph

Not yet reviewed by Pith; the record is open.

This paper has not been read by Pith yet. Machine review is queued; the pith claim, tier, and objections will appear here once it completes.

SPECIMEN: schema-true, not a live event

T0 review · schema-true

One-sentence machine reading of the paper's core claim.

pith:XXXXXXXX · record.json · timestamp

arxiv 2503.00931 v1 pith:YBGOFLOY submitted 2025-03-02 cs.CE

classification cs.CE
keywords brainmethodanatomicalcomputationalmeshpatient-specificpersonalizedsynthmorph
verification ladder T0 review T1 audit T2 compute T3 formal

Signed reviews

No signed human review yet.

0 comments
read the original abstract

Developing personalized computational models of the human brain remains a challenge for patient-specific clinical applications and neuroscience research. Efficient and accurate biophysical simulations rely on high-quality personalized computational meshes derived from patient's segmented anatomical MRI scans. However, both automatic and manual segmentation are particularly challenging for tissues with limited visibility or low contrast. In this work, we present a new method to create personalized computational meshes of the brain, streamlining the development of computational brain models for clinical applications and neuroscience research. Our method uses SynthMorph, a state-of-the-art anatomy-aware, learning-based medical image registration approach, to morph a comprehensive hexahedral mesh of the open-source SPL/NAC Brain Atlas to patient-specific MRI scans. Each patient-specific mesh includes over 300 labeled anatomical structures, more than any existing manual or automatic methods. Our registration-based method takes approximately 20 minutes, significantly faster than current state-of-the-art mesh generation pipelines, which can take up to two hours. We evaluated several state-of-the-art medical image registration methods, including SynthMorph, to determine the most optimal registration method to morph our meshed anatomical brain atlas to patient MRI scans. Our results demonstrate that SynthMorph achieved high DICE similarity coefficients and low Hausdorff Distance metrics between anatomical structures, while maintaining high mesh element quality. These findings demonstrate that our registration-based method efficiently and accurately produces high-quality, comprehensive personalized brain meshes, representing an important step toward clinical translation.

Discussion (0). Continue with ORCID to comment.